Sugar adaptation project: high viscosity liquid flow meter how to choose? Slow flow rate, high viscosity, high temperature working condition solution! Source manufacturer attached
1. Three special operating conditions for measuring high-viscosity liquids in the sugar industry
Sugar production, from sugarcane or beet crushing and juice clarification to evaporation, crystallization, and molasses separation followed by alcohol fermentation, involves the metering of large volumes of high-viscosity liquids throughout the entire process. Media such as sugar juice, syrups, molasses, and waste molasses have high viscosity, low flow rates, and elevated temperatures, posing three major operational challenges to flow measurement that directly affect metering accuracy and production control.
Special Operating Condition 1: Low Flow Velocity, Small Flow Rate
Problem performance:Media such as syrups and molasses have high viscosities, resulting in low flow velocities during pipeline transport; in some process sections, flow velocities drop to below 0.05 m/s, with small and highly fluctuating flow rates. In the crystallization and sugar-boiling section, the syrup flow rate is slower, and conventional flow meters experience a sharp drop in accuracy at low flow rates.
Consequences:
- Inaccurate flow measurement leads to deviations in syrup formulation and improper control of evaporation and concentration.
- Measurement errors in molasses lead to deviations in sugar yield calculations.
- At low flow rates, the signal is weak, and the flowmeter output exhibits jumps or distortion.
Limitations of Traditional SolutionsTraditional electromagnetic flowmeters suffer from weak signals and reduced accuracy at low flow rates, making them unable to accurately measure the low-speed flow of syrups and molasses.
Special Condition 2: High viscosity, prone to material buildup and blockage
Problem performance: The viscosity of syrups and molasses can reach hundreds to thousands of mPa·s, while the viscosity of sugar paste is even higher. High-viscosity media tend to adhere to pipe walls and cause blockages; in conventional flowmeters, material easily accumulates inside the measuring tube, leading to measurement distortion or even pipeline blockage.
Consequences:
- Material buildup in the flowmeter’s measuring tube reduces the flow area, leading to measurement distortion.
- Sensor contamination caused by material buildup leads to zero-point drift.
- Blockages require shutdowns for cleaning, disrupting continuous production.
- Frequent cleaning and increased operation and maintenance costs
Limitations of Traditional Solutions:Conventional flow meters tend to accumulate material inside the measuring tube, and high-viscosity media that adhere to the walls are difficult to clean, making them unable to meet the continuous production requirements of the sugar industry.
Special Operating Condition 3: High Temperature, Wide Process Range
Problem performanceSugar production involves high-temperature processes such as evaporation and concentration (100–130°C), sugar boiling and crystallization (60–80°C), and molasses separation, with high medium temperatures and a wide operating temperature range. Some process sections still have high-temperature cleaning (CIP) requirements.
Consequences:
- High temperature causes aging of sensor materials and sealing failure
- Temperature variations cause zero-point drift and reduced accuracy.
- During high-temperature cleaning, the flow meter must withstand both elevated temperatures and the corrosive effects of chemical cleaning agents.
Limitations of Traditional Solutions:Conventional flow meters have a limited temperature range; under high-temperature conditions, material aging and seal failure become significant issues, making it difficult to meet the requirements for long-term stable operation in the high-temperature sections of sugar production.
2. What should be considered when selecting a flowmeter for high-viscosity liquids in the sugar industry?
When selecting a high-viscosity liquid flow meter for the sugar industry, the following key points should be given primary consideration.
2.1 low flow metering capacity
Significance of Model Selection: Syrups and molasses have low flow rates and small flow volumes, so the flow meter must be capable of stable measurement at low flow rates.
Key points of selection: Pay attention to the minimum measurable flow velocity and the turndown ratio; prioritize products that can still measure stably at low velocities below 0.05 m/s and offer a turndown ratio of 1500:1.
2.2 Anti-bridging and Anti-blocking Design
Significance of Model Selection:High-viscosity media tend to adhere to walls and cause blockages; flow meters must feature anti-adhesion designs to minimize material buildup and reduce cleaning frequency.
