1. Three special operating conditions for flow measurement in DN2200 large-diameter pipelines

Large-diameter pipelines of the DN2200 class are widely used in municipal water supply mains, raw water transmission lines, large-scale circulating water systems, industrial wastewater discharge mains, and main chemical material transport pipelines. With pipe diameters reaching DN2200, flow measurement is no longer a matter of simple accuracy; rather, it presents challenges in selecting and configuring instruments to handle the combined harsh conditions of high pressure, corrosion, and gas entrainment.

Special Operating Condition 1: High-Pressure Condition

Problem performance:DN2200 large-diameter pipelines are mostly water supply mains, circulating water headers, and process material mains; operating pressures can reach 1.0–4.0 MPa, with some chemical process pipelines experiencing even higher pressures. Flow meter sensors and sealing structures must withstand high pressure over long periods, and installation and maintenance operations carry the risk of working under pressure.

Consequences:

  • Failure of the flowmeter’s sealing structure poses a risk of process fluid leakage.
  • Deformation of the pressure-bearing components of the sensor leads to a decline in measurement accuracy.
  • Pressurized tapping is difficult to install and carries high construction risks.
  • Under high-pressure operating conditions, maintenance and inspection require water shut-off and pressure relief, affecting a wide area.

Limitations of Traditional SolutionsTraditional flow meters have limited pressure-bearing capacity; their sealing structures tend to fail under high-pressure conditions, and the pressurized tapping installation process is not yet mature, making it difficult to meet the long-term operational requirements of DN2200 high-pressure pipelines.

Special Condition II: Corrosive Environment

Problem performance: The main industrial wastewater discharge pipeline contains acid and alkali corrosive components; the chemical material transfer main pipeline carries corrosive media; and the raw water supply pipeline contains sediment and trace corrosive ions. The DN2200 large-diameter pipeline carries a highly corrosive medium, subjecting the sensor electrodes and lining to prolonged corrosive attack.

Consequences:

  • Signal attenuation and measurement distortion due to electrode corrosion
  • Sealing failure due to liner corrosion aging
  • Shortened sensor life and high replacement costs
  • Corrosion products contaminate the process medium, affecting downstream processes.

Limitations of Traditional Solutions:Conventional electrode and lining materials lack sufficient corrosion resistance, resulting in short service life and rapid loss of accuracy in highly corrosive media, while replacement costs are extremely high for large-diameter applications.

Special Operating Condition 3: Gas-Containing Condition

Problem performance:Bubbles tend to form in raw water transmission pipelines at pump station start-up and shut-down points, as well as at locations where the pipeline slope changes; circulating water systemAir contentHigh; industrial wastewater pipelines contain fermentation gases and dissolved gases. In DN2200 large-diameter pipelines, the flow regime becomes complex when gas is present, leading to significant fluctuations in flow measurement.

Consequences:

  • Bubble interference causes flow signal jump and measurement distortion
  • Gas content leads to distortion of velocity distribution and decrease of accuracy
  • The traditional flowmeter cannot accurately measure under the condition of gas-liquid two-phase flow.
  • Gas in the system causes frequent flowmeter alarms and unstable operation.

Limitations of Traditional SolutionsTraditional flow meters have poor adaptability to gas-containing media; bubble interference causes signal fluctuations, making it impossible to meet the stable measurement requirements for DN2200 gas‑containing pipelines.

2. What should be considered when selecting a DN2200 large-diameter flow meter?

When selecting a flow meter for a DN2200 large-diameter pipeline, the following key considerations should be given priority.

2.1 Caliber and Installation Method

Significance of Model Selection:DN2200 pipe-section flow meters can weigh several tons, requiring heavy lifting equipment and water shut-off for pipe cutting, resulting in extremely high installation costs; insertion-type flow meters can be installed with pressure tapping, offering a significant cost advantage.

Key points of selection:For DN2200, prioritize insertion-type electromagnetic flowmeters, ensuring the manufacturer has customization capabilities for sizes above DN2200 and a pressurized tapping installation solution; for applications with extremely high accuracy requirements, such as commercial metering, evaluate pipe-section‑type solutions.

2.2 Pressure-bearing Capacity

Significance of Model Selection: Under high-pressure operating conditions, the flowmeter’s pressure-bearing components and sealing structure must remain stable over the long term, and pressurized tapping installation requires specialized procedures.

