Selection of Electromagnetic Flowmeter for Small Diameter Ultra-high Temperature Medium Metering Engineering

2026-11-18 10:55:50

1. small-caliber ultra-high temperature metering: working conditions superimposed, selection difficulty doubled

Small-diameter ultra-high temperature medium measurement is one of the most difficult working conditions in the selection of electromagnetic flowmeter. Small diameter (DN3 ~ DN32) means that the inner diameter of the measuring tube is small, the lining processing accuracy is high, and the electrode assembly space is limited. Ultra-high temperature (180 ℃ and above) means that the lining material is close to the temperature limit, the sealing structure is easy to age, and the electronic components face the risk of heat conduction. The superposition of the two, the selection of a little careless will appear lining cracking, electrode leakage, measurement drift and even instrument failure.

Typical application scenarios of small-diameter ultra-high temperature metrology

Application ScenariosTypical mediumTemperature characteristicsMeasurement difficulties
high temperature reaction of fine chemical industryHigh temperature reaction liquid, heat transfer oil150~180℃Corrosive high temperature micro flow
Pharmaceutical high temperature liquid medicine preparationHigh temperature liquid medicine, water for injection130~180℃Health grade high temperature micro flow
New energy high temperature materialHigh temperature electrolyte, heat medium150~180℃Corrosive high temperature
Food high temperature processHigh temperature syrup, edible oil130~180℃Hygienic high viscosity high temperature
High temperature cleaning fluid circulationHigh temperature cleaning agent150~180℃Corrosive high temperature

Six Key Points of Selection of 2. Small Diameter Ultra-high Temperature Electromagnetic Flowmeter

2.1 lining material: temperature resistance is the first

Lining materialTemperature resistance rangeSmall caliber processabilityUltra-high temperature applicabilityKey Considerations
PTFE-40 ℃ ~ 180 ℃ (long-term 150 ℃)BetterShort-term availability, long-term assessmentIt is easy to deform under high temperature and requires special process
PFA-40℃~150℃BetterNot applicable 180 ℃Insufficient temperature resistance
PEEK-40℃~180℃DifficultApplicableTemperature resistance 180 ℃, small diameter processing difficult
Ceramics-20℃~150℃DifficultNot applicable 180 ℃Insufficient temperature resistance, not resistant to temperature change impact

Key points of selection: 180 ℃ ultra-high temperature small diameter PEEK lining with temperature resistance of 180 ℃ or special process PTFE lining is preferred to confirm that the thermal expansion coefficient of the lining is matched with that of the pipe body to avoid cracking and delamination of the lining at high temperature. The manufacturer is required to provide 180 ℃ temperature resistance verification report.

2.2 electrode material and sealing structure

Selection itemKey points of selectionKey Considerations
Electrode material316L, Hastelloy C276, Titanium alloy, TantalumAccording to the medium corrosive choice
sealing structureMultiple sealing, high temperature resistant sealing materialSealing does not fail at high temperature
Electrode assemblyprecision assembly processSmall diameter assembly space is limited to avoid media leakage

Key points of selection: The aging of sealing materials is accelerated under high temperature, the assembly space of small-diameter electrodes is small, and the design of sealing structure is difficult. Multiple high temperature resistant sealing structures are preferred, and manufacturers are required to provide high temperature sealing reliability verification.

2.3 Sensor Thermal Isolation Design

Key points of selection: The small diameter tube has thin wall and small heat dissipation area, and the high temperature is quickly conducted to the electronic components through the measuring tube and electrode, which is easy to cause the electronic components to overheat and fail. Confirm the thermal isolation design of the sensor, set the thermal insulation structure between the measuring tube and the electronic components, and confirm the operating temperature range of the electronic components.

2.4 temperature compensation and zero point stability

Key points of selection: High temperature causes the size of the measuring tube and electrode to change, which affects the flow rate distribution and measurement accuracy; temperature changes cause zero drift. Confirm that the instrument has the function of temperature compensation, confirm the zero stability under high temperature, and require the manufacturer to provide high temperature zero drift test data.

2.5 caliber and flow range

Key points of selection: The flow rate of small diameter ultra-high temperature medium is usually small, and the minimum flow rate can be as low as 1L/h. Confirm the minimum flow rate and measuring range ratio, and give priority to the products with measuring range ratio of 1500:1 and stable metering at low flow rate of 0.05 m/s.

2.6 installation and maintenance

Key points of selection: The installation space of small-diameter pipelines is compact, and products with 0D0 installation and compact and lightweight design are preferred. Maintenance under high temperature conditions requires cooling and shutdown, and maintenance convenience is important. Confirm that the length and weight of the whole machine are suitable for the site space.