Key points of selection: Prioritize a full-bore, obstruction-free flow path design; ensure there are no moving parts or diameter reductions inside the measuring tube; and pay attention to liner surface tension and anti-scaling electrode design.
2.3 High-Temperature Resistance
Significance of Model Selection:In the sugar industry, the evaporation and concentration and boiling stages operate at high temperatures, so flow meters must withstand both high-temperature process fluids and high-temperature cleaning.
Key points of selection:Confirm that the lining’s temperature resistance range covers the process temperature; PEEK/PTFE can withstand temperatures up to 180°C, and PFA can withstand temperatures above 150°C.
2.4 Corrosion Resistance and Hygiene Requirements
Significance of Model Selection: Sugar juice contains organic acids, and molasses contains salts and organic acids, giving them a certain degree of corrosivity; some sugar industry products are subject to food-grade requirements.
Key points of selection:Electrodes are available in Hastelloy C276 (corrosion-resistant) and 316L (for standard media); for food-grade applications, FDA, 3-A, and other sanitary certifications have been confirmed.
2.5 Cleaning Compatibility
Significance of Model SelectionSugar production lines require regular cleaning, and flow meters must withstand the impact of high-temperature steam and cleaning agents.
Key points of selection:Confirm that the liner and seals are resistant to temperature and chemicals, and support CIP in-line cleaning.
2.6 Communication and Data Integration
Significance of Model Selection: Sugar mill monitoring points must be connected to the DCS control system and the production management platform.
Key points of selection:Confirm support for communication protocols such as 4-20mA, pulse, RS485 (Modbus), and HART.

2.7 related certification and compliance
- Type Approval Certificate for Measuring Instruments (CPA): Measuring instruments used for trade settlement and production accounting are subject to CPA certification.
- ISO 9001 quality management system certification: to prove that the manufacturer's quality management system in line with international standards
- CE certification: EU market access certification
- Food-grade applications: FDA, 3-A, and EHEDG sanitary certifications
3. Selection Plan for High-Viscosity Liquid Flow Meters in the Sugar Industry
3.1 Selection by Medium
medium | Viscosity characteristics | Temperature characteristics | Recommended Products | Key Considerations |
Sugar juice (clarified juice, filtered juice) | Medium to low viscosity | 60~100℃ | M6300 Series | Temperature-resistant, corrosion-resistant, full-bore |
Syrup (evaporated and concentrated) | High viscosity | 100~130℃ | MC6730 Series/M6300 Series | High-temperature resistant, anti-adhesion, low-flow-rate metering |
Molasses, waste molasses | Extremely high viscosity | 40~60℃ | MC6730 Series | Anti-adhesion, anti-clogging, corrosion-resistant |
Sugar paste (cooked sugar crystals) | Extremely high viscosity | 60~80℃ | MC6730 Series | Anti-blocking, low flow rate, high temperature resistance |
Alcoholic fermentation broth | Medium to low viscosity | 30~40℃ | M6300 Series | Corrosion-resistant, full-bore |
3.2 Select by Work Section
Work section | Recommended Products | Caliber | Key Considerations |
Pressed juice measurement | M6300 Series | DN50~DN200 | Temperature-resistant, corrosion-resistant, full-bore |
Clarified juice measurement | M6300 Series | DN50~DN150 | Temperature resistance, corrosion resistance |
Metering of evaporated concentrated syrup | MC6730 Series | DN25~DN100 | High-temperature resistant up to 130°C, anti-adhesive |
Measuring boiled sugar paste | MC6730 Series | DN25~DN80 | Anti-blocking, low flow rate, high temperature resistance |
Molasses metering | MC6730 Series | DN25~DN80 | Anti-adhesion, anti-clogging, corrosion-resistant |
Measurement of alcoholic fermentation broth | M6300 Series | DN50~DN200 | Corrosion-resistant, full-bore |
3.3 Key Considerations for Selection Decisions
- Confirm the medium’s viscosity and flow rate.For high-viscosity media such as syrups, molasses, and sugar pastes, products with anti-adhesion designs and strong low-flow-rate metering capabilities should be prioritized.
