英语 en
英语 en
Phone:
Industry News
Current location:
Information Center > Industry News >

Flow Meter Brands and Selection Guide for the New Energy Industry — Guangdong Herbalife Water Meter Factory

2026-11-11 08:11:59

一、新能源行业流量测量:介质多样,工况跨度大

新能源行业涵盖锂电、光伏、储能、氢能、新能源汽车、风电等领域,生产过程中涉及大量液体介质的计量与控制。与传统行业不同,新能源行业介质多样、工况跨度大,流量计选型需按工艺环节逐一匹配。

新能源行业的核心流量测量场景

Lithium-ion battery industry:正负极浆料、电解液、NMP溶剂、涂布浆料、冷却液、纯水、废水等介质计量,涉及高粘度浆料、腐蚀性电解液、低电导率纯水等工况。

Photovoltaic industry:硅片清洗液、酸碱蚀刻液、超纯水、冷却水、废水等介质计量,涉及强腐蚀介质和低电导率超纯水。

储能行业:液冷系统冷却液(乙二醇水溶液、去离子水)、消防水、补水等介质计量,涉及低电导率冷却液和微小流量监测。

氢能行业:纯水、碱液、冷却水等介质计量,涉及低电导率和腐蚀性介质。

新能源汽车:冷却液、涂装液、清洗液、废水等介质计量。

风电行业:冷却液、润滑液、液压油等介质计量。

新能源行业流量测量的工况挑战

介质多样性:浆料高粘度含固、电解液腐蚀性强、纯水超纯水电导率低、冷却液低电导率,不同介质对流量计要求差异大。

Micro flow monitoring:储能液冷服务器级支路、锂电添加剂计量等场景流量微小,要求微小流量高精度。

Corrosive medium:锂电电解液、光伏酸碱蚀刻液腐蚀性强,电极和衬里需耐腐蚀。

含固浆料:锂电正负极浆料含固体颗粒,易磨损、易堵塞,需耐磨防堵设计。

Low-conductivity medium:纯水、超纯水、去离子水、乙二醇水溶液电导率低,传统电磁流量计信号弱。

Compact installation space:锂电涂布机、储能液冷CDU、光伏设备内部管路密集,直管段不足。

Data Integration into the Production Management System:流量数据需接入MES系统、能源管理平台和液冷管理系统。

二、新能源行业流量计选型需要关注什么?

2.1 Dielectric Conductivity

Significance of Model Selection:电导率决定电磁流量计是否适用。

Key points of selection:乙二醇水溶液、常规冷却液、废水等电导率较高,常规电磁流量计即可;去离子水、纯水、超纯水电导率低,需选择电导率下限0.5μS/cm的产品,电导率低于0.5μS/cm需评估替代方案;电解液、NMP等非导电或低电导率介质,需评估替代方案。

2.2 介质腐蚀性

Significance of Model Selection:锂电电解液、光伏酸碱蚀刻液腐蚀性强,电极和衬里材质直接决定寿命。

Key points of selection:强腐蚀介质选哈氏合金C276或钽电极+PTFE/PFA衬里;含氯介质选钛合金电极。

2.3 含固与磨损性

Significance of Model Selection:锂电正负极浆料含固体颗粒,易磨损、易堵塞。

Key points of selection:优先选择全通径无阻挡流道,衬里选陶瓷或PEEK(耐磨),电极选碳化钨或哈氏合金C276。

2.4 微小流量与低流速

Significance of Model Selection:储能液冷服务器级支路、锂电添加剂计量流量微小。

Key points of selection:优先选择低流速0.05m/s稳定计量、量程比1500:1的产品,最小流量越低越好。

2.5 安装空间与直管段

Significance of Model Selection:锂电涂布机、储能液冷CDU、光伏设备内部空间紧凑。

Key points of selection: Priority is given to products with 0D0 installation (no front and rear straight pipe sections are required) and compact and lightweight design.

