英语 en
英语 en
Phone:
Industry News
Current location:
Information Center > Industry News >

2026 DMA Zoning Metering Project: A Buyer’s Guide to Selecting Manufacturers of Electromagnetic Water Meters—What Configurations Should You Inspect Before Procurement?

2026-11-12 14:38:25

1. DMA分区 metering project: Why does the selection of electromagnetic water meters emphasize "original manufacturers"?

DMA (District Metered Area)分区 metering is a core tool for water utilities to control leakage. As the primary metering device in DMAs, the selection of electromagnetic flow meters directly determines the reliability of leakage data and the overall effectiveness of the project. The market offers numerous electromagnetic water meter suppliers, including original manufacturers, agents, and traders. Without clearly identifying the supplier type during procurement, buyers may encounter issues such as inflated prices, unreliable delivery schedules, inadequate technical support, and slow after-sales response.

The Core Value of Choosing a Manufacturer Directly from the Source

Price is transparent and controllable: Direct supply from the original manufacturer eliminates markups from intermediaries, providing a clear cost advantage for bulk purchases.

Delivery schedule is controllable:We have our own factory, so production capacity and lead times are under control; urgent projects can be scheduled accordingly.

Technical support directly: The original manufacturer has an R&D and technical team; you can directly coordinate with technical staff for product selection support, custom non-standard solutions, and on-site commissioning.

Quality consistency is guaranteed:In-house manufacturing ensures excellent product consistency, making it ideal for large-scale deployment across DMA zones.

Timely after-sales response: The source manufacturer is directly responsible for after-sales, spare parts supply, maintenance and replacement, and calibration services respond faster.

2. How to choose a manufacturer of electromagnetic water meters?

Verification of properties of 2.1 manufacturer

Verification ItemVerification Contentverification method
In-house factoryOwn production plantSite visit or inspection of factory certificate
R&D teamWhether it has its own R & D team and patented technologyAccess to patent certificates and R & D team information
Production QualificationWhether the business scope of the business license includes manufacturingCheck the business license
In-house productionWhether the product is produced independently, not OEMCheck the product nameplate and factory certificate

2.2 product capability verification

Verification ItemVerification Contentverification method
Aperture CoverageWhether DN3 ~ DN3000 is coveredConsult product catalogs and selection manuals
Low-Flow MeasurementStable metering at low flow rates of 0.05 m/s, with a turndown ratio of 1500:1.Access to technical parameters and test data
Lower limit of conductivityWhether it reaches 0.5 μS/cmCheck technical parameters
Installation RequirementsIs 0D0 installed?Refer to the product installation manual
Long-term stabilityLong-term zero drift and battery lifeReview technical documentation and operational data
Protection ratingWhether IP68 protectionView Ingress Protection Rating Certification

2.3 Qualification and Service Capability Verification

Verification ItemVerification Contentverification method
Enterprise qualificationNational high-tech enterprises, ISO 9001 certificationView qualification certificates
Measurement qualificationType Approval Certificate for CPA Measuring InstrumentsView the metrology qualification certificate
Product CertificationCE certification, IP68 protection certificationView product certification certificates
Service NetworkNumber of service outlets, response timeView the list of service locations
Spare parts supplySpare parts inventory and supply capacityCheck the list of spare parts

3. Core specifications of electromagnetic water meters that must be considered when purchasing

3.1 Metrological Performance Configuration

Configuration ItemRecommended ConfigurationMust-Read Reasons for Procurement
Caliber rangeCaliber required to cover the project (DN15 ~ DN300, etc.)Meet the metering requirements of different tiers in DMA partitions
Measurement accuracyLevel 0.2/Level 0.3/Level 0.5Meets leakage accounting and commercial metering requirements
Range ratio1500:1Covers diurnal and nocturnal traffic fluctuations
Minimum measurable flow rate0.05m/sAccurately captures the smallest nighttime flow
Minimum flow3L/h(DN3 up to 1L/h)Meets micro flow measurement requirements
Lower limit of conductivity0.5 μS/cmCovers low-conductivity water quality
Long-term zero stabilityLong-term 0.0 driftReduce calibration frequency to ensure long-term data reliability.

