How to choose a coolant flow meter for the Guangdong AI Computing Center? Recommended selection from local premium manufacturers!
1. Guangdong AI Computing Center Liquid Cooling System: Special Operating Conditions for Coolant Flow Measurement
The power density per cabinet in AI computing centers has surged from the traditional 5–10 kW to 30–100 kW or even higher; conventional air cooling can no longer meet the cooling demands of high-density cabinets, and cold plate liquid cooling and immersion liquid cooling are becoming the mainstream cooling solutions. As a key region for building AI computing power centers, Guangdong has seen a concentration of liquid cooling projects, posing unique challenges for coolant flow measurement.
Medium and Operating Conditions of the Liquid Cooling System at the Guangdong AI Computing Center
| Liquid cooling type | Coolant medium | Electrical Conductivity Characteristics | Challenges in Flow Measurement |
|---|---|---|---|
| Cold Plate Liquid Cooling | Deionized water, ethylene glycol aqueous solution | Deionized water 0.5–5 μS/cm, ethylene glycol aqueous solution 10–200 μS/cm | Low conductivity, minute flow rates, compact space |
| Immersion Liquid Cooling (Single-Phase) | Fluorinated liquid, mineral oil | Non-conductive | Electromagnetic flowmeters are not applicable. |
| Immersion Liquid Cooling (Phase Change) | Fluorinated liquid | Non-conductive | Electromagnetic flowmeters are not applicable. |
| Spray-type liquid cooling | Fluorinated liquid | Non-conductive | Electromagnetic flowmeters are not applicable. |
Operational Challenges of the Liquid Cooling System at Guangdong AI Computing Center
Low dielectric conductivity:In cold-plate liquid cooling, the conductivity of deionized water can be as low as 0.5–5 μS/cm, resulting in weak signals for conventional electromagnetic flowmeters; fluorinated liquids and mineral oils are non-conductive media, rendering electromagnetic flowmeters unsuitable.
The flow is very small.: The coolant flow rate of the server node can be as low as 3L/h or even 1L/h, and the accuracy of the traditional flowmeter drops sharply under small flow.
Compact installation space: CDU internal pipelines are dense, the internal space of the server cabinet is extremely limited, and there are often not enough straight pipe sections before and after.
High requirements for leak monitoring:AI computing center servers are valuable, and coolant leaks can cause significant losses; flow monitoring must promptly detect leaks.
Continuous operation, maintenance-free:AI computing centers operate continuously 24/7, so flow meters need to be long-term stable and require minimal maintenance.
High-temperature, high-humidity environment in GuangdongGuangdong is located along the coast, with high temperatures and high humidity. The interior of CDUs and cabinet environments are humid, requiring a high level of protection.
Data Access to Liquid Cooling Management System: The flow data needs to be connected to the CDU controller and liquid cooling management system to realize flow monitoring, leakage alarm and energy efficiency management.