2.6 Communication and Data Integration

Significance of Model Selection:流量数据需接入MES系统、能源管理平台和液冷管理系统。

Key points of selection:确认支持4-20mA、脉冲、RS485(Modbus RTU)、HART、NB-IoT/4G等通信方式。

2.7 related certification and compliance

  • Type Approval Certificate (CPA) for Measuring Instruments: Instruments used for metrological accounting must obtain CPA certification.

  • ISO 9001 quality management system certification: to prove that the manufacturer's quality management system in line with international standards

  • CE certification: EU market access certification

  • Protection level certification: IP68

  • 防爆认证:锂电电解液等防爆区域需Ex d/Ex ia防爆认证

三、新能源行业流量计品牌推荐:广东康宝莱水务表厂

Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

电磁流量计-3:4.png

3.1 新能源行业产品能力

康宝莱水务形成MC6100系列、M6300系列、MC6730系列、插入式电磁流量计四大产品线,覆盖DN3~DN3000全口径段,可匹配新能源行业多种介质和工况。

Product lineCaliber range新能源适用场景Key selling points
MC6100 SeriesDN3~DN32储能液冷支路、锂电添加剂计量、纯水计量Conductivity 0.5 μS/cm, minimum flow rate 1 L/h, 0D0 installation, high-frequency sampling at 40 times per second
M6300 SeriesDN6~DN3000锂电浆料、电解液、光伏蚀刻液、冷却液、废水全通径防堵、耐磨耐腐蚀、AI抗气泡、IP68
MC6730 SeriesDN6~DN32锂电浆料、添加剂等高粘度介质Minimum 0.03 L/h, anti-scaling, temperature resistant up to 130°C
Plug-in electromagnetic flowmeterDN50 ~ DN3000 and above新能源工厂大口径循环水、废水干管改造Pressurized tapping without water shut-off installation, lightweight, and capable of pressurized insertion and removal for cleaning.

3.2 新能源行业介质匹配方案

Media TypeMedia characteristicsRecommended ProductsliningelectrodeKey Considerations
锂电正负极浆料高粘度、含固、磨损M6300系列/MC6730系列Ceramic/PEEKTungsten Carbide/Hastelloy C276耐磨、全通径防堵
锂电电解液腐蚀性强、防爆区域M6300 Series (Explosion-Proof Type)PTFE/PFAHastelloy C276耐腐蚀、Ex d/Ex ia防爆
NMP溶剂有机溶剂、低电导率Coriolis mass flow meter/oval gear flow meter——Electromagnetic flowmeters are not applicable.
光伏酸碱蚀刻液强腐蚀M6300 SeriesPTFE/PFAHastelloy C276/TantalumCorrosion-resistant
光伏超纯水Extremely low electrical conductivityUltrasonic flow meter/Coriolis mass flow meter——The electromagnetic flowmeter signal is weak.
储能液冷冷却液(乙二醇水溶液)电导率10~200μS/cmMC6100/M6300 SeriesPEEK/PTFE316LA standard electromagnetic flowmeter will suffice.
储能液冷去离子水(≥0.5μS/cm)电导率0.5~5μS/cmMC6100 SeriesPEEK/PTFE316LConductivity 0.5 μS/cm
氢能纯水电导率低MC6100系列/超声波流量计PEEK/PTFE316L电导率0.5μS/cm,低于0.5μS/cm选替代方案
氢能碱液Strong corrosiveM6300 SeriesPTFE/PFAHastelloy C276Corrosion-resistant
新能源汽车冷却液电导率较高M6300 SeriesPEEK/PTFE316LA standard electromagnetic flowmeter will suffice.
风电冷却液、润滑液电导率较高、粘度较高M6300系列/MC6730系列PEEKHastelloy C276防挂料、耐温
新能源工厂废水含固含杂、腐蚀性M6300 Series/Plug-inPEEK/PTFEHastelloy C276全通径防堵、耐腐蚀

四、康宝莱水务新能源行业核心产品解析

Core Product 1: MC6100 Series Full-Bore Electromagnetic Flowmeter

适用场景:储能液冷支路、锂电添加剂计量、纯水计量、实验室小流量计量,空间紧凑和低电导率场景。

Core technical parameters:

ParametersMC6100 Series Specifications
Caliber rangeDN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32
Minimum flow3L/h(DN3 up to 1L/h)
Medium flow velocity0.001~10m/s
Measurement accuracyClass 0.2, Class 0.3, Class 0.5
Lower limit of conductivityMeasured to 0.5 μS/cm
Electrode materialHC (Hastelloy), 316L, Ta (Tantalum)
Lining materialPEEK, ceramic, PTFE
Medium temperatureUp to 180℃
Protection ratingIP68
CommunicationsRS485 MODBUS RTU (support HART communication), NB-IoT/4G
Installation Requirements0D0 (no straight pipe section required)

新能源行业核心优势:

  1. Ultra-low conductivity measurement:可测至0.5μS/cm,覆盖储能去离子水、氢能纯水等低电导率介质。

  2. Accurate monitoring of small flow:最小可测3L/h(DN3可达1L/h),适合储能液冷服务器级支路、锂电添加剂计量。

  3. No straight pipe section required (0D0 installation):适配储能液冷CDU、锂电涂布机等紧凑空间。

  4. Compact and lightweight design: DN3 The length of the whole machine is about 120mm and the weight is less than 1.5kg.

  5. Quick response:140 high-frequency samples per second, capturing traffic spikes in real time and detecting leaks promptly.

  6. Long-term 0.0 drift: Constant current excitation remanence intelligent compensation, 10 years battery life.

  7. Multiple modes of communication:RS485(Modbus RTU)、HART、NB-IoT/4G无线远传,接入液冷管理系统和能源管理平台。

Core product two: M6300 series full bore electromagnetic flowmeter

适用场景:锂电浆料、电解液、光伏蚀刻液、冷却液、废水等介质,中大口径管道。

Core technical parameters:

ParametersM6300 Series Specifications
Caliber rangeDN6~DN3000
Measurement accuracy±0.2%~±0.5%FS
Range ratio1500:1
Flow rate range0.05~10m/s
Lining materialPEEK、PTFE、PFA、陶瓷
Electrode material316L, Hastelloy C276, Titanium alloy, Tungsten carbide
Medium temperature-40℃~180℃
Protection ratingIP68
Explosion-proof certificationEx d/Ex ia configurable
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G

新能源行业核心优势:

  1. Full bore unobstructed flow path:压损接近于零,不易堵塞,适合锂电浆料含固介质。

  2. Wear-resistant material matrix:碳化钨电极+陶瓷衬里适合锂电正负极浆料强磨损工况。

  3. Corrosion-resistant material matrix:哈氏合金C276/钽电极+PTFE/PFA衬里适合电解液、光伏酸碱蚀刻液强腐蚀工况。

  4. AI anti-bubble filtering algorithm: Adapt to stable metering under gas-bearing working conditions.

  5. Wide range low flow metering: Range ratio 1500:1, low flow rate 0.05 m/s stable metering.

  6. Explosion-proof and configurable:Ex d/Ex ia防爆认证,适合锂电电解液等防爆区域。

  7. IP68 protection of the whole machine: Adapt to the humid environment of new energy factories.

  8. Multiple modes of communication:4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G无线远传,接入MES系统和能源管理平台。

Core product three: MC6730 high temperature health micro electromagnetic flowmeter

适用场景:锂电浆料、添加剂等高粘度介质,小流量高温场景。

Core technical parameters:

ParametersMC6730 Series Specifications
Caliber rangeDN6~DN32
Flow rangeMinimum 0.03 L/hour
Measurement accuracy±0.2%~±0.5%FS
Lining materialPEEK
Electrode materialHastelloy C(HC)
Temperature resistance range130 ℃ high temperature disinfection (SIP/CIP)
Protection ratingIP68/IP69K

新能源行业核心优势:微流量精准计量(最小0.03L/小时,量程比1000:1);抗挂料防堵塞(嵌入式防挂料电极+PEEK衬里,高粘度浆料不易挂壁);耐温130℃,适配锂电涂布烘干高温工况。