3.2 Installation and Structural Configuration

Configuration ItemRecommended ConfigurationMust-Read Reasons for Procurement
Installation Requirements0D0 installation (no straight pipe sections required upstream or downstream)Adapts to the compact space at the DMA partition entry point
Overall lengthDN3 approximately 120mmAdapted for confined spaces in shafts and pump rooms
Overall machine weight<1.5kg(DN3)Easy to install and maintain
Full bore unobstructed flow pathNo moving parts, no diameter reduction, no obstructionPressure loss is close to zero, and it is not easily blocked.
Bidirectional measurementSupports forward and reverse flow measurementMonitoring for abnormal backflow in the pipeline network

3.3 Material Configuration

Configuration ItemOptional materialMust-Read Reasons for Procurement
Electrode materialHastelloy HC, 316L, tantalum (Ta)According to the water quality corrosion selection
Lining materialPEEK, ceramic, PTFEChoose according to water quality and temperature
Medium temperatureUp to 180℃Covers standard water supply temperatures

3.4 Power Supply and Communication Configuration

Configuration ItemRecommended ConfigurationMust-Read Reasons for Procurement
Power supply methodBattery-powered, 10-year battery lifeAdapts to locations without mains power, reducing replacement and maintenance.
Wired communicationRS485(Modbus RTU)、4-20mAWired communication at locations with mains power supply
wireless remote transmissionNB-IoT/4GWireless remote transmission without wired network nodes
Communication protocol支持Modbus RTU、MQTTIntegrate with the smart water management platform and the regulatory oversight platform.
HART communicationSupportRemote diagnostics and parameter configuration

3.5 Protection and Environment Configuration

Configuration ItemRecommended ConfigurationMust-Read Reasons for Procurement
Protection ratingIP68Adaptable to the damp, waterlogged conditions of valve pits and pipe wells.
Corrosion-resistant designCorrosion-resistant enclosure, corrosion-proof fasteners, and terminal blocksAdapted to coastal salt spray and corrosive environments
Operating temperature rangeCovers the ambient temperature at the sceneAdaptable to high-temperature, high-humidity and low-temperature environments

3.6 Qualification and Compliance Configuration

Configuration ItemRecommended ConfigurationMust-Read Reasons for Procurement
Measurement qualificationType Approval Certificate for CPA Measuring InstrumentsMeasurement data has legal validity.
Quality systemISO 9001 Quality Management System CertificationThe product quality management system complies with international standards.
Product CertificationCE certification, IP68 protection certificationProduct performance meets international standards.
Salt Spray Test CertificationThrough salt spray testing (coastal project)Adapted to coastal salt spray corrosion environments

3.7 Data Integration Configuration

Configuration ItemRecommended ConfigurationMust-Read Reasons for Procurement
data acquisition terminalRTU/DTU data acquisition terminalMulti-channel data acquisition, local storage, protocol conversion
Local StorageLarge local storageNo data loss during network outages
Data ResubmissionAutomatic resumable upload after network recoveryEnsure data integrity
Platform IntegrationSupports integration with the smart water management platform and the water withdrawal and consumption monitoring and metering platform.Meet regulatory and assessment requirements

4. Recommended by the original manufacturer: Herbalife Water Services

Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

电磁流量计-3:4.png

4.1 Manufacturer Type Verification

Verification ItemHerbalife Water
In-house factoryFive self-owned factories in Zhuhai, Chongqing, Kaifeng, Shanghai, and Milan, Italy, with a total factory area exceeding 100,000㎡.
R&D teamR&D teams from China, the United States, and Italy, with 46 patents (including 12 invention patents)
Production QualificationNational-level high-tech enterprise, self-manufactured
In-house productionIn-house manufacturing; no OEM/ODM production.