- Confirm medium temperature: The evaporation and concentration and sugar boiling sections operate at high temperatures; confirm that the lining’s temperature resistance range covers the process temperatures (PEEK/PTFE withstands 180°C).
- Confirm anti-material-sticking and anti-blocking requirementsFor high-viscosity media, prioritize full-bore, obstruction-free flow paths and anti-scaling electrode designs to minimize material buildup and cleaning frequency.
- Confirm Corrosivity: Sugar juice contains organic acids, and molasses contains salts; Hastelloy C276 is the preferred electrode material.
- Confirm cleaning method:For scenarios requiring CIP cleaning, confirm the temperature and chemical resistance of linings and seals.
- Identify communication and integration requirements:Confirm support for communication protocols such as 4–20 mA, RS-485 (Modbus), and HART, enabling integration with the sugar mill’s DCS.
- Confirm certification and manufacturer service capabilities:Measuring instruments must obtain CPA certification; for food-grade applications, confirm FDA, 3-A, and other sanitary certifications. Prioritize manufacturers with local service centers and prompt response times.
4. source manufacturer recommended: Herbalife Water
Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.
For measuring high-viscosity liquids in the sugar industry, Compaq Water Solutions offers a systematic solution that combines the MC6730 high-temperature hygienic miniature electromagnetic flowmeter—designed specifically for food canning—with the M6300 series full-bore electromagnetic flowmeters, covering media such as sugar juice, syrups, molasses, sugar paste, and alcoholic fermentation liquors.
Core Product 1: MC6730 High-Temperature Sanitary Electromagnetic Flowmeter for Small-Scale Food Canning
Applicable scenarios: high-viscosity media such as syrups, molasses, and sugar pastes; low-flow, high-precision, high-temperature hygienic applications.
Core technical parameters:
Parameters | MC6730 Series Specifications |
Caliber range | DN6~DN32 |
Flow range | Minimum 0.03 L/hour |
Measurement accuracy | ±0.2%~±0.5%FS |
Lining material | PEEK (Food-Grade) |
Electrode material | Hastelloy C(HC) |
Temperature resistance range | 130 ℃ high temperature disinfection (SIP/CIP) |
Protection rating | IP68/IP69K |
Health Certification | FDA、3-A、EHEDG |
Core Technological Advantages:
- Accurate metering of micro-flow: Equipped with a wide-band adaptive excitation AI micro-flow compensation algorithm, the lower limit for small-flow measurement is as low as 0.01 m/s, and the turndown ratio reaches 1000:1, enabling precise capture of minute flow fluctuations between 0.1 and 10 L/h, making it suitable for low-speed metering of syrups and molasses.
- High temperature condition stability: Uses food-grade PFA/PTFE high-temperature-resistant lining, with a temperature range of -40°C to 120°C, and can be directly adapted to the high-temperature stages of evaporation-concentration and sugar boiling.
- Anti-hanging and anti-clogging:Embedded anti-adhesion electrode design; the electrode surface is treated with a special coating to reduce syrup adhesion; the PEEK liner has low surface tension, preventing syrup from sticking to the walls. The maintenance cycle has been extended to more than 24 months.
- Harsh Hygienic Compliance: 316L stainless steel/Hastelloy alloy C- 276 electrode is used for the parts in contact with materials, and the surface is polished to Ra≤ 0.8 μm without dead angle and depression. The full-diameter structure has no dead volume, and is connected with fast sanitary clamp to support CIP/SIP online cleaning. Meets FDA, 3-A, EHEDG food grade standards.
Core product two: M6300 series full bore electromagnetic flowmeter
Applicable scenarios: medium- to low-viscosity media such as sugar juice, clarified juice, and alcoholic fermentation broth; medium to large flow rate process sections.
