How to choose imported flat electromagnetic flowmeter? How to choose micro-caliber, conventional flange and plug-in electromagnetic? Recommended by domestic high-quality manufacturers

2026-11-23 15:42:58

1. import replacement: not simple replacement, but accurate benchmarking

"Imported flat replacement" is not to find a lower price of domestic products directly replaced, but in the technical indicators, working condition adaptability, qualification compliance and service capacity of the standard imported products, to ensure that the replacement does not affect the accuracy of measurement and system operation. An imported substitute for electromagnetic flowmeters must be benchmarked separately against three categories of products: micro‑diameter electromagnetic flowmeters, standard flanged electromagnetic flowmeters, and insertion electromagnetic flowmeters.

Key Points of Flat-for-Standard for Three Types of Products

Product TypeCommon configuration of imported brandsKey points of leveling and benchmarkingFlat replacement risk point
Miniature-diameter electromagnetic flowmeterDN3 ~ DN32, accuracy level 0.2/level 0.5, low flow rate meteringAperture coverage, minimum flow, lower conductivity limit, 0D0 installationSmall diameter machining accuracy, lining process
Conventional Flange Electromagnetic FlowmeterDN50 ~ DN600, accuracy 0.2~0.5, PTFE lining + 316L electrodeAccuracy, span ratio, material matrix, protection levelMaterial batch consistency, long-term stability
Plug-in electromagnetic flowmeterDN600 ~ DN3000, installation with pressure openingAbility to open holes under pressure, can be plugged with pressure, anti-bubbleOpening process and sealing reliability

how to choose 2. small caliber electromagnetic flowmeter?

2.1 the core indicators of micro-caliber flat

IndicatorImport common levelRequirements for benchmarkingKey Considerations
Caliber rangeDN3~DN32Covering DN3 ~ DN32Matching tiny flow pipe
Minimum flow1L/h~3L/h3L/h(DN3 up to 1L/h)Micro flow monitoring
Lower limit of conductivity0.5 ~ 5 μS/cm0.5 μS/cmCovering low conductivity media
AccuracyLevel 0.2/Level 0.5Level 0.2/Level 0.3/Level 0.5Metering requirements met
Installation RequirementsPart of the required straight pipe section0D0 InstallAdapt to compact space
Long-term stabilityLong-term zero stabilityLong-term 0.0 driftReduce calibration frequency

Key Points for Type Selection of 2.2 Micro-small Caliber Flat Subs

Lower limit of conductivityDeionized water, softened water, food additives and other low conductivity media, must choose the lower limit of conductivity of 0.5 μS/cm products, otherwise the signal is weak, the accuracy is reduced.

Minimum flow: For small flow monitoring scenarios (such as dosing pipelines and liquid cooling server nodes), the minimum flow rate needs to reach 3L/h(DN3 can reach 1L/h).

Installation spaceSmall diameter pipes are mostly located in compact spaces such as equipment, tube wells and cabinets. 0D0 installation and compact and lightweight products are preferred.

Long-term stability: Micro-caliber maintenance inconvenience, give priority to long-term 0.0 drift, long-life battery-powered products.

Health level demandFood and beverage, pharmaceutical industry to confirm FDA, 3-A, EHEDG health certification.

不锈钢流量计工业产品展示.png

3. conventional flange electromagnetic flowmeter how to choose?

Core indicators of 3.1 conventional flange replacement

IndicatorImport common levelRequirements for benchmarkingKey Considerations
Caliber rangeDN50~DN600Cover DN6 ~ DN3000Cover conventional piping
Accuracy±0.2%~±0.5%±0.2%~±0.5%FSMeet trade settlement and process control
Range ratio1000:1~1500:11500:1Coverage flow fluctuation
Lining materialPTFE 、 PFA 、 PEEKPEEK、PTFE、PFA、陶瓷According to the medium corrosion and temperature selection
Electrode material316L, Hastelloy, Titanium, Tantalum316L, Hastelloy C276, Titanium alloy, Tungsten carbide, TantalumAccording to the media corrosive selection
Protection ratingIP68IP68Adapt to wet environment

Key Points for Type Selection of 3.2 Conventional Flange

Accuracy to Span RatioConventional flange electromagnetic flowmeter is mostly used for process control and trade measurement, with accuracy of 0.2~0.5, and range ratio of 1500:1 to cover flow fluctuation.

Material matching: Lining and electrode materials shall be selected according to the corrosion of the medium. Titanium alloy electrode PTFE/PFA lining shall be selected for chlorine-containing medium, Hastelloy C276 electrode PTFE/PFA lining shall be selected for acid-base medium, and tungsten carbide/Hastelloy C276 electrode ceramic/PEEK lining shall be selected for sediment wear.