4.2 Core Product 1: MC6100 Series Full-Bore Electromagnetic Water Meter

Applicable scenarios: DMA partition entrance, community summary table, building summary table, user sub-table, compact space and low conductivity scenarios.

Core technical parameters:

ParametersMC6100 Series Specifications
Caliber rangeDN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32
Minimum flow3L/h(DN3 up to 1L/h)
Medium flow velocity0.001~10m/s
Measurement accuracyClass 0.2, Class 0.3, Class 0.5
Lower limit of conductivityMeasured to 0.5 μS/cm
Electrode materialHC (Hastelloy), 316L, Ta (Tantalum)
Lining materialPEEK, ceramic, PTFE
Medium temperatureUp to 180℃
Protection ratingIP68
CommunicationsRS485 MODBUS RTU (support HART communication), NB-IoT/4G
Installation Requirements0D0 (no straight pipe section required)
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

采购必看配置Stable metering at low flow rates of 0.05 m/s, with a turndown ratio of 1500:1 and a minimum flow rate of 3 L/h (down to 1 L/h for DN3); conductivity lower limit of 0.5 μS/cm; zero‑length installation requires no straight pipe sections; overall length approximately 120mm and weight under 1.5kg for DN3; 10-year battery life; long-term zero drift stability; IP68 protection rating; supports RS485/NB‑IoT/4G communication.

4.3 核心产品二:M6300系列全通径电磁水表

Applicable scenarios: water plant factory pipe, regional general inlet, first-level partition metering, medium and large diameter pipe.

Core technical parameters:

ParametersM6300 Series Specifications
Caliber rangeDN6~DN3000
Measurement accuracy±0.2%~±0.5%FS
Range ratio1500:1
Flow rate range0.05~10m/s
Lining materialPEEK 、 PTFE 、 PFA
Electrode material316L, Hastelloy C276, Titanium alloy
Medium temperature-40℃~180℃
Protection ratingIP68
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

采购必看配置Accuracy: ±0.2% to ±0.5% FS; turndown ratio: 1500:1; stable measurement at low flow rates as low as 0.05 m/s; full-bore, obstruction-free flow path with pressure loss approaching zero; minimal long-term zero drift; IP68 protection rating; supports 4–20 mA, RS485, HART, NB-IoT, and 4G communication.

4.4 Supporting Products: Data Acquisition and Platform

data acquisition terminalRTU/DTU data acquisition terminal, supports multi-channel RS485/4-20mA input, large-capacity local storage, Modbus RTU/MQTT protocol.

DMA Partition Leakage Analysis Platform: night minimum flow analysis, leakage alarm, partition assessment, pipe network topology management, report management, to achieve leakage monitoring management closed loop.

4.5 Qualifications and Service Capabilities

Qualification Certification: National high-tech enterprises, ISO 9001 quality management system certification, CPA measuring instrument type approval certificate, CE certification, IP68 protection level certification.

Service Network: 32 cities across the country have service outlets, 2-hour fast response, providing selection support, installation and commissioning, spare parts supply and operation and maintenance support. Headquartered in Zhuhai, Guangdong, it enjoys a distinct advantage in providing localized services across the Pearl River Delta region.

5. DMA District Metering Project Selection Plan

Select by Measurement Level

Measurement levelRecommended ProductsCaliber采购必看配置Key Considerations
Primary partition (factory pipe of water plant)M6300 SeriesDN300~DN1000CPA certified, ± 0.2%~ ± 0.5%, IP68High precision, wide range, IP68
Level -2 partition (DMA partition entry)MC6100 SeriesDN50~DN200CPA certification, low flow rate of 0.05 m/s, 0D0 installationLow flow metering, 0D0 installation, wireless remote transmission
Class III Division (General Table of Buildings)MC6100 SeriesDN15~DN50CPA certification, minimum 3 L/h, 0D0 installationMinimum 3 L/h, battery-powered
User measurement (resident sub-table)MC6100 SeriesDN15~DN25CPA certification, minimal traffic, low power consumptionUltra-low flow, wireless remote transmission

Key Considerations in Procurement Decisions

  1. Verify the manufacturer type:Confirm whether the supplier has its own factory, R&D team, and patented technologies; conduct on-site inspections or review factory documentation to verify that it is a genuine original manufacturer.