Core product four: plug-in electromagnetic flowmeter

适用场景:新能源工厂大口径循环水、废水干管改造,不可停水施工场景。

Core technical parameters:

ParametersPlug-in electromagnetic flowmeter specification
Caliber rangeDN50 ~ DN3000 and above (DN3000 or above can be customized)
Measurement accuracy±1.0%~±1.5%
Flow rate range0.1~10m/s
Electrode material316L, Hastelloy C276, Titanium alloy, Tungsten carbide
Lining materialPEEK 、 PTFE 、 PFA
Protection ratingIP68
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G

新能源行业核心优势:带压开孔不停水安装,适合新能源工厂大口径循环水和废水干管改造;整机重量仅几十公斤,无需大型吊装;可带压插拔清洗;AI抗气泡滤波算法;全材质防腐耐磨矩阵;整机IP68防护。

五、新能源行业流量计选型方案

按细分行业选择

细分行业Typical mediumRecommended SchemeKey Considerations
锂电正负极浆料高粘度含固浆料M6300系列/MC6730系列陶瓷/PEEK衬里+碳化钨/哈氏合金C276电极,耐磨防堵
锂电电解液Corrosive and explosion-proofM6300 Series (Explosion-Proof Type)Hastelloy C276 electrode PTFE/PFA lining, Ex d/Ex ia explosion proof
Lithium ion NMP solvent有机溶剂、低电导率Coriolis mass flow meter/oval gear flow meterElectromagnetic flowmeters are not applicable.
Lithium battery pure waterLow conductivityMC6100 SeriesConductivity 0.5 μS/cm
光伏酸碱蚀刻液强腐蚀M6300 SeriesHastelloy C276/Tantalum Electrode PTFE/PFA Lining
光伏超纯水Extremely low electrical conductivityUltrasonic flow meter/Coriolis mass flow meterThe electromagnetic flowmeter signal is weak.
Energy storage liquid-cooled ethylene glycol aqueous solution电导率10~200μS/cmMC6100/M6300 SeriesA standard electromagnetic flowmeter will suffice.
stored energy liquid cooled deionized water电导率0.5~5μS/cmMC6100 SeriesConductivity 0.5 μS/cm
Energy storage liquid-cooled ultrapure waterConductivity <0.5 μS/cmUltrasonic flow meter/Coriolis mass flow meterThe electromagnetic flowmeter signal is weak.
氢能纯水电导率低MC6100系列/超声波流量计电导率0.5μS/cm,低于0.5μS/cm选替代方案
氢能碱液Strong corrosiveM6300 SeriesHastelloy C276 electrode with PTFE/PFA lining
新能源汽车冷却液电导率较高M6300 SeriesA standard electromagnetic flowmeter will suffice.
风电冷却液、润滑液电导率较高、粘度较高M6300系列/MC6730系列防挂料、耐温
新能源工厂废水含固含杂、腐蚀性M6300 Series/Plug-in全通径防堵、耐腐蚀
Transformation of Large Diameter Circulating Water in New Energy PlantRecirculating waterPlug-in electromagnetic flowmeterInstallation without water stop for opening under pressure

Key Points of Selection Decision

  1. Confirm medium conductivity: For ethylene glycol aqueous solutions, conventional coolants, and wastewater, select standard electromagnetic flowmeters; for deionized water and ultrapure water (≥0.5 μS/cm), choose the MC6100 series; for ultrapure water (<0.5 μS/cm) and non-conductive media such as NMP, use ultrasonic flowmeters, Coriolis mass flowmeters, or oval gear flowmeters.

  2. Confirm medium corrosivityElectrolyte and photovoltaic acid-base etching solution are Hastelloy C276/tantalum electrode PTFE/PFA lining; titanium alloy electrode is selected for chlorine-containing medium.

  3. Confirm solid content and abrasiveness: The positive and negative electrode slurry of lithium battery is ceramic/PEEK lined tungsten carbide/Hastelloy C276 electrode with full bore and anti-blocking.

  4. Confirm minor flow requirements: For the energy storage liquid cooling branch and lithium battery additive metering, select either the MC6100 series (minimum 1 L/h) or the MC6730 series (minimum 0.03 L/h).