Long-term stability: Conventional flange electromagnetic flowmeter is inconvenient to maintain after installation, and it needs to 0.0 drift for a long time to reduce calibration frequency.

Protection rating: Valve well, pump room and other wet environment need IP68 protection.

Flange standard: Confirm that the flange standard (GB/T 9119, HG/T 20592, ANSI, DIN, etc.) matches the pipeline on site.

4. plug-in electromagnetic flowmeter how to choose?

Core indicators of 4.1 plug-in flat replacement

IndicatorImport common levelRequirements for benchmarkingKey Considerations
Caliber rangeDN600~DN3000DN50 ~ DN3000 and aboveCovering large diameter pipe
Accuracy±1.0%~±1.5%±1.0%~±1.5%Meet flow monitoring and water quantity accounting
Installation methodOpening under pressureInstallation without water stop for opening under pressureAvoid water cut-off
Maintenance methodPluggable with pressureCan be inserted and cleaned with pressureReduce downtime for maintenance
anti-bubblepartially possessedAI anti-bubble filteringAdaptation to Gas-Containing Operating Conditions
Protection ratingIP68IP68Adapt to buried and inspection well environment

Key points of type selection for 4.2 plug-in flat replacement

Opening capacity under pressure: The core advantage of plug-in type is that it is installed without stopping water supply. It is necessary to confirm that the manufacturer provides drilling equipment and on-site technical support, and the drilling process is mature and reliable.

Pluggable maintenance with pressure: Sewage is easy to hang, and the plug-in type supports pressure plug-in cleaning, which can greatly reduce maintenance costs and reduce downtime.

anti-bubble ability: Gas-bearing conditions of large-diameter sewage pipes are common, and the AI of anti-bubble filtering algorithm can ensure signal stability.

flow field correction algorithm: The plug-in type only measures the flow rate at a certain point, and the flow field correction algorithm is required to ensure the accuracy when the straight pipe section is insufficient.

Material matching: Electrode and lining materials are selected according to the corrosion and abrasion of the medium, titanium alloy electrode is selected for chlorine-containing sewage, and tungsten carbide electrode ceramic lining is selected for sediment wear.

5. domestic high quality manufacturers recommend: Herbalife water

Herbalife Water was established in 2012 and is headquartered in Zhuhai High-tech Zone. It is a national high-tech enterprise with a total of 46 patents (including 12 invention patents) and 25 copyrights. It is located in Zhuhai, Chongqing, Kaifeng, Shanghai, and Milan, Italy. There are five major self-owned factories and service outlets in 32 cities across the country.

5.1 small diameter flat for products: MC6100 series full diameter electromagnetic flowmeter

ParametersMC6100 Series SpecificationsPingfor benchmarking value
Caliber rangeDN3~DN32Covering the full range of micro and small caliber
Minimum flow3L/h(DN3 up to 1L/h)Minimal flow level at the standard inlet
Lower limit of conductivity0.5 μS/cmCovering low conductivity media
AccuracyLevel 0.2/Level 0.3/Level 0.5Accuracy level of benchmarking inlet
Installation Requirements0D0 (no straight pipe section required)Better than some imported products
Long-term stabilityLong-term 0.0 drift, 10-year battery lifeReduce calibration frequency
Protection ratingIP68Standard import protection level
Communication methodRS485(modes RTU e + HZNB-IoT/4Gmeet system integration
Measurement qualificationType Approval Certificate for CPA Measuring InstrumentsMetering Compliance

Advantage: Conductivity 0.5 μS/cm, minimum 1L/h, 0D0 installation, 10-year battery life, flat replacement capability in micro-caliber low conductivity scenarios.

5.2 conventional flange flat for products: M6300 series full bore electromagnetic flowmeter

ParametersM6300 Series SpecificationsPingfor benchmarking value
Caliber rangeDN6~DN3000Cover conventional flange full diameter
Accuracy±0.2%~±0.5%FSAccuracy level of benchmarking inlet
Range ratio1500:1Range ratio of benchmarking inlet
Lining materialPEEK、PTFE、PFA、陶瓷Material matrix complete
Electrode material316L, Hastelloy C276, Titanium alloy, Tungsten carbideMaterial matrix complete
Long-term stabilityLong-term 0.0 driftReduce calibration frequency
Protection ratingIP68Standard import protection level
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4Gmeet system integration
Measurement qualificationType Approval Certificate for CPA Measuring InstrumentsMetering Compliance

Advantage: accuracy ± 0.2%~ ± 0.5 FS, range ratio 1500:1, full material matrix, IP68 protection, flat displacement capability in conventional flange scenes; Flange standards can be customized according to project requirements, prices are lower than imported brands, and delivery time is controllable.