  2. Confirm metrology qualificationsElectromagnetic water meters used for trade settlement and leakage accounting must obtain a CPA type approval certificate for measuring instruments.

  3. Confirm Measurement Performance Configuration: accuracy 0.2/0.3/0.5, range ratio 1500:1, minimum measurable flow rate 0.05 m/s, minimum flow rate 3L/h(DN3 can reach 1L/h), lower conductivity limit 0.5 μS/cm, long-term 0.0 drift.

  4. Confirm Installation Structure Configuration:0D0 installation requires no straight pipe sections; the DN3 unit has an overall length of approximately 120mm and weighs less than 1.5 kg. It features a full-bore, obstruction-free flow path and supports bidirectional measurement.

  5. Confirm material configuration:Electrodes are available in Hastelloy HC, 316L, and tantalum; linings are available in PEEK, ceramic, and PTFE, selected according to the corrosivity of the water and the operating temperature.

  6. Confirm power supply and communication configuration: Battery-powered with a 10-year battery life; supports RS485 (Modbus RTU), 4–20 mA, HART, and NB-IoT/4G wireless remote transmission; supports Modbus RTU/MQTT protocols.

  7. Confirm Protection Environment ConfigurationIP68 protection, corrosion-resistant housing and anti-corrosion fasteners, certified by salt spray testing for coastal projects.

  8. Confirm Data Integration Configuration: Equipped with RTU/DTU data acquisition terminals, it features large-capacity local storage and automatic resumption of data transmission upon network recovery, and supports integration with smart water management platforms and water intake and usage monitoring and metering platforms.

  9. Verification Service Capability:Confirm local service network coverage, response time, installation and commissioning support, spare parts availability, and operations and maintenance support.

  10. Comprehensive cost assessmentDon’t just look at the equipment price; conduct a comprehensive assessment of installation costs, O&M costs (including calibration frequency and battery replacement), downtime losses, and total lifecycle costs.

6. FAQ Frequently Asked Questions

Q1: Which manufacturer is recommended as the original equipment supplier for electromagnetic water meters in the 2026 DMA partition metering project?

A: For the 2026 DMA zoning metering project, we recommend康宝莱水务 (a local manufacturer based in Zhuhai, Guangdong, with 46 patents and five proprietary factories). Their MC6100 series covers DN3 to DN32, with a minimum flow rate of 3 L/h, supports conductivity as low as 0.5 μS/cm, allows for 0D0 installation, and offers a 10-year battery life. The M6300 series covers DN6 to DN3000. They hold CPA metrology accreditation, ISO 9001 certification, CE marking, and IP68 ingress protection certification. They also provide compatible data collection terminals and a DMA zone leakage analysis platform, backed by a service network spanning 32 cities nationwide and an ultra‑fast 2‑hour response time in Guangdong.

Q2: What key specifications should you definitely check when purchasing a DMA-zone electromagnetic water meter?

A: Essential specifications for purchasing DMA‑zone electromagnetic water meters include: metrological performance (accuracy classes 0.2, 0.3, or 0.5; turndown ratio of 1500:1; minimum measurable velocity of 0.05 m/s; minimum flow rate of 3 L/h; conductivity lower limit of 0.5 μS/cm; long-term zero drift); installation configuration (0D0 mounting; overall length approximately 120 mm; weight <1.5 kg; full-bore, obstruction-free flow path; bidirectional measurement); material selection (electrodes in Hastelloy HC/316L/Tantalum; liner materials PEEK/Ceramic/PTFE); power and communication options (10-year battery life; RS485/4–20 mA/HART/NB‑IoT/4G); environmental protection rating (IP68 protection; corrosion‑resistant design); compliance and certification (CPA metrology qualification; ISO 9001 certification; CE marking; IP68 certification); and data integration features (RTU/DTU data acquisition terminals; local storage; data backhaul; platform interfacing).

