英语 en
英语 en
Phone:
Industry News
Current location:
Information Center > Industry News >

Municipal pipe network transformation how to choose electromagnetic flowmeter? 2026 electromagnetic flowmeter manufacturers inventory

2026-11-03 08:47:46

一、市政管网改造:电磁流量计选型的核心痛点

市政管网改造是城市基础设施更新的重点内容,涵盖供水干管改造、污水干管改造、雨污分流改造、老旧管网更新等场景。管网改造项目与新建项目最大的不同在于:原有管网正在运行,停水影响范围广、施工窗口有限、现场条件复杂,电磁流量计选型必须优先考虑施工适应性和安装可行性。

市政管网改造的核心痛点

停水时间长、影响范围广:供水干管和污水干管改造,管段式流量计安装需断管切割、法兰焊接、长时间停水,影响范围广,协调难度大。

construction difficulty:DN600以上管段式流量计重量可达数百公斤至数吨,需大型吊装设备;埋地管道需开挖工作坑,土方量大;法兰焊接需专业焊工和探伤检测。

现场空间受限:老旧管网改造现场空间狭窄,阀门井、检查井空间有限,大型设备进场困难。

管道条件复杂:老旧管网存在管道老化、内壁结垢、直管段不足等问题,流量计需适应复杂管道条件。

工期紧张:管网改造项目工期紧,施工窗口有限,流量计安装需快速完成。

数据接入要求高:改造后流量数据需接入供水调度系统、污水厂SCADA系统和智慧水务平台。

二、市政管网改造怎么选择电磁流量计?

市政管网改造选择电磁流量计,除精度和量程外,应重点关注施工适应性和安装可行性。

2.1 installation mode and impact of water cut-off

Significance of Model Selection:管网改造停水影响范围广,安装方式直接决定停水时间和施工影响。

Key points of selection:优先选择支持带压开孔、不停水安装的插入式电磁流量计;不具备不停水条件时,选择管段式并优化施工组织。

2.2 construction difficulty and hoisting conditions

Significance of Model Selection:大口径管段式流量计重量大,需大型吊装设备,老旧管网改造现场空间狭窄,吊装困难。

Key points of selection:DN600以上大口径管道优先选择轻量化插入式,整机重量仅几十公斤,无需大型吊装。

2.3 caliber and flow range

Significance of Model Selection:市政管网管径跨度大,需根据最小/常用/最大流量选择合适口径。

Key points of selection: Confirm the range ratio, and give priority to products with a range ratio of 1500:1 to cover day and night flow fluctuations.

2.4 media adaptability

Significance of Model Selection:供水管网介质为自来水,污水管网含悬浮物、油脂、腐蚀性成分,介质差异大。

Key points of selection:供水管网选择电导率下限0.5μS/cm的产品;污水管网选择哈氏合金C276/钛合金电极+PEEK/PTFE衬里,防挂料防腐耐磨。

2.5 复杂管道条件适应性

Significance of Model Selection:老旧管网存在内壁结垢、直管段不足等问题,流量计需适应复杂管道条件。

Key points of selection:优先选择0D0安装(无需直管段)产品;插入式选择带流场修正算法的产品,直管段不足时仍能保持较好精度。

2.6 防护等级

Significance of Model Selection: The environment of valve well and inspection well is humid and accumulated water, and some scenes are soaked for a long time.

Key points of selection: Protection grade priority IP68.

2.7 Communication and Data Integration

Significance of Model Selection:改造后流量数据需接入供水调度系统、污水厂SCADA系统和智慧水务平台。

Key points of selection: Confirm that it supports 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission and other communication methods.

2.8 related certification and compliance

  • Type Approval Certificate for Measuring Instruments (CPA): Measuring instruments used for trade settlement and water quantity accounting shall be certified by CPA.