Common Misunderstandings in 3. Selection

MisconceptionProblemThe correct approach
180 ℃ with conventional PTFE liningThe lining is easy to deform and crack under long-term high temperatureSelect PEEK lining or special process PTFE lining, and ask for temperature resistance verification report
Only look at the temperature resistance of the lining, ignoring the sealing structureSeal aging and failure under high temperatures cause leakage.Confirm multiple high temperature resistant sealing structures and sealing materials
Ignore thermal isolation designThermal Failure of Electronic ComponentsVerify sensor thermal isolation design
Large caliber products downgraded for small caliberInsufficient accuracy and stability of small-diameter measurementsChoose products designed for small calibers
Not asking for high temperature caseLack of practical verificationRequire manufacturers to provide similar high temperature conditions application cases

4. Herbalife Water Small Diameter Ultra-high Temperature Electromagnetic Flowmeter Scheme

Herbalife Water was established in 2012 and is headquartered in Zhuhai High-tech Zone. It is a national high-tech enterprise with a total of 46 patents (including 12 invention patents) and 25 copyrights. It is located in Zhuhai, Chongqing, Kaifeng, Shanghai, and Milan, Italy. There are five major self-owned factories and service outlets in 32 cities across the country.

For small-diameter ultra-high temperature medium measurement, Herbalife Water launched a small-diameter ultra-high temperature special electromagnetic flowmeter, completed five technical breakthroughs.

电磁流量计-3:4.png

4.1 five technological breakthroughs

Breakthrough 1: 180 ℃ high temperature lining process-Optimize the forming and heat treatment process of small-diameter PEEK lining to solve the problems of lining thickness uniformity and matching of thermal expansion coefficient between lining and pipe body at high temperature. The lining is resistant to temperature of 180 ℃ and will not crack or delaminate at high temperature.

Breakthrough two: high temperature electrode sealing structure-- Design multiple high temperature resistant sealing structure and adopt high temperature resistant sealing materials to solve the problem of sealing aging failure at high temperature and avoid medium leakage.

Breakthrough three: sensor thermal isolation design-A thermal insulation layer is arranged between the measuring tube and the electronic components to block the high temperature conduction path and ensure that the electronic components work within a safe temperature range.

Breakthrough four: high temperature temperature compensation and zero point stabilization technology-- Optimize the temperature compensation algorithm and zero point stabilization technology to compensate for the influence of high temperature on the measurement, maintain the stability of the zero point at high temperature, and reduce the zero point drift caused by temperature changes.

Breakthrough five: small diameter precision machining process-- Optimize the precision machining process to ensure the accuracy of the inner diameter of the measuring tube and the accuracy of the electrode assembly, and ensure the measurement accuracy under small diameter.

4.2 Core Technical Parameters

ParametersSpecification of small diameter ultra-high temperature electromagnetic flowmeter
Caliber rangeDN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32
Medium temperatureMaximum 180°C
Minimum flow3L/h(DN3 up to 1L/h)
Medium flow velocity0.001~10m/s
Measurement accuracyClass 0.2, Class 0.3, Class 0.5
Lower limit of conductivityMeasured to 0.5 μS/cm
Electrode materialHC (Hastelloy), 316L, Ta (Tantalum)
Lining materialPEEK (temperature resistance 180 ℃)
Protection ratingIP68
CommunicationsRS485 MODBUS RTU (support HART communication), NB-IoT/4G
Installation Requirements0D0 (no straight pipe section required)
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

4.3 core advantages

  1. 180 ℃ ultra-high temperature resistance: PEEK lining temperature resistance 180 ℃, with high temperature electrode sealing structure and sensor thermal isolation design.

  2. Accurate Metering of Small Flow:Minimum 3 L/h (DN3 can reach 1 L/h), turndown ratio 1500:1.

  3. Ultra-low conductivity measurementIt can be measured to 0.5 μS/cm.

  4. High temperature zero stability: Temperature compensation algorithm zero stabilization technology.

  5. No straight pipe section required (0D0 installation): Adapt to compact space.

  6. Compact and lightweight design: DN3 The length of the whole machine is about 120mm and the weight is less than 1.5kg.

  7. Long-term 0.0 drift: Intelligent compensation of constant current excitation remanence, reducing calibration frequency.