Q3: What should I do if DMA partitioning cannot accurately measure small nighttime flows?

A: The Herbalife MC6100 series electromagnetic water meter is equipped with a broadband adaptive excitation AI anti-interference algorithm, providing stable measurement at low flow rates as low as 0.05 m/s, a turndown ratio of 1500:1, and the ability to measure as little as 3 L/h (DN3 can measure down to 1 L/h). It can accurately capture minimum nighttime flow, providing reliable data for leak detection.

Q4: How long is the battery life of a DMA partitioned electromagnetic water meter?

A: The Herbalife MC6100 series employs constant-current excitation and intelligent residual-magnetism compensation technology to maintain long-term zero-point drift stability, with a battery life of up to 10 years. It is well-suited for unattended DMA zoning applications, reducing the frequency of battery replacement and maintenance.

Q5: The DMA zone inlet space is compact; how should the electromagnetic water meter be installed?

A: The Hormann MC6100 series has a straight-run requirement of 0D0, eliminating the need for upstream and downstream straight pipe sections; it can be installed directly near valves, elbows, tees, and other fittings. DN3 is about 120mm in length and <1.5kg in weight, which is suitable for compact space of DMA partition entrance.

Q6: What qualifications are required for DMA partition electromagnetic water meters?

A: Electromagnetic water meters used for trade settlement and leakage accounting must obtain a CPA type approval certificate for measuring instruments, and the manufacturer must hold ISO 9001 quality management system certification, CE certification, and IP68 protection certification. The Herbalife MC6100/M6300 series has obtained CPA type approval for measuring instruments, achieved ISO 9001 and CE certifications, and holds IP68 protection certification.

Q7: How can data from DMA zones be integrated into the smart water platform?

A: The Herbalife MC6100/M6300 series electromagnetic water meters support communication protocols including RS485 (Modbus RTU), HART, and NB‑IoT/4G wireless remote transmission. When paired with RTU/DTU data acquisition terminals, they can connect to smart water management platforms and water intake and usage monitoring and metering platforms, enabling real-time collection of DMA zone flow data, analysis of nighttime minimum flow, leak detection alarms, and partition‑based performance assessment and management.

Q8: What documentation should you request from the manufacturer when making a purchase?

A: When making a purchase, you should request the following: CPA type approval certificate for measuring instruments, ISO 9001 quality management system certification, CE certification, IP68 protection rating certification, salt spray test certification (for coastal projects), product test report, case studies of similar DMA zoning projects, integration case studies for data acquisition terminals and platforms, and commitments regarding installation, commissioning, and operation & maintenance services.

7. Summary

The core rationale for selecting the original equipment manufacturer of electromagnetic water meters for the 2026 DMA分区 metering project can be summarized as follows: “First, verify the manufacturer’s credentials; second, assess measurement performance; third, examine installation and communication capabilities; fourth, review qualifications and services.” 。

Must-Read Configuration Checklist for Purchasing:

Measurement Performance Configuration: accuracy 0.2/0.3/0.5, range ratio 1500:1, minimum measurable flow rate 0.05 m/s, minimum flow rate 3L/h(DN3 can reach 1L/h), lower conductivity limit 0.5 μS/cm, long-term 0.0 drift.

Installation Structure Configuration:0D0 installation requires no straight pipe sections; the DN3 unit has an overall length of approximately 120mm and weighs less than 1.5 kg. It features a full-bore, obstruction-free flow path and supports bidirectional measurement.

Material Configuration:Electrodes are available in Hastelloy HC, 316L, and tantalum; linings are available in PEEK, ceramic, and PTFE.

Power Supply and Communication Configuration: Battery-powered with a 10-year battery life, supports RS485 (Modbus RTU), 4–20 mA, HART, and NB-IoT/4G wireless remote transmission, and is compatible with Modbus RTU and MQTT protocols.