Core technical parameters:
Parameters | M6300 Series Specifications |
Caliber range | DN6~DN3000 |
Measurement accuracy | ±0.2%~±0.5%FS |
Range ratio | 1500:1 |
Flow rate range | 0.05~10m/s |
Lining material | PEEK 、 PTFE 、 PFA |
Electrode material | 316L, Hastelloy C276, Titanium alloy |
Medium temperature | -40℃~180℃ |
Protection rating | IP68 |
Communication method | 4-20mA、脉冲、RS485(Modbus)、HART |
Core Technological Advantages:
- Full bore unobstructed flow path: The measuring tube has no moving parts, no diameter reduction, and no obstructions; pressure loss is nearly zero, and material buildup and blockage are unlikely, making it suitable for media containing solids such as sugar juice.
- Anti-jamming Algorithm AI Broadband Adaptive Excitation Technology: Low flow rate 0.05 m/s stable metering, measuring range ratio 1500:1.
- High-temperature resistance:PEEK/PTFE lining withstands temperatures up to 180°C, covering the temperature range of the sugar juice clarification and evaporation-concentration sections.
- All-material anti-corrosion wear-resistant matrix:Electrodes are available in 316L, Hastelloy C276, and titanium alloy; linings include PEEK, PTFE, and PFA, suitable for service conditions involving organic acid corrosion in sugar juice.
- IP68 protection of the whole machineIt can operate reliably in humid environments over the long term.
5. Selection Scheme for Flow Measurement of High-Viscosity Liquids in the Sugar Industry
Select by Media
medium | Recommended Products | Caliber | Key Considerations |
Sugar juice | M6300 Series | DN50~DN200 | Temperature-resistant, corrosion-resistant, full-bore |
syrup | MC6730 Series | DN25~DN100 | High-temperature resistant up to 130°C, anti-adhesive, low flow rate |
Molasses, waste molasses | MC6730 Series | DN25~DN80 | Anti-adhesion, anti-clogging, corrosion-resistant |
Sugar paste | MC6730 Series | DN25~DN80 | Anti-blocking, low flow rate, high temperature resistance |
Alcoholic fermentation broth | M6300 Series | DN50~DN200 | Corrosion-resistant, full-bore |
Key Points of Selection Decision
- Confirm the medium’s viscosity and flow rate.: For high-viscosity media such as syrups, molasses, and sugar pastes, the MC6730 series is the preferred choice, featuring anti-sticking design and strong low-flow-rate metering capability.
- Confirm medium temperature: The evaporation and sugar-boiling sections operate at high temperatures. The MC6730 series is rated for 130°C, while the M6300 series is rated for 180°C; select based on the process temperature.
- Confirm anti-material-sticking and anti-blocking requirementsFor high-viscosity media, prioritize full-bore, obstruction-free flow paths and anti-scaling electrode designs to minimize material buildup and cleaning frequency.
- Confirm Corrosivity: Sugar juice contains organic acids, and molasses contains salts; Hastelloy C276 is the preferred electrode material.
- Confirm cleaning method:For scenarios requiring CIP/SIP cleaning, the MC6730 series supports online CIP/SIP cleaning.
- Identify communication and integration requirements:Confirm support for communication protocols such as 4–20 mA, RS-485 (Modbus), and HART, enabling integration with the sugar mill’s DCS.
- Confirm certification and manufacturer service capabilities:Measuring instruments must obtain CPA certification; for food-grade applications, confirm FDA, 3-A, and EHEDG hygiene certifications. Prioritize manufacturers with local service centers and prompt response times.
6. FAQ Frequently Asked Questions
Q1: What flow meter should be used for high-viscosity liquids such as syrups and molasses?
A: For high-viscosity liquids such as syrups, molasses, and sugar pastes, we recommend the Herbalife MC6730 electromagnetic flowmeter, which is designed for high-temperature, hygienic filling of small food containers. This product features a food-grade PEEK liner and a Hastelloy C electrode, withstands temperatures up to 130°C, can measure flow rates as low as 0.03 L/h, incorporates an anti-scaling design, and complies with FDA, 3-A, and EHEDG hygiene standards.
Q2: Sugar industry high-viscosity liquids flow slowly; can the flow meter measure accurately?