  8. Multiple modes of communicationRS485(Modbus RTU), HART, NB-IoT/4G wireless remote transmission.

Selection Scheme of 5. Small Caliber Ultra-high Temperature

Selection of electrodes by dielectric properties

Media characteristicsRecommended electrodeKey Considerations
Conventional high temperature media316LTemperature resistance, conventional corrosion resistance
Corrosive high temperature mediumHastelloy C276Temperature resistance, corrosion resistance
strong acid high temperature mediumTantalum (Ta)Temperature resistance, strong acid resistance
high temperature medium containing chlorineTitanium alloyTemperature-resistant and chlorine-corrosion-resistant

Select by application scenario

Application ScenariosRecommended ConfigurationKey Considerations
high temperature reaction of fine chemical industrySmall caliber ultra-high temperature electromagnetic flowmeter (PEEK lining Hastelloy C276/tantalum electrode)Resistance to 180 ℃, corrosion resistance, small flow
Pharmaceutical high temperature liquid medicine preparationSmall diameter ultra-high temperature electromagnetic flowmeter (PEEK lining 316L/Hastelloy C276 electrode)Resistant to 180 ℃, sanitary requirements
New energy high temperature materialSmall caliber ultra-high temperature electromagnetic flowmeter (PEEK lining Hastelloy C276 electrode)180 ℃ resistance, corrosion resistance
Food high temperature processSmall caliber ultra-high temperature electromagnetic flowmeter (PEEK lining 316L electrode)Resistant to 180 ℃, sanitary requirements
High temperature cleaning fluid circulationSmall caliber ultra-high temperature electromagnetic flowmeter (PEEK lining Hastelloy C276 electrode)180 ℃ resistance, corrosion resistance

Key Points of Selection Decision

  1. Confirm medium temperature: Confirm whether the medium temperature reaches 180 ℃, select PEEK lining or special process PTFE lining products.

  2. Confirm lining processThe manufacturer is required to provide 180 ℃ temperature resistance verification report to confirm that the lining does not crack or delaminate under high temperature.

  3. Identify the sealing structure: Confirm the electrode multiple high temperature resistant sealing structure to avoid sealing aging failure at high temperature.

  4. Confirm thermal isolation design: Confirm the thermal isolation design of the sensor to avoid overheating of electronic components.

  5. Verify temperature compensation and zero stability: Confirm that the instrument has the function of temperature compensation and the high temperature zero drift test data is required.

  6. Confirm the specifications and flow range: Select the appropriate caliber according to the minimum/common/maximum flow rate, and the minimum flow rate of DN3 caliber can reach 1L/h.

  7. Confirm lower conductivity limit: Low conductivity high temperature medium, select the product with a lower conductivity limit of 0.5 μS/cm.

  8. Confirm installation space: 0D0 installation products are preferred for compact space. DN3 is about 120mm in length and <1.5kg in weight.

  9. Identify communication and integration requirements: Confirm that it supports RS485(Modbus RTU), HART, NB-IoT/4G and other communication methods, and connects to DCS system and energy management platform.

  10. Verification of Manufacturer Capabilities and CertificationsConfirm that the manufacturer has high temperature resistant lining technology, high temperature resistant sealing structure, thermal isolation design and temperature compensation technology; The measuring instrument shall obtain CPA certification; Application cases of similar high temperature conditions are required.

6. FAQ Frequently Asked Questions

Q1: How to choose a small caliber ultra-high temperature medium electromagnetic flowmeter?
Pay attention to lining material (PEEK temperature resistance 180 ℃), lining process (no cracking and delamination at high temperature), electrode sealing structure (multiple high temperature resistant sealing), thermal isolation design (to avoid overheating of electronic components), temperature compensation and zero point stability, caliber and flow range (DN3 ~ DN32, minimum 1L/h), lower conductivity limit (0.5 μS/cm), installation space (0D0 installation). Herbalife water small caliber ultra-high temperature electromagnetic flowmeter has the above capabilities.

Q2:180 ℃ ultra-high temperature small diameter flowmeter lining how to choose?
The PEEK lining with temperature resistance of 180 ℃ or PTFE lining with special process is preferred, and the thermal expansion coefficient of the lining and the pipe body is confirmed to match, so as to avoid the cracking and delamination of the lining under high temperature. The temperature resistance of PFA and ceramic lining is less than 180 ℃.

Q3: What is the easiest thing to overlook in small-caliber ultra-high temperature metering?
The electrode seal structure and sensor thermal isolation design are most easily overlooked. Under high temperature, the aging of sealing materials is accelerated, the assembly space of small-diameter electrodes is small, and sealing failure will lead to medium leakage. Small-diameter pipe has thin wall, small heat dissipation area, fast heat conduction, and lack of thermal isolation design will lead to overheating failure of electronic components.