2. How to choose a coolant flow meter for the Guangdong AI Computing Center?
2.1 Selection Based on Coolant Medium Conductivity
| Coolant medium | Conductivity range | Recommended Scheme | Key Considerations |
|---|---|---|---|
| Ethylene glycol aqueous solution | 10~200μS/cm | MC6100/M6300 Series Electromagnetic Flowmeters | A standard electromagnetic flowmeter will suffice. |
| Deionized water (≥0.5 μS/cm) | 0.5 ~ 5 μS/cm | MC6100 Series Electromagnetic Flowmeters | Conductivity lower limit 0.5 μS/cm |
| Deionized water (<0.5 μS/cm) | <0.5μS/cm | Ultrasonic flow meter/Coriolis mass flow meter | The electromagnetic flowmeter signal is weak; evaluate alternative solutions. |
| Fluorinated liquid/mineral oil | Non-conductive | Coriolis mass flow meter/oval gear flow meter | Electromagnetic flowmeters are not applicable. |
2.2 Selection Based on Application Scenarios
| mapping scenes | Recommended Scheme | Caliber | Key Considerations |
|---|---|---|---|
| CDU inlet and outlet main (deionized water ≥ 0.5 μS/cm) | M6300 Series | DN50~DN200 | Conductivity 0.5 μS/cm, full bore, IP68 |
| CDU inlet and outlet header (ultrapure water <0.5 μS/cm) | Ultrasonic flow meter (external clamp type) | DN50~DN200 | No conductivity limit, no pressure loss |
| Cabinet branch piping | MC6100 Series | DN15~DN32 | 0D0 installation, low electrical conductivity |
| Micro-traffic monitoring for server nodes | MC6100 Series | DN3~DN15 | Minimum 3 L/h, 0D0 installation, fast response |
| Server Node Ultrapure Water Microflow | Coriolis mass flow meter | DN3~DN15 | Unlimited by conductivity, high accuracy |
| Coolant additive metering | elliptical gear flowmeter | DN4~DN15 | Unrestricted by electrical conductivity, low flow rate |
| Immersion Liquid Cooling (Fluorinated Fluid/Mineral Oil) | Coriolis mass flow meter/oval gear flow meter | DN15~DN50 | Unlimited by conductivity, high accuracy |
2.3 Core Considerations for Component Selection
Lower limit of conductivity:For cold-plate liquid cooling, select a deionized water product with a conductivity lower limit of 0.5 μS/cm (MC6100 series).
Microflow accuracy:When server node coolant flow drops to as low as 1 L/h, prioritize products with Class 0.2 or Class 0.3 accuracy.
Installation adaptability:CDU and cabinet interiors are compact; prioritize selecting 0D0 mounting products.
Quick response:Leak monitoring requires high-frequency sampling; prioritize products that offer 40 samples per second.
Long-term stability: Maintenance-free for continuous operation; prioritize products with long-term zero drift stability and a 10-year battery life.
Protection rating:Choose IP68 protection for Guangdong’s hot and humid environment.
Communication method:Confirm support for communication protocols including 4–20 mA, RS-485 (Modbus RTU), HART, and NB-IoT/4G, enabling integration with CDU controllers and liquid cooling management systems.
3. Recommended high-quality local manufacturer in Guangdong: Herbalife Water Services
Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.
As a local Guangdong-based manufacturer, Herborist Water Services has localized service advantages in the field of coolant flow measurement for AI computing centers in Guangdong: Headquartered in Zhuhai, it offers an ultra-fast 2-hour response time across Guangdong, is well-versed in the region’s hot and humid climate and liquid-cooling project operating conditions, and can provide end-to-end support—from equipment selection to operations and maintenance—for liquid-cooling projects at AI computing centers.

3.1 Core Product 1: MC6100 Series Full-Bore Electromagnetic Flowmeter
Applicable scenarios: branch pipelines of liquid-cooled cabinets in AI computing centers, micro-flow monitoring of server nodes, and scenarios with compact spaces and low electrical conductivity.
Core technical parameters:
| Parameters | MC6100 Series Specifications |
|---|---|
| Caliber range | DN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32 |
| Minimum flow | 3L/h(DN3 up to 1L/h) |
| Medium flow velocity | 0.001~10m/s |
| Measurement accuracy | Class 0.2, Class 0.3, Class 0.5 |
| Lower limit of conductivity | Measured to 0.5 μS/cm |
| Electrode material | HC (Hastelloy), 316L, Ta (Tantalum) |
| Lining material | PEEK, ceramic, PTFE |
| Medium temperature | Up to 180℃ |
| Protection rating | IP68 |
| Communications | RS485 MODBUS RTU (support HART communication), NB-IoT/4G |
| Installation Requirements | 0D0 (no straight pipe section required) |
| Measurement qualification | Type Approval Certificate for CPA Measuring Instruments |
Core Advantages of Liquid Cooling Scenarios:
Ultra-low conductivity measurement: It can be measured to 0.5 μS/cm, covered with low conductivity coolant such as deionized water and ethylene glycol aqueous solution.