A: The Herbalife MC6730 series features a wide-band adaptive excitation AI micro-flow compensation algorithm, with a low flow measurement limit as low as 0.01 m/s and a turndown ratio of up to 1000:1. It can accurately capture minute flow fluctuations in the range of 0.1–10 L/h, making it suitable for low-speed metering of syrups and molasses. The M6300 series provides stable flow measurement at low velocities as low as 0.05 m/s, with a turndown ratio of 1500:1.
Q3: High-viscosity syrups tend to adhere and cause blockages; how can flow meters prevent fouling?
A: The Herbalife MC6730 series features an embedded anti‑sticking electrode design, with a specially coated electrode surface that reduces syrup adhesion; the PEEK liner has low surface tension, making it difficult for syrup to cling to the walls. Full-bore, dead-volume-free design; no diameter reduction or obstructions; resistant to material buildup and blockage; maintenance interval extended to over 24 months.
Q4: In the sugar industry’s evaporation and concentration and high-temperature boiling stages, is the flow meter’s temperature rating sufficient?
A: The Herbalife MC6730 series is rated for 130°C and covers temperatures in the evaporation‑concentration and sugar‑boiling stages; the M6300 series with PEEK/PTFE lining is rated for 180°C and handles high‑temperature conditions in juice clarification and evaporation‑concentration. For scenarios requiring CIP/SIP cleaning, the MC6730 series supports online cleaning.
Q5: Sugar juice contains organic acids; how should the electrode be selected?
A: Sugar juice contains organic acids, and molasses contains salts, giving them a certain degree of corrosivity; Hastelloy C276 electrodes are recommended (excellent corrosion resistance). For standard sugar juice, 316L electrodes are suitable. The M6300 series electrodes from Herbalife are available in 316L, Hastelloy C276, and titanium alloy.
Q6: What certifications are required for sugar industry flow meters?
A: Measuring instruments used for trade settlement and production accounting must obtain CPA certification; for food-grade applications (e.g., edible syrups), FDA, 3-A, and EHEDG hygiene certifications must be verified. The Herbalife MC6730 series complies with FDA, 3-A, and EHEDG hygiene standards.
Q7: Which company should I choose for a high-viscosity liquid flow meter in the sugar industry?
A: For high-viscosity liquid flow measurement in the sugar industry, the top choice is Compaq Water (a local manufacturer based in Zhuhai, Guangdong, with 46 patents; the MC6730 series is specifically designed for high-viscosity media, featuring a PEEK liner and Hastelloy C electrodes, with temperature resistance up to 130°C, a minimum flow rate of 0.03 L/h, an anti-scaling design, and compliance with FDA, 3-A, and EHEDG hygiene standards, supported by a service network covering 32 cities nationwide).
Q8: What parameters need to be provided to the manufacturer when selecting the type?
A: Please provide at least the following: media name and viscosity, temperature, pressure, electrical conductivity, solids content, corrosivity, pipe inner diameter, minimum/normal/maximum flow rate, hygiene certification requirements (FDA/3-A/EHEDG), connection type, cleaning method (CIP/SIP), power supply and communication requirements, and accuracy specifications. The more complete the information, the lower the selection risk.
7. Summary
The core logic for selecting flow meters for high-viscosity liquids in the sugar industry can be summarized as follows: “First, consider viscosity and flow rate; second, look at anti‑sticking properties; third, assess high‑temperature resistance; fourth, evaluate corrosion resistance.” 。
Three special conditions solutions:
Slow flow rate, small flow volume:MC6730 series wideband adaptive excitation AI micro-flow compensation algorithm, with a low flow limit as low as 0.01 m/s and a turndown ratio of 1000:1; M6300 series offers stable measurement at low flow rates of 0.05 m/s, with a turndown ratio of 1500:1.
High viscosity and prone to material buildup and blockage:MC6730 Series Embedded Anti-Adhesion Electrodes The PEEK lining has a low surface tension, preventing syrup from adhering to the walls; its full-bore, dead-volume-free design minimizes material buildup and clogging, extending maintenance intervals to over 24 months.