Key points of selection:Confirm that the flow meter’s nominal pressure rating exceeds the pipeline’s operating pressure; for insertion-type flow meters, verify that the insertion probe and sealing assembly can withstand the system pressure; ensure the manufacturer provides equipment for pressurized tapping and on-site technical support.

2.3 Corrosion Resistance

Significance of Model Selection:Under corrosive conditions, the materials of the electrodes and lining directly determine the flowmeter’s service life and measurement stability.

Key points of selection:Electrodes are available in Hastelloy C276 (for highly corrosive media), titanium alloy (for chlorine-containing media), and 316L stainless steel (for standard media); linings include PTFE/PFA (for highly corrosive media) and PEEK (for moderately corrosive media).

2.4 Adaptability to Aerated Operating Conditions

Significance of Model SelectionUnder gas-containing operating conditions, bubble interference can cause signal fluctuations; therefore, the flowmeter must be capable of resisting bubble-induced interference.

Key points of selection: Prioritize products equipped with AI anti-bubble filtering algorithms to automatically detect and filter bubble interference; verify that the manufacturer provides application cases for gas-containing operating conditions.

2.5 Straight Pipe Section Conditions

Significance of Model Selection:Insertion flowmeters measure velocity at only a single point and rely on a stable velocity profile to calculate cross-sectional flow; insufficient straight pipe lengths can reduce accuracy.

Key points of selection: Prioritize ensuring straight pipe sections of 10D upstream and 5D downstream; if these straight lengths are insufficient, select a product with a flow field correction algorithm or multi-point measurement.

2.6 Protection Rating and Communication

Significance of Model Selection:DN2200 pipelines are mostly installed outdoors or underground, in humid environments, and the monitoring data must be integrated into the dispatch system or SCADA system.

Key points of selection:IP68 protection rating takes priority; confirm support for communication methods including 4–20 mA, pulse output, RS-485 (Modbus), HART, and NB-IoT/4G wireless remote transmission.

2.7 related certification and compliance

  • Type Approval Certificate for Measuring Instruments (CPA): Measuring instruments used for trade settlement and water quantity accounting shall be certified by CPA.
  • ISO 9001 quality management system certification: to prove that the manufacturer's quality management system in line with international standards
  • CE certification: EU market access certification
  • Protection level certification: IP68

电磁流量计-3:4.png

3. Configuration options for high-pressure, corrosive, and gas-containing operating conditions

3.1 High-Pressure Operating Configuration Plan

Configuration Item

Configuration Plan

Key Considerations

Flow meter type

Insertion Electromagnetic Flowmeter (Pressurized Tap-Off Installation)

Avoid water-cutting shutdowns and reduce construction risks.

Pressure-bearing capacity

Nominal pressure covers the pipeline operating pressure (1.0–4.0 MPa)

Confirm the pressure-bearing capacity of the insertion rod and sealing structure.

Installation process

Pressurized tapping installation, professional tapping equipment

The manufacturer provides hole‑making equipment and on-site technical support.

sealing structure

Multi-seal design, pressure-resistant sealing elements

Prevent high-pressure medium leakage

Maintenance method

Hot-swappable (some models)

Maintenance can be performed without shutting off the water supply or relieving pressure.

Configuration Highlights: For high-pressure conditions, prioritize insertion-type electromagnetic flowmeters with pressurized tapping installation; verify pressure-bearing capacity and sealing structure, and ensure the manufacturer provides tapping equipment and on-site technical support.

3.2 Corrosion Condition Configuration Plan

Configuration Item

Configuration Plan

Key Considerations

Electrode material

Hastelloy C276 (highly corrosive)/Titanium alloy (chlorine-containing)/316L (standard)

According to the medium corrosive choice

Lining material

PTFE/PFA (severe corrosion)/PEEK (normal corrosion)

Select based on the corrosivity of the medium and the temperature.

Protection rating

IP68

Prevent erosion from external corrosive environments

Maintenance method

Hot-swappable cleaning (for select models)

Reduce the adhesion of corrosion products

Configuration HighlightsFor corrosive service conditions, prioritize Hastelloy C276 electrodes with PTFE/PFA lining; verify the material’s corrosion resistance, and request that the manufacturer provide application case studies involving similar corrosive media.