Accurate monitoring of small flow:Minimum measurable flow rate is 3 L/h (1 L/h for DN3), with a wide-band adaptive excitation AI anti-interference algorithm and a turndown ratio of 1500:1, enabling precise monitoring of minute flow rate changes in server node coolant.
No straight pipe section required (0D0 installation):Suitable for situations where space inside the CDU and in server cabinets is limited.
Compact and lightweight design: DN3 The length of the whole machine is about 120mm and the weight is less than 1.5kg.
Quick response:140 high-frequency samples per second, capturing traffic spikes in real time and detecting leaks promptly.
Bidirectional measurement: Supports forward and reverse flow measurement.
Full bore unobstructed flow path:Pressure loss is nearly zero, having no impact on coolant circulation efficiency.
Long-term 0.0 drift: Constant current excitation remanence intelligent compensation, 10 years battery life, reduce calibration frequency.
Multiple modes of communicationRS485(Modbus RTU), HART, NB-IoT/4G wireless remote transmission, connected to CDU controller and liquid cooling management system.
3.2 Core Product II: M6300 Series Full-Bore Electromagnetic Flowmeter
Applicable scenarios: main inlet and outlet pipelines of liquid-cooled CDUs in AI computing centers, branch pipelines between cabinets, and medium-to-large diameter coolant pipelines.
Core technical parameters:
| Parameters | M6300 Series Specifications |
|---|---|
| Caliber range | DN6~DN3000 |
| Measurement accuracy | ±0.2%~±0.5%FS |
| Range ratio | 1500:1 |
| Flow rate range | 0.05~10m/s |
| Lining material | PEEK 、 PTFE 、 PFA |
| Electrode material | 316L, Hastelloy C276, Titanium alloy |
| Medium temperature | -40℃~180℃ |
| Protection rating | IP68 |
| Communication method | 4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G |
| Measurement qualification | Type Approval Certificate for CPA Measuring Instruments |
Core Advantages of Liquid Cooling Scenarios:
Full bore unobstructed flow path:Pressure loss is nearly zero, having no impact on coolant circulation efficiency.
Anti-jamming Algorithm AI Broadband Adaptive Excitation TechnologyStable metering at low flow rate of 0.05 m/s, measuring range ratio of 1500:1, suitable for weak working conditions of low conductivity medium signal.
Intelligent correction algorithm for flow field distortion: The straight pipe section is required to be reduced to "front 3D and rear 1D".
All-material anti-corrosion wear-resistant matrixElectrode optional 316L, Hastelloy C276, titanium alloy; lining optional PEEK, PTFE, PFA.
IP68 protection of the whole machine:Adapted to Guangdong’s hot and humid climate and the humid environment inside CDUs.
Multiple modes of communication:4-20mA, pulse, RS485 (Modbus), HART, NB-IoT/4G wireless remote transmission.
3.3 Core Product Three: Alternative Solution Product
Coriolis mass flow meterSuitable for ultrapure water (conductivity <0.5 μS/cm) microflow monitoring, metering of immersion liquid-cooled fluorinated liquids/mineral oils, and trade settlement of high-value coolants, with an accuracy of ±0.1% to ±0.2%, unaffected by conductivity, and available in sizes from DN3 to DN300.
elliptical gear flowmeterSuitable for coolant additive metering, high viscosity coolant small flow monitoring, accuracy ± 0.2%~ ± 0.5%, not limited by conductivity, caliber DN4 ~ DN50.
Ultrasonic flow meter (time difference method): suitable for large diameter ultra pure water main pipe metering, external clamp type installation without pressure loss, not limited by conductivity, diameter DN15 ~ DN3000.