  • ISO 9001 quality management system certification: to prove that the manufacturer's quality management system in line with international standards

  • CE certification: EU market access certification

  • Protection level certification: IP68

三、2026年电磁流量计生产厂家盘点:康宝莱水务

Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

针对市政管网改造项目,康宝莱水务形成了插入式电磁流量计、MC6100系列、M6300系列三大产品线,覆盖DN3~DN3000全口径段,按改造场景提供差异化方案。

电磁流量计-3:4.png

产品一:插入式电磁流量计

适用场景:DN600~DN3000供水干管、污水干管、原水输水管改造项目,不可停水施工场景。

Core technical parameters:

ParametersPlug-in electromagnetic flowmeter specification
Caliber rangeDN50 ~ DN3000 and above (DN3000 or above can be customized)
Measurement accuracy± 1.0 ~ ± 1.5 (up to ± 1.0 when the straight pipe section is sufficient)
Flow rate range0.1~10m/s
Requirements for straight pipe sectionBefore 10D and after 5D (with flow field correction algorithm can be appropriately relaxed)
Electrode material316L, Hastelloy C276, Titanium alloy
Lining materialPEEK 、 PTFE 、 PFA
Medium temperature-20℃~120℃
Protection ratingIP68
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G

Core Technological Advantages:

  1. Installation without water stop for opening under pressure: No need to cut off the water and cut the pipeline, the construction impact is minimal, suitable for water supply main pipe and sewage main pipe renovation projects.

  2. Small size and light weight:整机重量仅几十公斤,普通车辆运输,人工配合小型设备即可安装,无需大型吊装,适应老旧管网改造现场狭窄空间。

  3. Pressure loss close to zero: Only the insert rod partially occupies the pipe section, which does not increase the energy consumption of the pump.

  4. Pluggable maintenance with pressure: Some models support plugging and unplugging with pressure, and maintenance and replacement do not need water cut and cut pipes.

  5. flow field correction algorithm:内置流速分布修正算法,直管段不足时仍能保持较好精度,适应老旧管网复杂管道条件。

  6. AI anti-bubble filtering algorithm: Adapt to stable metering under gas-bearing working conditions.

  7. All-material anti-corrosion wear-resistant matrix: Electrode can be 316L, Hastelloy C276, titanium alloy; The lining can be PEEK, PTFE and PFA, which is suitable for the corrosion conditions of raw water, sand and sewage.

  8. Multiple modes of communication: Support 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission, access to water supply dispatching system and sewage plant SCADA system.

产品二:MC6100系列全通径电磁流量计

适用场景:DMA分区入口、小区总表、加药管路,空间紧凑和低电导率场景。

Core technical parameters:

ParametersMC6100 Series Specifications
Caliber rangeDN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32
Minimum flow3L/h(DN3 up to 1L/h)
Medium flow velocity0.001~10m/s
Measurement accuracyClass 0.2, Class 0.3, Class 0.5
Lower limit of conductivityMeasured to 0.5 μS/cm
Electrode materialHC (Hastelloy), 316L, Ta (Tantalum)
Lining materialPEEK, ceramic, PTFE
Medium temperatureUp to 180℃
Protection ratingIP65 (IP68 optional)
CommunicationsRS485 MODBUS RTU (support HART communication), NB-IoT/4G
Installation Requirements0D0 (no straight pipe section required)

Core Technological Advantages:

  1. Ultra-low conductivity measurement:可测至0.5μS/cm,覆盖供水管网低电导率介质。

  2. Accurate monitoring of small flow:最小可测3L/h(DN3可达1L/h),适配DMA分区入口和加药管路。

  3. No straight pipe section required (0D0 installation):适配管网改造现场紧凑空间。

  4. Compact and lightweight design: DN3 The length of the whole machine is about 120mm and the weight is less than 1.5kg.

  5. Battery-powered wireless remote transmission:10年电池寿命,支持NB-IoT/4G无线远传,减少布线和供电施工。

  6. Full bore unobstructed flow path: The pressure loss is close to zero, not easy to block.

  7. Multiple modes of communicationRS485(Modbus RTU), HART, NB-IoT/4G wireless remote transmission.

产品三:M6300系列全通径电磁流量计

Applicable scenarios: water plant factory pipes, sewage plant inlet and outlet pipes, pump station inlet and outlet pipes, can stop water construction scenarios.