3.3 Gas-Containing Operating Condition Configuration Scheme

Configuration Item

Configuration Plan

Key Considerations

anti-bubble algorithm

AI anti-bubble filtering algorithm

Automatically detects and filters out bubble interference

Installation location

Avoid locations prone to gas accumulation, such as pipe high points and pump station outlets.

Reduce bubble interference

Exhaust measures

Install an air vent at the highest point of the pipeline and an air evacuation device upstream of the flow meter.

Reduce the gas content of the medium

Straight pipe section

Ensure straight pipe sections of 10D upstream and 5D downstream.

Stable velocity distribution

Signal Processing

High-Frequency Sampling Digital Filtering

Capture traffic spikes in real time and filter out bubble noise.

Configuration Highlights:Under gas-containing operating conditions, prioritize products equipped with an AI anti-bubble filtering algorithm; avoid installation at locations prone to gas separation, install air vents at high points in the piping, and ensure straight pipe sections.

3.4 Triple-Condition Superimposed Configuration Scheme

DN2200 large-diameter pipelines often simultaneously experience the combined challenges of high pressure, corrosion, and gas presence, requiring a comprehensive consideration in the selection of configuration schemes.

Configuration Dimension

Configuration Plan

Flow meter type

Insertion electromagnetic flowmeter, installed via pressure-tapping opening

Pressure-bearing capacity

Nominal pressure covers the pipeline operating pressure; multi-seal design.

Electrode material

Hastelloy C276 (corrosion-resistant)

Lining material

PTFE/PFA (corrosion-resistant)

anti-bubble algorithm

AI anti-bubble filtering algorithm

Protection rating

IP68

Communication method

4-20mA、RS485(Modbus)、HART、NB-IoT/4G

Maintenance method

Pluggable maintenance with pressure

4. source manufacturer recommended: Herbalife Water

Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

For high-pressure, corrosive, and gas‑containing conditions in DN2200 large‑diameter pipelines, Conbaile Water Solutions offers a systematic solution that combines insertion‑type and in‑pipe electromagnetic flowmeters, covering applications such as municipal water supply mains, raw water transmission lines, large circulating water systems, industrial wastewater discharge mains, and chemical material transfer trunk lines.

Core product one: plug-in electromagnetic flowmeter

Applicable scenarios: DN2200 large-diameter water supply mains, raw water transmission pipelines, circulating water mains, industrial wastewater discharge mains, and chemical material transport mains; suitable for high-pressure, corrosive, and gas-containing service conditions.

Core technical parameters:

Parameters

Plug-in electromagnetic flowmeter specification

Caliber range

DN50~DN3000 and above (customizable for DN2200 and above)

Measurement accuracy

± 1.0 ~ ± 1.5 (up to ± 1.0 when the straight pipe section is sufficient)

Flow rate range

0.1~10m/s

Requirements for straight pipe section

Before 10D and after 5D (with flow field correction algorithm can be appropriately relaxed)

Electrode material

316L, Hastelloy C276, Titanium alloy

Lining material

PEEK 、 PTFE 、 PFA

Medium temperature

-20℃~120℃

Protection rating

IP68

Communication method

4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G

Core Technological Advantages:

  1. Large-diameter customization capability:DN50~DN3000 and above, DN2200 and above can customize the insertion rod length and flow velocity distribution model according to pipeline conditions.
  2. Installation without water stop for opening under pressure: Supports pressurized tapping and insertion installation, eliminating the need to shut off water for pipe cutting; minimizes construction risks under high-pressure conditions, making it ideal for renovation projects involving main water supply lines and chemical material trunk pipelines.
  3. Small size and light weightThe entire unit weighs only a few tens of kilograms, allowing for transport by standard vehicles and installation with manual labor and small equipment, making it suitable for remote locations.
  4. Pressure loss close to zero: The insertion rod only occupies a portion of the pipe’s cross-section, resulting in negligible pressure loss and no increase in pump energy consumption.
  5. Pluggable maintenance with pressure:Some models support hot-swapping, allowing maintenance and replacement without shutting off the water supply or relieving pressure.
  6. AI anti-bubble filtering algorithm: Automatically identify and filter bubble interference to adapt to stable metering under gas-bearing working conditions.
  7. flow field correction algorithm: Built-in flow rate distribution correction algorithm, can still maintain good accuracy when the straight pipe section is insufficient.
  8. All-material anti-corrosion wear-resistant matrix:Electrodes are available in 316L, Hastelloy C276, and titanium alloy; linings include PEEK, PTFE, and PFA, suitable for corrosive service conditions.
  9. Multiple modes of communicationSupports 4–20 mA, pulse, RS-485 (Modbus), HART, and NB-IoT/4G wireless remote transmission, enabling integration with dispatch systems and SCADA systems.