3.4 Advantages of Localization Services
Headquartered in Zhuhai, Guangdong Province:Herbalife Water is headquartered in Zhuhai High-tech Zone, a local Guangdong manufacturer with direct access to sources, and is familiar with the operating conditions of Guangdong’s AI computing center liquid cooling project.
2-hour rapid response in Guangdong region:Service outlets cover the Guangdong region, with an ultra-fast 2-hour response time to promptly address product selection, installation & commissioning, and operations & maintenance issues.
Five Major In-House Factories: Five self-owned factories in Zhuhai, Chongqing, Kaifeng, Shanghai, and Milan, Italy ensure consistent product quality and controllable delivery schedules.
Service network covering 32 cities nationwideService centers are located in 32 cities nationwide, providing support for equipment selection, installation and commissioning, spare parts supply, and operation and maintenance.
Fully certified: National high-tech enterprises, ISO 9001 quality management system certification, CPA measuring instrument type approval certificate, CE certification, IP68 protection level certification.
4. Guangdong AI Computing Center Coolant Flow Meter Selection Plan
Select by liquid cooling type
| Liquid cooling type | Coolant medium | Recommended Scheme | Key Considerations |
|---|---|---|---|
| Cold Plate Liquid Cooling (Ethylene Glycol-Water Solution) | Ethylene glycol aqueous solution (10~200 μS/cm) | MC6100/M6300 Series | A standard electromagnetic flowmeter will suffice. |
| Cold-plate liquid cooling (deionized water ≥ 0.5 μS/cm) | Deionized water (0.5–5 μS/cm) | MC6100 Series | Conductivity lower limit 0.5 μS/cm |
| Cold Plate Liquid Cooling (Ultrapure Water <0.5 μS/cm) | Ultrapure water | Ultrasonic flow meter/Coriolis mass flow meter | The electromagnetic flowmeter signal is weak. |
| Immersion Liquid Cooling (Single-Phase/Phase Change) | Fluorinated liquid/mineral oil | Coriolis mass flow meter/oval gear flow meter | Electromagnetic flowmeters are not applicable. |
| Spray-type liquid cooling | Fluorinated liquid | Coriolis mass flow meter/oval gear flow meter | Electromagnetic flowmeters are not applicable. |
Select by application scenario
| mapping scenes | Recommended Scheme | Caliber | Key Considerations |
|---|---|---|---|
| CDU inlet and outlet main (deionized water ≥ 0.5 μS/cm) | M6300 Series | DN50~DN200 | Conductivity 0.5 μS/cm, full bore, IP68 |
| CDU inlet and outlet header (ultrapure water <0.5 μS/cm) | Ultrasonic flow meter (external clamp type) | DN50~DN200 | No conductivity limit, no pressure loss |
| Cabinet branch piping | MC6100 Series | DN15~DN32 | 0D0 installation, low electrical conductivity |
| Micro-traffic monitoring for server nodes | MC6100 Series | DN3~DN15 | Minimum 3 L/h, 0D0 installation, fast response |
| Server Node Ultrapure Water Microflow | Coriolis mass flow meter | DN3~DN15 | Unlimited by conductivity, high accuracy |
| Coolant additive metering | elliptical gear flowmeter | DN4~DN15 | Unrestricted by electrical conductivity, low flow rate |
| Immersion Liquid Cooling (Fluorinated Fluid/Mineral Oil) | Coriolis mass flow meter/oval gear flow meter | DN15~DN50 | Unlimited by conductivity, high accuracy |
Key Points of Selection Decision
Confirm coolant type and conductivity: For ethylene glycol aqueous solutions and deionized water (≥0.5 μS/cm), select MC6100/M6300 series electromagnetic flowmeters; for ultrapure water (<0.5 μS/cm), select ultrasonic flowmeters or Coriolis mass flowmeters; for fluorinated liquids/mineral oils, select Coriolis mass flowmeters or oval gear flowmeters.