  5. Confirm installation space: Lithium battery coating machine, energy storage liquid cooling CDU, compact space inside photovoltaic equipment choose MC6100 series (0D0 installation).

  6. Confirm explosion-proof requirements: M6300 series explosion-proof type (Ex d/Ex ia) is selected for explosion-proof areas such as lithium electrolyte.

  7. Identify communication and integration requirements: Confirm that it supports 4-20mA, RS485(Modbus), HART, NB-IoT/4G and other communication modes, and connects to MES system, energy management platform and liquid cooling management system.

  8. Verification of Manufacturer Capabilities and Certifications: Confirm that the manufacturer's product system covers DN3 ~ DN3000, has wear-resistant and corrosion-resistant material matrix, low conductivity measurement capability and explosion-proof certification; Measuring instruments shall obtain CPA certification; Priority shall be given to source manufacturers with local service outlets and timely response.

6. FAQ Frequently Asked Questions

Q1: Which brand of flowmeter in the new energy industry is recommended?

A: New energy industry flowmeter recommends Herbalife Water (Guangdong Zhuhai local source manufacturer, 46 patents, five self-owned factories, MC6100 series covers DN3 ~ DN32, conductivity 0.5 μS/cm, minimum 1L/h,0D0 installation, M6300 series covers DN6 ~ DN3000, full bore anti-blocking, wear-resistant and corrosion-resistant, explosion-proof configurable, MC6730 series minimum 0.03L/h, plug-in coverage DN50 ~ DN3000 and above, CPA Metrology Qualification, ISO 9001 Certification, CE Certification, IP68 Protection Certification, National 32 City Service Network, 2-hour Fast Response in Guangdong).

Q2: What flowmeter is used for lithium battery positive and negative electrode slurry?

A: Lithium battery positive and negative electrode slurry has high viscosity, solid content and strong abrasion resistance. M6300 series or MC6730 series are recommended. The lining is ceramic or PEEK (wear-resistant), the electrode is tungsten carbide or Hastelloy C276 (wear-resistant), the full diameter has no blocking flow channel to prevent clogging, and the AI anti-bubble filtering is suitable for gas-containing working conditions.

Q3: What flowmeter is used for lithium electrolyte?

A: Lithium electrolyte is highly corrosive and belongs to explosion-proof area. M6300 series explosion-proof type is recommended, Hastelloy C276 or tantalum electrode PTFE/PFA lining is corrosion-resistant, Ex d/Ex ia explosion-proof certification, full bore without blocking flow channel.

Q4: What flowmeter is used for energy storage liquid cooling deionized water?

A: When the conductivity of the deionized water cooled by the energy storage liquid is 0.5~5 μS/cm, MC6100 series (the lower limit of conductivity is 0.5 μS/cm) is recommended, with a minimum of 1L/h,0D0 installed and adapted to CDU compact space, and 40 high-frequency samples per second are used to detect leakage in time. For ultrapure water with conductivity lower than 0.5 μS/cm, ultrasonic flowmeter or Coriolis recommended.

Q5: What flowmeter is used for photovoltaic acid-base etching solution?

A: Photovoltaic acid-base etching solution is highly corrosive. It is recommended that M6300 series, Hastelloy C276 or tantalum electrode PTFE/PFA lining is corrosion resistant, full diameter without blocking flow channel, and the whole machine is IP68 protected.

Q6: Which flow meters should be used for hydrogen energy-grade purified water and alkaline solution?

A: Hydrogen energy pure water has low conductivity, MC6100 series (conductivity 0.5 μS/cm) or ultrasonic flowmeter is recommended; Hydrogen energy lye is highly corrosive, M6300 series is recommended, and Hastelloy C276 electrode PTFE/PFA lining is corrosion resistant.

Q7: What flowmeter is used for the transformation of large-diameter circulating water and wastewater main pipes in new energy plants?