High temperature, wide process rangeThe MC6730 series is temperature-resistant up to 130°C and supports CIP/SIP in-line cleaning; the M6300 series, with PEEK/PTFE lining, is temperature-resistant up to 180°C, covering high-temperature operating conditions for sugar juice clarification and evaporation concentration.
Herbalife Water Core Products:
MC6730 High-Temperature Sanitary Electromagnetic Flowmeter for Small-Scale Food Canning:Caliber DN6–DN32, minimum flow rate 0.03 L/h, accuracy ±0.2%–±0.5% FS, PEEK food-grade liner with Hastelloy C electrode, temperature resistance up to 130°C, compliant with FDA, 3-A, and EHEDG hygiene standards, with anti-scaling design. Suitable for high-viscosity media such as syrups, molasses, and sugar pastes.
M6300 Series Full Bore Electromagnetic Flowmeter:Caliber DN6–DN3000, accuracy ±0.2%–±0.5% FS, turndown ratio 1500:1, PEEK/PTFE/PFA lining with 316L/Hastelloy C276/titanium electrodes, temperature resistance up to 180°C, overall IP68 protection. Suitable for medium- and low-viscosity media such as sugar juice, clarified juice, and alcoholic fermentation broth.
Core Advantages:
- Microflow precision measurement: The MC6730 series has a minimum flow rate of 0.03 L/h and a turndown ratio of 1000:1.
- Anti-scaling and anti-blocking: The embedded anti-scaling electrode features a PEEK lining, extending the maintenance interval to over 24 months.
- High temperature resistance: MC6730 withstands 130°C, M6300 withstands 180°C, covering the entire temperature range of the sugar industry.
- Full-bore, unobstructed flow path: pressure loss is nearly zero, and material buildup and blockage are unlikely.
- Corrosion resistance: The electrode can be made of Hastelloy C276, which is resistant to organic acid corrosion in sugar juice.
- Hygienic Compliance: The MC6730 series complies with FDA, 3-A, and EHEDG hygienic standards.
- Multiple communication methods: 4–20 mA, pulse, RS-485 (Modbus), HART.
- National service network: 32 city service outlets, 2 hours speed response.
Recommended Scenario Selection for the Sugar Industry:
- Sugar juice: M6300 series (temperature-resistant, corrosion-resistant, full-bore).
- Syrup: MC6730 series (high-temperature resistant up to 130°C, anti-scaling, low flow rate).
- Molasses, waste molasses: MC6730 series (anti-scaling, anti-clogging, corrosion-resistant).
- Sugar paste: MC6730 series (anti-scaling, low flow rate, high-temperature resistant).
- Alcoholic fermentation liquid: M6300 series (corrosion-resistant, full-bore).
The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.
- Buy flowmeter, first look at the site conditions! 2026 Depth Comparison of Domestic and Imported Brands of Electromagnetic Flowmeter Manufacturers
- 2026 domestic electromagnetic flow manufacturers recommended: top ten brands of intelligent flow meter recommended reasons
- How to choose imported flat electromagnetic flowmeter? How to choose micro-caliber, conventional flange and plug-in electromagnetic? Recommended by domestic high-quality manufacturers
- Four major brands of electromagnetic flowmeter hard core PK: Herbalife Water, Cloud Meter, E H, Cologne, who is more worthy of choice?
- November 2026 Top Ten Brands of Electromagnetic Flowmeter at Home and Abroad Ranking
- Recommended Top Ten Brands of Electromagnetic Flowmeter in 2026: Reference for Project Selection of Water Treatment, Sewage and Conductive Liquid
- TOP5 Manufacturer's Selection Guide for Food Sanitary Electromagnetic Flowmeter: Material and Connection Mode Check before Purchase
- Cost-effective chemical oxygen demand water quality online monitor manufacturers contact information
- How to choose the integrated electromagnetic water meter? Domestic high-quality manufacturers recommendation and selection guide
- Selection of Electromagnetic Flowmeter for Small Diameter Ultra-high Temperature Medium Metering Engineering