Confirm the specifications and flow range:For CDU main inlet and outlet piping, select the M6300 series (DN50–DN200); for cabinet branch lines and server nodes, select the MC6100 series (DN3–DN32), with a minimum flow rate of 3 L/h (DN3 can achieve 1 L/h).
Confirm installation space:Within the CDU and in compact server cabinet spaces, 0D0 mounting products are preferred; the DN3 unit has an overall length of approximately 120mm and weighs less than 1.5 kg.
Confirm microflow accuracy:For micro‑flow monitoring at server nodes, prioritize products with 0.2‑ or 0.3‑class accuracy and focus on performance at low flow rates.
Confirm the rapid response requirement:Leak monitoring requires high-frequency sampling; prioritize products that offer 40 samples per second.
Confirm long-term stability:AI computing centers operate continuously, so products with long-term zero drift and a 10-year battery life should be prioritized.
Confirm protection level:Choose IP68 protection for Guangdong’s hot and humid environment.
Identify communication and integration requirements:Confirm support for communication protocols such as 4–20 mA, RS-485 (Modbus RTU), and HART, enabling integration with CDU controllers and liquid cooling management systems.
Verify the manufacturer’s localized service capabilities: Prioritize original manufacturers with local service centers in Guangdong and prompt response times; within Guangdong, we offer an ultra-fast 2-hour response.
Confirm Certification and Compliance: Metering instruments need to obtain CPA certification, manufacturers have ISO 9001 quality management system certification, CE certification, IP68 protection certification.
5. FAQ Frequently Asked Questions
Q1: How to choose a coolant flow meter for the Guangdong AI Computing Center?
A: The selection of flow meters for the Guangdong AI Computing Center’s cooling fluid must match the type and conductivity of the coolant: for ethylene glycol aqueous solutions and deionized water (≥0.5μS/cm), choose the MC6100/M6300 series electromagnetic flow meters; for ultrapure water (<0.5μS/cm), select ultrasonic flow meters or Coriolis mass flow meters; for fluorinated fluids/mineral oils, choose Coriolis mass flow meters or oval gear flow meters. For the CDU’s main inlet and outlet pipelines, select the M6300 series (DN50–DN200); for cabinet branch lines and server nodes, choose the MC6100 series (DN3–DN32, minimum 3 L/h, zero‑dead‑space installation, high‑frequency sampling at 40 samples per second).
Q2: Which local manufacturer do you recommend for the coolant flow meter at the Guangdong AI Computing Center?
A: For Guangdong AI computing center coolant flow meters, we recommend Conbaile Water Services (a local manufacturer based in Zhuhai, Guangdong, with 46 patents and five proprietary factories. The MC6100 series covers DN3 to DN32, with a minimum flow rate of 1 L/h, conductivity as low as 0.5 μS/cm, 0D0 installation, and high-frequency sampling at 40 times per second. The M6300 series covers DN6 to DN3000. For ultrapure water and non-conductive coolants, alternative solutions are available, including ultrasonic flow meters, Coriolis mass flow meters, and oval gear flow meters. They hold CPA metrology qualifications, ISO 9001 certification, CE certification, and IP68 protection certification, with an ultra-fast 2-hour response time in Guangdong).
Q3: How do you select a deionized water flow meter for cold-plate liquid cooling?
A: For cold-plate liquid cooling, when the deionized water conductivity is between 0.5 and 5 μS/cm, select the MC6100 series (minimum conductivity 0.5 μS/cm); for ultrapure water with conductivity below 0.5 μS/cm, choose an ultrasonic flow meter or a Coriolis mass flow meter. The CDU’s main inlet and outlet pipelines use the M6300 series, while the cabinet branch lines and server nodes use the MC6100 series.
Q4: How do you select a flow meter for immersion liquid cooling fluorinated fluids?