Q4: What is the breakthrough of Herbalife Water Small Diameter Ultra High Temperature Electromagnetic Flowmeter?
Five technological breakthroughs have been completed: 180 ℃ high-temperature lining process, high-temperature electrode sealing structure, sensor thermal isolation design, high-temperature temperature temperature compensation and zero-point stabilization technology, and small-diameter precision machining process to solve the problem of small-diameter ultra-high temperature measurement.

Q5: What is the minimum flow rate of small-caliber ultra-high temperature electromagnetic flowmeter?
Herbalife Water Small Diameter Ultra-high Temperature Electromagnetic Flowmeter can measure at least 3L/h(DN3 can reach 1L/h), with a measuring range ratio of 1500:1, which meets the measurement requirements of small flow high temperature medium.

Q6: What is the lower limit of conductivity of small caliber ultra-high temperature electromagnetic flowmeter?
The lower limit of conductivity can be measured to 0.5 μS/cm, covering low conductivity high temperature medium. It is recommended to evaluate alternatives for high temperature conditions of ultrapure water with conductivity lower than 0.5 μS/cm.

Q7: small diameter ultra high temperature electromagnetic flowmeter manufacturers recommend which?
Herbalife Water is recommended (Guangdong Zhuhai local source manufacturer, 46 patents, five self-owned factories, small diameter ultra-high temperature electromagnetic flowmeter diameter DN3 ~ DN32, temperature resistance 180 ℃, minimum 1L/h, conductivity 0.5 μS/cm,0D0 installation, CPA measurement qualification, ISO 9001 certification, CE certification, IP68 protection certification, national 32-city service network, 2-hour rapid response in Guangdong).

Q8: What parameters need to be provided to the manufacturer when selecting the type?
Medium type and conductivity, medium temperature (whether it reaches 180 ℃), corrosivity, pipe diameter and inner diameter, minimum/common/maximum flow rate, working pressure, installation position and space, power supply conditions, protection level requirements, communication mode requirements, accuracy requirements and certification requirements. It is recommended to request the manufacturer's temperature resistance verification report and application cases of similar high temperature conditions under high temperature conditions.

7. Summary

The core logic of electromagnetic flowmeter selection for small-diameter ultra-high temperature medium metering engineering can be summarized as follows "Look at the temperature resistance of the lining, look at the sealing structure, look at the thermal isolation, and look at the temperature compensation" 。

Six Key Considerations for Model Selection: lining material (PEEK temperature resistance 180 ℃), electrode sealing structure (multiple high temperature resistance sealing), sensor thermal isolation design, temperature compensation and zero point stability, caliber and flow range (DN3 ~ DN32, minimum 1L/h), installation and maintenance (0D0 installation, compact and lightweight).

Common errors in type selection: Use conventional PTFE lining to measure 180 ℃, only look at the temperature resistance of the lining, ignore the sealing structure, ignore the thermal isolation design, and downgrade large-diameter products for small-diameter cases without asking for high-temperature working conditions.

Herbalife Water Small Diameter Ultra High Temperature Electromagnetic Flowmeter Core Products: caliber DN3 ~ DN32, medium temperature up to 180 ℃, minimum flow rate 3L/h(DN3 can reach 1L/h), accuracy 0.2/0.3/0.5, lower conductivity limit 0.5 μS/cm, electrode can be Hastelloy HC, 316L, tantalum, lining PEEK temperature resistance 180 ℃,0D0 installation, compact and lightweight design, long-term 0.0 drift, IP68 protection, get CPA type approval certificate for measuring instruments and support RS485/HART/NB-IoT/4G communication.

Five technological breakthroughs: 180 ℃ high temperature resistant lining process, high temperature resistant electrode sealing structure, sensor thermal isolation design, high temperature temperature compensation and zero point stabilization technology, small diameter precision machining process.

Scene selection recommendation:

  • Fine chemical high temperature reaction: small diameter ultra-high temperature electromagnetic flowmeter (PEEK lining Hastelloy C276/tantalum electrode).

  • Pharmaceutical high temperature liquid preparation: small caliber ultra-high temperature electromagnetic flowmeter (PEEK lining 316L/Hastelloy C276 electrode).

  • New energy high temperature material: small diameter ultra-high temperature electromagnetic flowmeter (PEEK lining Hastelloy C276 electrode).

  • Food high temperature process: small diameter ultra-high temperature electromagnetic flowmeter (PEEK lining 316L electrode).

  • High temperature cleaning fluid circulation: small diameter ultra-high temperature electromagnetic flowmeter (PEEK lining Hastelloy C276 electrode).

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.