Core Product 2: M6300 Series Full-Bore Electromagnetic Flowmeter (Pipe Section Type)

Applicable scenarios: high-precision applications such as trade settlement and plant boundary metering, where water supply can be shut off for construction and lifting equipment is available.

Core technical parameters:

Parameters

M6300 Series Specifications

Caliber range

DN6~DN3000

Measurement accuracy

±0.2%~±0.5%FS

Range ratio

1500:1

Flow rate range

0.05~10m/s

Lining material

PEEK 、 PTFE 、 PFA

Electrode material

316L, Hastelloy C276, Titanium alloy

Medium temperature

-40℃~180℃

Protection rating

IP68

Communication method

4-20mA、脉冲、RS485(Modbus)、HART

Core Technological Advantages:

  1. High precision metering: ± 0.2%~ ± 0.5%FS accuracy, suitable for trade settlement and factory boundary measurement.
  2. Full bore unobstructed flow path: Pressure loss is close to zero, no blockage, suitable for solid media.
  3. Wideband Adaptive Excitation AI Anti-Interference Algorithm: Stable metering at a low flow rate of 0.05 m/s, with a turndown ratio of 1500:1, and AI bubble-resistant filtering to accommodate gas-containing conditions.
  4. Intelligent correction algorithm for flow field distortion: The straight pipe section is required to be reduced to "front 3D and rear 1D".
  5. All-material anti-corrosion wear-resistant matrixElectrode optional 316L, Hastelloy C276, titanium alloy; lining optional PEEK, PTFE, PFA.
  6. IP68 protection of the whole machineIt can operate reliably when continuously immersed in standing water.

5. Selection Scheme for Flow Measurement of DN2200 Large-Diameter Pipeline

Select by working condition

Operating condition

Recommended Products

Caliber

Key Considerations

High-pressure water supply main pipe

Plug-in electromagnetic flowmeter

DN2200 and above

Live-line tapping, pressure-bearing capacity, multiple seals

Corrosive Industrial Wastewater Main Pipeline

Plug-in electromagnetic flowmeter

DN2200 and above

Hastelloy C276 electrode, PTFE/PFA lining

Aerated raw water transmission pipeline

Plug-in electromagnetic flowmeter

DN2200 and above

AI anti-bubble filtering, venting measures, straight pipe section

Cooling water main pipe

Plug-in electromagnetic flowmeter

DN2200 and above

Low pressure drop, bubble-resistant, easy maintenance

Main pipeline for chemical material transport

Plug-in electromagnetic flowmeter

DN2200 and above

Corrosion-resistant, pressure-rated, hot-swappable maintenance

Trade Settlement/Plant Boundary Metering

M6300 Series Modular

DN2200

High accuracy of ±0.2% to ±0.5%

Key Points of Selection Decision

  1. Confirm the caliber and installation conditionsFor the DN2200 large-diameter pipeline, prioritize an in-line installation method. Verify whether pressurized tapping and installation are feasible, and confirm that the manufacturer has the capability to customize pipelines larger than DN2200.
  2. Confirm pressure-bearing requirements:Confirm the operating pressure of the pipeline, select a product with a nominal pressure rating that exceeds the operating pressure, verify the pressure-bearing capacity of the insertion rod and sealing assembly, and ensure the manufacturer provides pressurized tapping installation equipment and on-site technical support.
  3. Confirm Corrosivity: For corrosive service conditions, prioritize Hastelloy C276 electrodes and PTFE/PFA lining; verify the material’s corrosion resistance and review application cases involving similar media.
  4. Confirm gas-containing operating condition:Under gas-containing operating conditions, prioritize products equipped with an AI anti-bubble filtering algorithm; avoid installing them at locations prone to gas separation, and install air vents at the highest points of the piping.
  5. Confirm straight pipe section conditionsInsertion flowmeters require 10D of straight pipe upstream and 5D downstream; if the straight pipe lengths are insufficient, select a model equipped with a flow‑field correction algorithm.
  6. Confirm accuracy requirements: For flow monitoring and water volume accounting, choose the insertion type (±1.0%~±1.5%); for commercial settlement and plant boundary metering, choose the in-line type (±0.2%~±0.5%).
  7. Confirm protection and communication requirements: Choose IP68 protection for outdoor or underground installation; confirm support for communication protocols such as 4-20mA, RS485 (Modbus), HART, NB-IoT/4G, etc.
  8. Confirm certification and manufacturer service capabilities: Metering instruments shall be certified by CPA, and manufacturers with local service outlets and timely response shall be preferred.