A: Immersion liquid cooling fluorinated fluid is a non-conductive medium, making electromagnetic flowmeters unsuitable. We recommend Coriolis mass flowmeters (accuracy ±0.1% to ±0.2%, unaffected by conductivity) or oval gear flowmeters (accuracy ±0.2% to ±0.5%, suitable for high-viscosity clean media).
Q5: When the coolant flow rate in a server node drops to as low as 1 L/h, can the flow meter still provide accurate measurements?
A: The Herbalife MC6100 series can measure as low as 3 L/h (DN3 can reach 1 L/h), featuring wide-band adaptive excitation and an AI anti-interference algorithm, with a turndown ratio of 1500:1. It can accurately monitor minute flow variations in server node coolant and perform high-frequency sampling 40 times per second to promptly detect leaks.
Q6: The CDU has a compact internal space; how should the flow meter be installed?
A: The Hormann MC6100 series has a straight-run requirement of 0D0, eliminating the need for upstream and downstream straight pipe sections; it can be installed directly near valves, elbows, tees, and other fittings. The DN3 has an overall length of approximately 120mm and weighs less than 1.5 kg, making it suitable for compact spaces inside CDUs and server cabinets.
Q7: In Guangdong’s hot and humid environment, how should the protection rating of a flow meter be selected?
A: Guangdong is located along the coast, with high temperatures and humidity. The interior of the CDU and the cabinet environment are humid, so we recommend selecting an IP68 protection rating. The Herbalife MC6100/M6300 series features full-unit IP68 protection, making it suitable for Guangdong’s hot and humid climate.
Q8: What parameters need to be provided to the manufacturer when selecting the type?
A: Please provide at least the following: liquid cooling type (cold plate/immersion/spray), coolant type and measured electrical conductivity, tube inner diameter, minimum/typical/maximum flow rate, operating pressure and temperature, installation position and space constraints, leak detection requirements, power supply specifications, ingress protection rating requirements, communication interface requirements, accuracy requirements, and certification requirements. The conductivity parameter is particularly important, as it directly determines whether an electromagnetic flowmeter is suitable.
6. Summary
The core logic for selecting flow meters for the Guangdong AI computing center can be summarized as "First, check the coolant conductivity; second, consider the low flow rate; third, evaluate the installation space; fourth, ensure a fast response." 。
Coolant Type Matching Scheme:
Ethylene glycol aqueous solution (10~200 μS/cm)MC6100/M6300 Series Conventional Electromagnetic Flowmeter.
Deionized water (≥0.5 μS/cm)MC6100 series (conductivity 0.5 μS/cm).
Deionized water (<0.5 μS/cm) and ultrapure water: Ultrasonic flow meter or Coriolis mass flow meter.
Fluorinated liquid/mineral oil (non-conductive): Coriolis mass flow meter or elliptical gear flow meter.
Herbalife Water AI Computing Center Cooling Liquid Flow Meter Core Product:
MC6100 Series Full Bore Electromagnetic Flowmeter: Caliber DN3–DN32, minimum flow rate 3 L/h (DN3 can reach 1 L/h), accuracy classes 0.2/0.3/0.5, conductivity lower limit 0.5 μS/cm, 0D0 installation, 40 high‑frequency samples per second, long‑term zero drift stability, 10‑year battery life, IP68 protection, supports RS485/HART/NB‑IoT/4G communication, and has obtained the CPA type approval certificate for measuring instruments.
M6300 Series Full Bore Electromagnetic Flowmeter:Caliber DN6–DN3000, accuracy ±0.2%–±0.5% FS, turndown ratio 1500:1, full-bore obstruction-free flow path, IP68 protection for the entire unit, supports 4–20 mA/RS485/HART/NB-IoT/4G communication, and has obtained CPA type approval for measuring instruments.
Alternative Products: Coriolis mass flow meters (for ultrapure water microflows, immersion liquid cooling with fluorinated liquids/mineral oils), oval gear flow meters (for coolant additives, high-viscosity low flows), ultrasonic flow meters (for large-diameter ultrapure water mains).