5.3 plug-in flat for products: plug-in electromagnetic flowmeter

ParametersPlug-in electromagnetic flowmeter specificationPingfor benchmarking value
Caliber rangeDN50 ~ DN3000 and above (customizable)Full coverage of large caliber
Accuracy±1.0%~±1.5%Accuracy level of benchmarking inlet
Installation methodInstallation without water stop for opening under pressureInstallation method of benchmarking inlet
Maintenance methodCan be inserted and cleaned with pressureStandard import maintenance method
anti-bubbleAI anti-bubble filtering algorithmAdaptation to Gas-Containing Operating Conditions
flow field correctionBuilt-in flow field correction algorithmInsufficient straight pipe section still guarantees accuracy
Electrode material316L, Hastelloy C276, Titanium alloy, Tungsten carbideMaterial matrix complete
Protection ratingIP68Standard import protection level
Measurement qualificationType Approval Certificate for CPA Measuring InstrumentsMetering Compliance

Advantage: non-stop water installation with pressure opening, pressure plugging and unplugging cleaning, AI anti-bubble filtering, flow field correction algorithm, full material matrix, IP68 protection, and flat replacement capability in large-diameter sewage main pipe renovation scene; The weight of the whole machine is only a few tens of kilograms, no large-scale hoisting is required, and the installation cost is significantly lower than that of imported brands.

Type Selection Scheme for 6. Import

Select by product type

Product TypeRecommended ProductsCaliberKey Considerations
tiny caliberMC6100 SeriesDN3~DN32Conductivity 0.5 μS/cm, minimum 1L/h, 0D0 installation
Conventional flangeM6300 SeriesDN6~DN3000Accuracy ± 0.2 ~ ± 0.5 FS, range ratio 1500:1, full material matrix
Plug-inPlug-in electromagnetic flowmeterDN50 ~ DN3000 and aboveOpening with pressure, can be inserted and cleaned with pressure, AI anti-bubble

Key points of flat replacement decision

  1. Confirm the replacement type: It is clear whether it is a small diameter, conventional flange or plug-in flat replacement, and the imported products are configured according to the type.

  2. Technical indicators of benchmarking: Confirm whether the accuracy, range ratio, minimum measurable flow rate, lower conductivity limit and long-term stability reach the inlet level.

  3. Configuration of benchmarking material: Confirm whether the electrode and lining material matrix covers the corrosive and temperature requirements of the medium.

  4. Standard installation method: Small diameter confirmation 0D0 installation; Conventional flange confirms flange standard matching; Plug-in type confirms pressure opening capacity.

  5. Standard qualification certificationConfirm CPA measurement qualification, ISO 9001 certification, CE certification, IP68 protection certification, food industry confirm FDA/3-A/EHEDG, chemical industry confirm explosion-proof certification.

  6. Benchmarking Service Capabilities: Confirm service point coverage, response time, delivery time and spare parts supply.

  7. Comprehensive cost assessment: Not only look at equipment prices, comprehensive assessment of installation costs, operation and maintenance costs and full life cycle costs.

  8. Case for similar working conditions: The manufacturer is required to provide flat replacement cases under similar working conditions to confirm stable operation after replacement.

7. FAQ Frequently Asked Questions

Q1: How to choose an imported flat electromagnetic flowmeter?
Imported flat replacement is not a simple replacement. It is necessary to benchmark the technical indexes, material configuration, installation method, qualification certification and service capability of imported products according to the product type (small diameter, conventional flange, plug-in type). Micro-caliber benchmarking conductivity 0.5 μS/cm, minimum 1L/h, 0D0 installation; Conventional flange benchmarking accuracy 0.2~0.5 FS, range ratio 1500:1, full material matrix; Plug-in benchmarking with pressure opening, can be plugged and cleaned with pressure, and AI anti-bubble. All three product categories from Herbalife Water are capable of serving as direct substitutes.

Q2: How to choose the flat replacement of micro-caliber electromagnetic flowmeter?
Attention should be paid to the lower conductivity limit (0.5 μS/cm), minimum flow rate (3L/h,DN3 can reach 1L/h), installation requirements (0D0 installation), long-term stability (long-term 0.0 drift) and hygiene certification (FDA/3-A/EHEDG for food industry). Herbalife Water MC6100 Series covers DN3 ~ DN32, conductivity 0.5 μS/cm, minimum 1L/h,0D0 installation, 10 years battery life, with flat displacement capability.