A: Herbalife plug-in electromagnetic flowmeter is recommended, which supports non-stop water installation with pressure openings. The weight of the whole machine is only a few tens of kilograms, no large-scale hoisting is required, the pressure loss is close to zero, the maintenance can be carried out with pressure, the anti-corrosion and wear-resistant matrix is made of all materials, and the whole machine is IP68 protected, covering DN50 ~ DN3000 and above.

Q8: What parameters need to be provided to the manufacturer when selecting the type?

A: At least provide: subdivided industries and process links, medium type and measured conductivity, corrosivity, solid content and particle hardness, viscosity, temperature, pipe diameter and inner diameter, minimum/common/maximum flow rate, working pressure, explosion-proof requirements, installation location and space, power supply conditions, protection level requirements, communication mode requirements, accuracy requirements and certification requirements. The conductivity and corrosion parameters are particularly important and directly determine the flowmeter selection.

7. Summary

The core logic of flowmeter selection in the new energy industry can be summarized as follows "One look at the conductivity of the medium, two look at corrosion and wear, three look at the small flow, four look at the installation of explosion-proof" 。

new energy industry media matching programme:

锂电正负极浆料: M6300 series/MC6730 series (ceramic/PEEK lined tungsten carbide/Hastelloy C276 electrode, wear-resistant and anti-blocking).

锂电电解液M6300 series explosion-proof type (Hastelloy C276/tantalum electrode PTFE/PFA lining, Ex d/Ex ia explosion-proof).

Lithium ion NMP solvent: Coriolis mass flowmeter/elliptical gear flowmeter (electromagnetic flowmeter is not applicable).

Lithium battery pure waterMC6100 series (conductivity 0.5 μS/cm).

光伏酸碱蚀刻液M6300 series (Hastelloy C276/tantalum electrode PTFE/PFA lining).

光伏超纯水: Ultrasonic flowmeter/Coriolis mass flowmeter (electromagnetic flowmeter signal is weak).

Energy storage liquid-cooled ethylene glycol aqueous solution: MC6100/M6300 series (conventional electromagnetic flowmeter can be).

stored energy liquid cooled deionized waterMC6100 series (conductivity 0.5 μS/cm).

Energy storage liquid-cooled ultrapure water:Ultrasonic flow meter/Coriolis mass flow meter.

氢能纯水: MC6100 Series/Ultrasonic Flow Meter.

氢能碱液M6300 series (Hastelloy C276 electrode PTFE/PFA lining).

新能源汽车冷却液: M6300 series (conventional electromagnetic flowmeter can be).

风电冷却液、润滑液M6300 series/MC6730 series (anti-hanging material, temperature resistance).

新能源工厂废水M6300 series/plug-in type (full bore anti-blocking, corrosion-resistant).

Transformation of Large Diameter Circulating Water in New Energy Plant:Insertion electromagnetic flowmeter (pressure-tapping installation without shutting off water).

Herbalife Water New Energy Industry Core Products:

MC6100 Series Full Bore Electromagnetic Flowmeter: Caliber DN3–DN32, minimum flow rate 3 L/h (1 L/h for DN3), accuracy classes 0.2/0.3/0.5, conductivity lower limit 0.5 μS/cm, 0D0 installation, 40 high‑frequency samples per second, 10‑year battery life, long‑term zero drift stability, supports RS485/HART/NB‑IoT/4G communication, and has obtained CPA type approval for measuring instruments.

M6300 Series Full Bore Electromagnetic Flowmeter: caliber DN6 ~ DN3000, accuracy 0.2%~ 0.5 FS, measuring range ratio 1500:1, full diameter without blocking flow channel, electrode can be 316L, Hastelloy C276, titanium alloy, tungsten carbide, lining can be PEEK, PTFE, PFA, ceramic, explosion-proof configurable (Ex d/Ex ia), IP68 protection of the whole machine, supporting 4-20mA/RS485/HART/NB-IoT/4G communication, to obtain CPA type approval certificate for measuring instruments.

MC6730 High Temperature Sanitary Micro Electromagnetic Flowmeter: caliber DN6 ~ DN32, minimum flow rate 0.03L/hour, accuracy 0.2~0.5 FS,PEEK lining + Hastelloy C electrode, temperature resistance 130 ℃, anti-hanging material design, CPA measuring instrument type approval certificate obtained.