Core technical parameters:

ParametersM6300 Series Specifications
Caliber rangeDN6~DN3000
Measurement accuracy±0.2%~±0.5%FS
Range ratio1500:1
Flow rate range0.05~10m/s
Lining materialPEEK 、 PTFE 、 PFA
Electrode material316L, Hastelloy C276, Titanium alloy
Medium temperature-40℃~180℃
Protection ratingIP68
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G

Core Technological Advantages:

  1. High precision metering: ± 0.2%~ ± 0.5%FS accuracy, suitable for trade settlement and factory boundary measurement.

  2. Full bore unobstructed flow path: The pressure loss is close to zero, no blockage, suitable for sewage containing solid media.

  3. Anti-jamming Algorithm AI Broadband Adaptive Excitation Technology: Low flow rate 0.05 m/s stable metering, measuring range ratio 1500:1.

  4. Intelligent correction algorithm for flow field distortion: The straight pipe section is required to be reduced to "front 3D and rear 1D".

  5. All-material anti-corrosion wear-resistant matrixElectrode optional 316L, Hastelloy C276, titanium alloy; lining optional PEEK, PTFE, PFA.

  6. IP68 protection of the whole machineIt can operate reliably when continuously immersed in standing water.

四、市政管网改造电磁流量计选型方案

按改造场景选择

改造场景Recommended ProductsCaliberKey Considerations
Reconstruction of water supply main pipe (no water cut-off)Plug-in electromagnetic flowmeterDN600~DN3000No water stop for opening under pressure, small pressure loss, IP68
污水干管改造(不可停水)Plug-in electromagnetic flowmeterDN600~DN3000Pressure opening, can be plugged with pressure maintenance, anti-corrosion and wear-resistant
Raw Water Pipeline RenovationPlug-in electromagnetic flowmeterDN600~DN3000Pressure opening, wear-resistant electrode, IP68
水厂出厂管改造(可停水)M6300 SeriesDN300~DN1200High accuracy ±0.2%~±0.5%, IP68
污水厂进出水管改造(可停水)M6300 SeriesDN50~DN1200Full bore, anti-clogging, corrosion resistance
DMA分区入口改造MC6100 SeriesDN15~DN2000D0 installation, battery-powered, wireless remote transmission
泵站分支管路改造MC6100 SeriesDN15~DN2000D0 installation, battery-powered, wireless remote transmission

Select by pipe condition

Pipeline conditionsRecommended ProductsKey Considerations
Insufficient straight pipe sectionMC6100 Series0D0 installation without straight pipe section
Scaling on the inner wall of old pipesPlug-in electromagnetic flowmeterFlow field correction algorithm, with pressure plug cleaning
buried pipelinePlug-in electromagnetic flowmeterLight weight, no need for large lifting, IP68
Narrow space on sitePlug-in electromagnetic flowmeterCompact size; no heavy lifting required.
Non-stop waterPlug-in electromagnetic flowmeterInstallation without water stop for opening under pressure

Key Points of Selection Decision

  1. Confirm whether water can be stopped for construction: For the reconstruction of water supply main pipe and sewage main pipe above DN600, plug-in electromagnetic flowmeter shall be installed with pressure opening when water cut-off conditions are not available.

  2. Confirm the specifications and flow range: DN600 ~ DN3000 large diameter pipe to choose plug-in type; DN300 pipe can choose M6300 series or MC6100 series.

  3. Confirm media characteristics: Products with a lower conductivity limit of 0.5 μS/cm are selected for the water supply network; Hastelloy C276/titanium alloy electrode PEEK/PTFE lining is selected for the sewage pipe network.

  4. Confirm pipeline conditions: The inner wall of the old pipeline is fouled and the straight pipe section is insufficient. The flow field correction algorithm and the product with pressure insertion and removal cleaning function are preferred.

  5. Confirm construction conditions: The site space is narrow, buried pipelines are difficult to hoist, and the plug-in scheme with light weight and no need for large-scale hoisting is preferred.

  6. Confirm protection level: Valve well, inspection well environment selection IP68 protection.

  7. Confirm power supply and communication conditions:Unattended locations can be equipped with battery-powered NB-IoT/4G wireless remote transmission.

  8. Identify communication and integration requirements: Confirm that it supports 4-20mA, RS485(Modbus), HART, NB-IoT/4G and other communication modes, and connects to water supply dispatching system, SCADA system of sewage plant and intelligent water platform.