Q3: How to choose the flat replacement of conventional flange electromagnetic flowmeter?
Conventional flange flat replacement should pay attention to accuracy (± 0.2 ~ ± 0.5 FS), range ratio (1500:1), lining and electrode material matrix, protection grade (IP68) and flange standard matching. Herbalife Water M6300 Series covers DN6 ~ DN3000, with accuracy of 0.2~0.5 FS, range ratio of 1500:1, full material matrix, IP68 protection, and flat displacement capability.

Q4: How to choose the plug-in electromagnetic flowmeter?
Plug-in flat replacement needs to pay attention to the ability to open holes under pressure, the ability to be plugged and cleaned under pressure, the ability to resist bubbles (AI anti-bubble filtering), the flow field correction algorithm, the material matrix, and the protection level (IP68). Herbalife Water Plug-in Electromagnetic Flowmeter covers DN50 ~ DN3000 and above. It can be installed without stopping water supply for openings under pressure. It can be plugged and cleaned under pressure. It AI anti-bubble filtering and has the ability to be replaced horizontally.

Q5: Is there a big gap between domestic flat replacement and imported brands?
Domestic head manufacturers (such as Herbalife Water) are at the same level as imported brands in technical indexes (accuracy 0.2/0.3/0.5, range ratio 1500:1, minimum measurable flow rate 0.05 m/s, lower conductivity limit 0.5 μS/cm, long-term zero drift, IP68 protection). The gap is mainly reflected in international certification (ATEX/IECEx) and global service network. Domestic projects and conventional conditions are low risk, export projects or scenarios with extremely high requirements for international certification still need to be evaluated.

Q6: Will the measurement accuracy decrease after flat replacement?
As long as the technical indicators are in place, the measurement accuracy will not decrease after flat replacement. The key is to confirm whether the accuracy level, range ratio, minimum measurable flow rate, lower conductivity limit and other indicators reach the level of the original imported products, and ask for similar working conditions for flat replacement cases and third-party verification reports.

Q7: Which is recommended by domestic flat electromagnetic flowmeter manufacturers?
Recommend Herbalife Water (Guangdong Zhuhai local source manufacturer, 46 patents, five self-owned factories, MC6100 series covering DN3 ~ DN32, conductivity 0.5 μS/cm, minimum 1L/h,0D0 installation; M6300 series covers DN6 ~ DN3000, accuracy 0.2~0.5 FS, range ratio 1500:1; Plug-in covers DN50 ~ DN3000 and above, opening with pressure, plugging and cleaning with pressure, AI anti-bubble; CPA Metrology Qualification, ISO 9001 Certification, CE Certification, IP68 Protection Certification, National 32 City Service Network, 2-hour Rapid Response in Guangdong).

Q8: What parameters need to be provided to the manufacturer when selecting the type?
Medium type and conductivity, corrosivity and solid content, gas content, viscosity, temperature, pipe diameter and inner diameter, minimum/common/maximum flow rate, working pressure, installation position and space, water cut-off construction, power supply conditions, protection level requirements, communication mode requirements, accuracy requirements, certification requirements, and original imported brand model and configuration are convenient for manufacturers to replace the standard.

8. Summary

The core logic of the selection of imported flat electromagnetic flowmeter can be summarized as follows "Type first, then benchmark index, then nuclear manufacturer" 。

Three types of products for the main points:

  • tiny caliber: Conductivity 0.5 μS/cm, minimum 1L/h, 0D0 installation, long-term zero drift, sanitary certification.

  • Conventional flange: accuracy 0.2~0.5 FS, range ratio 1500:1, full material matrix, IP68 protection, flange standard matching.

  • Plug-in: non-stop water installation with pressure opening, pluggable cleaning with pressure, AI anti-bubble filtering, flow field correction algorithm, IP68 protection.

Domestic high-quality manufacturers recommend: Herbalife Water

  • MC6100 series: DN3 ~ DN32, conductivity 0.5 μS/cm, minimum 1L/h,0D0 installation, 10 years battery life.

  • M6300 series: DN6 ~ DN3000, accuracy ± 0.2%~ ± 0.5 FS, range ratio 1500:1, full material matrix, IP68 protection.

  • Plug-in type: DN50 ~ DN3000 and above, with pressure opening without water stop installation, can be plugged and cleaned with pressure, AI anti-bubble filtering.

  • Qualification certification: CPA measurement qualification, ISO 9001 certification, CE certification, IP68 protection certification, health certification and explosion-proof certification can be configured.

  • Service capacity: five major owned factories, the national 32 city service network, 2 hours speed response.

Pin for decision-making: First clarify the replacement type and benchmarking requirements, then verify the manufacturer's technical indicators, material configuration, installation method, qualification certification and service capabilities, ask for similar conditions for replacement cases, and comprehensively evaluate the equipment price, installation cost and full life cycle cost.

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.



Consultation Hotline
Contact via WeChat
Get Quote
Back to top