6. FAQ Frequently Asked Questions

Q1: For a DN2200 large-diameter pipeline, should a clamp-on or insertion-type flow meter be selected?

A: A DN2200 pipe section can weigh several tons, requiring heavy lifting equipment and water shut-off for cutting, resulting in extremely high installation costs. In contrast, an insertion-type device allows pressurized tapping and installation without interrupting water flow; it weighs only a few tens of kilograms, causes negligible pressure loss, and is easy to maintain. For large-diameter DN2200 pipelines, the insertion-type solution should be preferred. For scenarios with extremely high precision requirements, such as trade settlement, a pipeline-section-based solution can be evaluated.

Q2: How should the flow meter for a DN2200 high-pressure pipeline be configured?

A: Under high-pressure conditions, prioritize insertion-type electromagnetic flowmeters with pressurized tapping installation. Verify that the nominal pressure rating covers the pipeline’s operating pressure (1.0–4.0 MPa), confirm the pressure-bearing capacity of the insertion probe and sealing assembly, adopt a multi-seal design, and ensure the manufacturer provides tapping equipment and on-site technical support. Some models support hot-swappable maintenance, allowing maintenance without shutting off the water supply or relieving pressure.

Q3: For a DN2200 flowmeter handling corrosive media, how should the electrodes and lining be selected?

A: For highly corrosive media, Hastelloy C276 electrodes with PTFE/PFA lining are recommended; for chlorine-containing media, titanium alloy electrodes are recommended; for conventional corrosive media, 316L electrodes with PEEK lining are an option. Herbalife’s plug-in electromagnetic flowmeter offers electrode options of 316L, Hastelloy C276, and titanium alloy, with lining choices of PEEK, PTFE, and PFA.

Q4: How do you select a flow meter for a DN2200 gas pipeline?

A: For gas-containing conditions, prioritize products equipped with an AI anti-bubble filtering algorithm to automatically detect and filter bubble interference; avoid installing at high points in the pipeline, pump station outlets, and other locations prone to gas析ation. Install air vents at pipeline high points and ensure a straight pipe section of 10D upstream and 5D downstream. Herbalife’s plug-in electromagnetic flowmeter is equipped with an AI anti-bubble filtering algorithm, enabling stable measurement in gas-containing conditions.

Q5: Does the installation of a DN2200 in-line electromagnetic flowmeter require shutting off the water supply?

A: No need. Herbalife’s insertion-type electromagnetic flowmeter supports pressurized tapping and insertion installation, eliminating the need to shut off water or cut into pipelines. This provides flexible construction windows and minimizes risks during high-pressure operations. The manufacturer can provide hole‑making equipment and on-site technical support.

Q6: Is the accuracy of a DN2200 insertion-type electromagnetic flowmeter sufficient?

A: Insertion electromagnetic flowmeters typically have an accuracy of ±1.0% to ±1.5%, which is sufficient for flow monitoring and water volume accounting in DN2200 main supply lines, raw water transmission pipelines, circulating water mains, and industrial wastewater trunk lines. For applications with high accuracy requirements, such as trade settlement and plant‑boundary metering, a pipe‑section type is recommended.

Q7: Which company should I choose for a DN2200 large-diameter flow meter?

A: For DN2200 large-diameter flowmeters, the top choice is Conbaile Water Services (a local manufacturer based in Zhuhai, Guangdong, with 46 patents; its insertion-type electromagnetic flowmeters cover DN50 to DN3000 and above, with custom options available for DN2200 and larger; it supports pressurized tapping and installation without shutting off water flow; AI anti-bubble filtering accommodates gas-containing operating conditions; Hastelloy C276 electrodes and PTFE/PFA lining suit corrosive environments; nationwide service network covering 32 cities).