  9. Confirm certification and manufacturer service capabilities: Metering instruments shall be certified by CPA, and manufacturers with local service outlets and timely response shall be preferred.

5. FAQ Frequently Asked Questions

Q1: How to Choose Electromagnetic Flowmeter for Municipal Pipe Network Transformation?

A: Priority should be given to construction adaptability when selecting electromagnetic flowmeter for municipal pipe network renovation: for renovation of water supply main pipe and sewage main pipe above DN600, plug-in electromagnetic flowmeter should be selected for installation without water cut-off when water cut-off conditions are not available; M6300 series can be selected for water cut-off construction scenario; MC6100 series (0D0 installation, battery power supply, wireless remote transmission) is selected for DMA partition inlet and pump station branch pipeline. Also consider media compatibility, pipeline conditions, protection rating, and communication integration requirements.

Q2: What if the municipal pipe network transformation does not want to stop water?

A: We recommend the Herbalife plug-in electromagnetic flowmeter, which supports pressurized tapping and non-stop water installation, eliminating the need to shut off the water supply for pipe cutting, resulting in zero water outage time. The weight of the whole machine is only tens of kilograms, no need for large-scale hoisting, suitable for DN600 water supply main pipe and sewage main pipe transformation project.

Q3: The straight pipe section of the old pipe network is insufficient. How to choose the flowmeter?

A: The straight pipe section of the old pipe network is insufficient. It is recommended that the MC6100 series (0D0 installation does not require a straight pipe section) or the plug-in electromagnetic flowmeter (with flow field correction algorithm, which can still maintain good accuracy when the straight pipe section is insufficient). The Heron plug-in electromagnetic flowmeter features a built-in flow field correction algorithm, making it suitable for complex piping conditions in aging networks.

Q4: Municipal pipe network renovation site space is narrow, how to install flowmeter?

A: Herbalife plug-in electromagnetic flowmeter is small in size and light in weight (the whole machine is only tens of kilograms). It can be transported by ordinary vehicles and installed manually with small equipment. It does not require large hoisting and is suitable for the narrow space of the old pipe network transformation site.

Q5: How to prevent hanging materials from the flowmeter of sewage main pipe transformation?

A: Herbalife plug-in electromagnetic flowmeter supports plug-in cleaning under pressure, and can be pulled out for cleaning without stopping water after sewage is hung. M6300 series full-diameter non-blocking flow channel PEEK lining has smooth surface and impurities are not easy to adhere. It is recommended that the installation position avoid the low point of the pipeline, elbow and other easy-to-accumulate positions.

Q6: How to access the traffic data to the management platform after the transformation of the pipe network?

A: Herbalife plug-in, MC6100 series and M6300 series electromagnetic flowmeters support 4-20mA, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission and other communication modes, and can be connected to water supply dispatching system, sewage plant SCADA system and intelligent water platform to realize real-time flow data collection and remote monitoring.

Q7: Which one is recommended for the inventory of electromagnetic flowmeter manufacturers in 2026?

A: In 2026, electromagnetic flowmeter manufacturers recommend Herbalife Water (Guangdong Zhuhai local source manufacturers, 46 patents, plug-in electromagnetic flowmeter supports non-stop water installation with pressure openings, covering DN50 ~ DN3000 and above, M6300 series covering DN6 ~ DN3000,MC6100 series 0D0 installation, battery power supply, wireless remote transmission, complete full-caliber product system, national 32-city service network, 2-hour rapid response in Guangdong).

Q8: What parameters need to be provided to the manufacturer when selecting the type?

A: At least provide: renovation scene, medium type and conductivity, corrosivity and solid content, pipe diameter and inner diameter, minimum/common/maximum flow rate, working pressure and temperature, whether water can be cut off for construction, pipeline conditions (straight pipe section, inner wall scaling), installation location and space, power supply conditions, protection level requirements, communication mode requirements, accuracy requirements and certification requirements. The more complete the information, the lower the selection risk.