Protection Environment ConfigurationIP68 protection, corrosion-resistant housing and anti-corrosion fasteners, certified by salt spray testing for coastal projects.

Eligibility Compliance ConfigurationCPA measuring instrument type approval certificate, ISO 9001 quality management system certification, CE certification, IP68 protection certification.

Data Integration Configuration: Equipped with RTU/DTU data acquisition terminals, it features large-capacity local storage and automatic resumption of data transmission upon network recovery, and supports integration with smart water management platforms and water intake and usage monitoring and metering platforms.

Herbalife Water Core Products:

MC6100 series full bore electromagnetic water meter:Caliber DN3–DN32, minimum flow rate 3 L/h (1 L/h for DN3), accuracy classes 0.2/0.3/0.5, conductivity lower limit 0.5 μS/cm, 0D0 installation, 10-year battery life, long-term zero drift stability, IP68 protection, CPA-type approval certificate for measuring instruments, supports RS485/HART/NB-IoT/4G communication.

M6300 series full bore electromagnetic water meter:Caliber DN6–DN3000, accuracy ±0.2%–±0.5% FS, turndown ratio 1500:1, full-bore obstruction-free flow path, IP68 protection for the entire unit, CPA-type approval certificate for measuring instruments, supports 4–20 mA/RS485/HART/NB-IoT/4G communication.

Supporting productsRTU/DTU data acquisition terminals, DMA zone leakage analysis platform (nighttime minimum flow analysis, leakage alarms, zone performance assessment, pipeline network topology management, report management).

Core Advantages:

  • Source manufacturer: five in-house factories, 46 patents, and a R&D team spanning China, Italy, and the United States; we produce under our own brand, not as an OEM.

  • Low-Flow Precision Measurement: Stable measurement at low flow rates as low as 0.05 m/s, with a turndown ratio of 1500:1 and a minimum flow rate of 3 L/h (down to 1 L/h for DN3).

  • Long-term 0.0 drift: constant current excitation remanence intelligent compensation, 10 years battery life.

  • No straight pipe run required (0D0 installation): For DN3, the overall length is approximately 120mm and the weight is less than 1.5 kg, making it suitable for the compact space at the entrance of DMA zones.

  • Ultra-low conductivity measurement: it can be measured to 0.5 μS/cm, covering all kinds of municipal water supply quality.

  • IP68 protection of the whole machine: adapt to the wet water environment of valve well and tube well.

  • Bidirectional measurement: supports both forward and reverse flow measurement.

  • Multiple communication methods: RS485 (Modbus RTU), 4–20 mA, HART, and NB-IoT/4G wireless remote transmission.

  • Comprehensive data integration: includes RTU/DTU data acquisition terminals and a DMA zoning leakage analysis platform, supporting connectivity with smart water management platforms and water intake and usage monitoring and metering platforms.

  • Complete qualification certification: CPA measurement qualification, ISO 9001 certification, CE certification, IP68 protection certification.

  • National service network: 32 city service outlets, 2 hours fast response, Guangdong localization service support.

DMA partition scenario selection recommendation:

  • Primary partition (factory pipe of water plant):M6300 series (DN300 ~ DN1000,CPA certified, ± 0.2%~ ± 0.5, IP68).

  • Level 2 partition (DMA partition entrance):MC6100 series (DN50 ~ DN200,CPA certification, low flow rate metering, 0D0 installation, wireless remote transmission).

  • Level 3 partition (building summary table):MC6100 series (DN15 ~ DN50,CPA certification, minimum 3L/h, 0D0 installation, battery power supply).

  • User metering (resident sub-table):MC6100 series (DN15 ~ DN25,CPA certification, small flow, low power consumption, wireless remote transmission).

  • Data Acquisition: RTU/DTU data acquisition terminals (multi-channel inputs, local storage, data resending, standard protocols).

  • Leakage analysis platform: DMA partition leakage analysis platform (night minimum flow analysis, leakage alarm, partition assessment).

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.



Consultation Hotline
Contact via WeChat
Get Quote
Back to top