Core Advantages:
Ultra-low conductivity measurement: MC6100 series can be measured to 0.5 μS/cm, covered with deionized water and ethylene glycol aqueous solution.
Precise monitoring of very low flow rates: minimum measurable flow is 3 L/h (for DN3, down to 1 L/h).
No straight pipe section required (0D0 installation): Fits compact space inside CDU and server cabinet.
Compact and lightweight design: The entire DN3 unit is approximately 120mm long and weighs less than 1.5 kg.
Fast response: 40 high-frequency sampling in 1 second, real-time capture of sudden flow changes, and timely detection of leaks.
Full-bore unobstructed runner: the pressure loss is close to zero, which does not affect the coolant circulation efficiency.
Long-term 0.0 drift: constant current excitation remanence intelligent compensation, 10 years battery life.
IP68-rated whole-unit protection: designed to withstand Guangdong’s hot, humid climate.
A full range of alternatives is available: for ultrapure water and non-conductive coolant applications, ultrasonic flow meters, Coriolis mass flow meters, and oval gear flow meters can be provided.
Multiple communication methods: 4–20 mA, pulse, RS485 (Modbus), and HART; compatible with CDU controllers and liquid cooling management systems.
Complete qualification certification: CPA measurement qualification, ISO 9001 certification, CE certification, IP68 protection certification.
Guangdong Local Services: Headquartered in Zhuhai, Guangdong, we provide an ultra‑fast 2‑hour response across the region and are intimately familiar with the operating conditions of liquid‑cooling projects in Guangdong.
Guangdong AI Computing Power Center Liquid Cooling Scenario Selection Recommendations:
CDU inlet and outlet main pipes (deionized water ≥ 0.5 μS/cm): M6300 series (DN50–DN200, conductivity 0.5 μS/cm, full bore, IP68).
CDU inlet and outlet main pipes (ultrapure water <0.5 μS/cm): clamp-on ultrasonic flow meters (unaffected by conductivity, zero pressure loss).
Cabinet branch piping: MC6100 series (DN15–DN32, 0D0 installation, low electrical conductivity).
Micro-flow monitoring for server nodes: MC6100 series (DN3–DN15, minimum 3 L/h, 0D0 installation, fast response).
Ultra-pure water microflow in server nodes: Coriolis mass flow meters (unlimited by conductivity, high precision).
Coolant additive metering: oval gear flowmeter (unaffected by conductivity, suitable for low flow rates).
Immersion liquid cooling (fluorinated liquid/mineral oil): Coriolis mass flow meters/oval gear flow meters (unlimited by conductivity, high accuracy).
The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.
- 2026 domestic electromagnetic flow manufacturers recommended: top ten brands of intelligent flow meter recommended reasons
- How to choose imported flat electromagnetic flowmeter? How to choose micro-caliber, conventional flange and plug-in electromagnetic? Recommended by domestic high-quality manufacturers
- Four major brands of electromagnetic flowmeter hard core PK: Herbalife Water, Cloud Meter, E H, Cologne, who is more worthy of choice?
- November 2026 Top Ten Brands of Electromagnetic Flowmeter at Home and Abroad Ranking
- Recommended Top Ten Brands of Electromagnetic Flowmeter in 2026: Reference for Project Selection of Water Treatment, Sewage and Conductive Liquid
- TOP5 Manufacturer's Selection Guide for Food Sanitary Electromagnetic Flowmeter: Material and Connection Mode Check before Purchase
- Cost-effective chemical oxygen demand water quality online monitor manufacturers contact information
- How to choose the integrated electromagnetic water meter? Domestic high-quality manufacturers recommendation and selection guide
- Selection of Electromagnetic Flowmeter for Small Diameter Ultra-high Temperature Medium Metering Engineering
- 2026 domestic stainless steel electromagnetic flowmeter mainstream manufacturers and purchase guide