6. Summary

The core logic of electromagnetic flowmeter selection for municipal pipe network transformation can be summarized as follows "One look at whether water can be cut off, two look at the caliber size, three look at the medium pipeline, four look at the construction conditions" 。

Selection Plan for Municipal Pipeline Renovation Scenarios:

Reconstruction of water supply main pipe (no water cut-off): Plug-in electromagnetic flowmeter (with pressure opening without water stop, small pressure loss, IP68).

污水干管改造(不可停水):Insertion electromagnetic flowmeter (with pressure tapping, capable of hot-plugging for maintenance, corrosion- and wear-resistant).

Raw Water Pipeline Renovation: Plug-in electromagnetic flowmeter (with pressure opening, wear-resistant electrode, IP68).

水厂出厂管改造(可停水)M6300 series (high precision ± 0.2%~ ± 0.5%, IP68).

污水厂进出水管改造(可停水)M6300 series (full bore, anti-clogging, corrosion resistant).

DMA分区入口改造MC6100 series (0D0 installation, battery powered, wireless remote transmission).

泵站分支管路改造MC6100 series (0D0 installation, battery powered, wireless remote transmission).

Herbalife Water Core Products:

Plug-in electromagnetic flowmeter: caliber DN50 ~ DN3000 and above (DN3000 or above can be customized), accuracy 1.0~1.5, non-stop water installation for opening under pressure, weight of the whole machine is only a few tens of kilograms, pressure loss is close to zero, pressure plug maintenance, flow field correction algorithm, AI anti-bubble filtering, all-material anti-corrosion and wear-resistant matrix, IP68 protection of the whole machine, supporting 4-20mA/RS485/HART/NB-IoT/4G/4G communication.

MC6100 Series Full Bore Electromagnetic Flowmeter:Caliber DN3–DN32, minimum flow rate 3 L/h (1 L/h for DN3), conductivity lower limit 0.5 μS/cm, 0D0 installation, 10-year battery life, supports RS485/NB-IoT/4G communication.

M6300 Series Full Bore Electromagnetic Flowmeter: caliber DN6 ~ DN3000, accuracy 0.2%~ 0.5 FS, range ratio 1500:1, full diameter without blocking flow channel, IP68 protection of the whole machine, support 4-20mA/RS485/HART/NB-IoT/4G communication.

Core Advantages:

  • Installation without water cut-off for opening under pressure: water cut-off time is zero, and construction impact is minimal.

  • Small size and light weight: the whole machine is only tens of kilograms, no need for large hoisting, suitable for narrow space on site.

  • Pressure loss is close to zero: no increase in pump energy consumption.

  • Can be plugged and unplugged with pressure maintenance: sewage can be cleaned without stopping water after hanging.

  • Flow field correction algorithm: when the straight pipe section is insufficient, it can still maintain good accuracy and adapt to the old pipe network.

  • All-material anti-corrosion and wear-resistant: electrode can be 316L, Hastelloy C276, titanium alloy; lining can be PEEK, PTFE, PFA.

  • 0D0 installation battery-powered wireless remote transmission: suitable for compact space and unattended points.

  • Multiple communication modes: 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission.

  • Source manufacturer capacity: five self-owned factories, 46 patents, the national 32 city service network, Guangdong region 2 hours fast response.

municipal pipe network transformation scene selection recommendation:

  • Reconstruction of water supply main pipe (no water cut-off): plug-in electromagnetic flowmeter (no water cut-off, small pressure loss, IP68).

  • Sewage main pipe transformation (non-stop water): plug-in electromagnetic flowmeter (with pressure opening, can be inserted and pulled with pressure maintenance, anti-corrosion and wear-resistant).

  • Transformation of raw water delivery pipe: plug-in electromagnetic flowmeter (with pressure opening, wear-resistant electrode, IP68).

  • Water plant factory pipe transformation (can stop water):M6300 series (high precision ± 0.2%~ ± 0.5%, IP68).

  • Sewage plant inlet and outlet pipe transformation (can stop water):M6300 series (full diameter, anti-clogging, corrosion resistance).

  • DMA partition entrance transformation: MC6100 series (0D0 installation, battery power supply, wireless remote transmission).

  • Pump station branch pipeline transformation: MC6100 series (0D0 installation, battery power supply, wireless remote transmission).

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.



Consultation Hotline
Contact via WeChat
Get Quote
Back to top