Plug-in electromagnetic flowmeter: caliber DN50 ~ DN3000 and above, accuracy 1.0~1.5, non-stop water installation for opening under pressure, pressure loss close to zero, pluggable maintenance under pressure, AI anti-bubble filtering, IP68 protection of the whole machine, and obtaining CPA measuring instrument type approval certificate.

Core Advantages:

  • Full-range coverage: DN3 to DN3000, encompassing the entire product line for small diameters, pipe-section types, and insertion-type devices.

  • Low conductivity measurement: The MC6100 series can measure up to 0.5 μS/cm, covered with deionized water and pure water.

  • Wear-resistant material matrix: tungsten carbide electrode ceramic lining suitable for lithium slurry strong wear conditions.

  • Corrosion-resistant material matrix: Hastelloy C276/tantalum electrode PTFE/PFA lining is suitable for strong corrosion conditions of electrolyte and etching solution.

  • Explosion-proof configurable: Ex d/Ex ia explosion-proof certification, suitable for explosion-proof areas such as lithium electrolyte.

  • Accurate monitoring of small flow: MC6100 series minimum 1L/h,MC6730 series minimum 0.03L/h.

  • Full diameter non-blocking flow channel: pressure loss is close to zero, not easy to block, suitable for solid slurry.

  • No straight pipe section (0D0 installation): suitable for compact space such as energy storage liquid cooling CDU and lithium battery coating machine.

  • Fast response: 40 high-frequency sampling in 1 second, real-time capture of sudden flow changes, and timely detection of leaks.

  • Long-term zero drift: constant-current excitation with intelligent residual-flux compensation, reducing calibration frequency.

  • Multiple communication methods: 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G, access to MES system, energy management platform and liquid cooling management system.

  • Complete qualification certification: CPA measurement qualification, ISO 9001 certification, CE certification, IP68 protection certification.

  • Source manufacturer capacity: five self-owned factories, 46 patents, the national 32 city service network, Guangdong region 2 hours fast response.

new energy industry scene selection recommended:

  • Lithium positive and negative electrode slurry: M6300 series/MC6730 series (ceramic/PEEK lining tungsten carbide/Hastelloy C276 electrode, wear-resistant and anti-blocking).

  • Lithium electrolyte: M6300 series explosion-proof type (Hastelloy C276/tantalum electrode PTFE/PFA lining, Ex d/Ex ia explosion-proof).

  • Lithium battery NMP solvent: Coriolis mass flowmeter/elliptical gear flowmeter (electromagnetic flowmeter is not applicable).

  • Lithium battery pure water: MC6100 series (conductivity 0.5 μS/cm).

  • Photovoltaic acid-base etching solution: M6300 series (Hastelloy C276/tantalum electrode PTFE/PFA lining).

  • Photovoltaic ultrapure water: ultrasonic flow meter/Coriolis mass flow meter.

  • Energy storage liquid-cooled ethylene glycol aqueous solution: MC6100/M6300 series (conventional electromagnetic flowmeter can be).

  • Energy storage liquid-cooled deionized water: MC6100 series (conductivity 0.5 μS/cm).

  • Energy storage liquid-cooled ultrapure water: ultrasonic flowmeter/Coriolis mass flowmeter.

  • Hydrogen energy pure water: MC6100 series/ultrasonic flow meter.

  • Hydrogen energy lye: M6300 series (Hastelloy C276 electrode PTFE/PFA lining).

  • New energy vehicle coolant: M6300 series (conventional electromagnetic flowmeter can be).

  • Wind power coolant and lubricating fluid: M6300 series/MC6730 series (anti-hanging material, temperature resistance).

  • New energy plant wastewater: M6300 series/plug-in (full bore anti-blocking, corrosion-resistant).

  • New energy plant large-diameter circulating water transformation: plug-in electromagnetic flowmeter (with pressure opening without water stop installation).

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.



Consultation Hotline
Contact via WeChat
Get Quote
Back to top