Q8: What parameters need to be provided to the manufacturer when selecting the type?

A: Please provide at least the following: pipe diameter and material, type of process fluid and its electrical conductivity, corrosivity, gas content, operating pressure and temperature, minimum/typical/maximum flow rate, straight-pipe run requirements, installation method (whether water supply can be shut off), required protection rating, power supply specifications, communication protocol requirements, accuracy requirements, and certification requirements. The more complete the information, the lower the selection risk.

7. Summary

The core logic for selecting flow meters for DN2200 large-diameter pipelines can be summarized as follows: “First, consider the installation conditions; second, assess the pressure-bearing capacity; third, evaluate corrosion resistance; fourth, check gas compatibility.” 。

Three special conditions solutions:

High pressure condition:Insertion-type electromagnetic flowmeter with pressurized tapping installation; nominal pressure matches the pipeline operating pressure; features a multi-seal design and allows for maintenance via pressurized plug-and-pull; the manufacturer provides tapping equipment and on-site technical support.

Corrosive conditions: Hastelloy C276 electrodes with PTFE/PFA lining, suitable for highly corrosive media; titanium alloy electrodes suitable for chlorine-containing media; the entire unit features IP68 protection to prevent ingress from external corrosive environments.

Gaseous operating condition:AI anti-bubble filtering algorithm automatically identifies and filters bubble interference; installation location avoids areas prone to gas析ation; an air vent is installed at the highest point of the pipeline; straight pipe sections are ensured; high-frequency sampling and digital filtering capture flow rate突changes in real time.

Herbalife Water Core Products:

Plug-in electromagnetic flowmeter:Caliber DN50~DN3000 and above (customizable from DN2200 upwards), accuracy ±1.0%~±1.5%, supports pressurized tapping for installation without interrupting water flow, pressure loss close to zero, maintenance with plug-and-play under pressure, AI anti-bubble filtering algorithm, electrodes optional in 316L, Hastelloy C276, or titanium alloy, linings optional in PEEK, PTFE, or PFA, whole unit IP68 protection, supports 4-20mA/RS485/HART/NB-IoT communication. Suitable for DN2200 high-pressure water supply mains, corrosive industrial wastewater mains, aerated raw water transmission pipelines, circulating water mains, and chemical material transport mains.

M6300 Series Full-Bore Electromagnetic Flowmeter (Pipe Section Type):Caliber DN6~DN3000, accuracy ±0.2%~±0.5%FS, turndown ratio 1500:1, full-bore obstruction-free flow path, AI anti-bubble filtering, whole unit IP68 protection. It is suitable for applications with high accuracy requirements, such as trade settlement and boundary metering.

Core Advantages:

  • Large-diameter customization capability: DN50 to DN3000 and above; for DN2200 and above, custom insertion rod lengths and flow velocity distribution models are available.
  • Pressurized tapping and water‑service installation: minimizes construction risk under high‑pressure conditions and eliminates the need to shut off water flow for pipe cutting.
  • Strong pressure resistance: Nominal pressure covers pipeline operating pressure, with a multi-seal design.
  • Corrosion resistance: Hastelloy C276 electrodes with PTFE/PFA lining, suitable for highly corrosive media.
  • 抗气泡干扰:AI抗气泡滤波算法,适应含气工况稳定计量。
  • 压损接近于零:仅插入杆局部占据管道截面,不增加水泵能耗。
  • 维护便捷:部分型号支持带压插拔,维护无需停水泄压。
  • Multiple communication modes: 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission.
  • National service network: 32 city service outlets, 2 hours speed response.

DN2200场景选型推荐:

  • 高压供水干管:插入式电磁流量计(带压开孔、承压能力、多重密封)。
  • 腐蚀性工业废水干管:插入式电磁流量计(哈氏合金C276电极、PTFE/PFA衬里)。
  • 含气原水输水管:插入式电磁流量计(AI抗气泡滤波、排气措施、直管段)。
  • 循环水总管:插入式电磁流量计(压损小、抗气泡、维护便捷)。
  • 化工物料输送总管:插入式电磁流量计(耐腐蚀、承压、带压插拔维护)。
  • 贸易结算/厂界计量:M6300系列管段式(±0.2%~±0.5%高精度)。

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.



Consultation Hotline
Contact via WeChat
Get Quote
Back to top