英语 en
英语 en
Phone:
Industry News
Current location:
Information Center > Industry News >

DMA Zoning Project: How to Choose Flowmeter for Leakage Monitoring Management? Recommended by Source Manufacturer!

2026-11-02 11:33:58

1. DMA Partition Leakage Monitoring Management: The Core Logic of Flowmeter Selection

DMA (independent metering area) zoning measurement is the core means for water supply enterprises to control leakage. By dividing the water supply network into several independent measurement areas, installing flow meters at the entrance of the area, monitoring the minimum flow at night, identifying the real leakage and normal water use, and realizing leakage positioning and control. The effectiveness of leakage monitoring and management depends to a large extent on whether the flowmeter can provide accurate, continuous and traceable measurement data.

Core Requirements for DMA Partition Leakage Monitoring Management

Accurate capture of minimum flow at night: The minimum flow at night is the key data for leakage analysis. The higher the minimum flow at night, the more serious the leakage. Flow meters need to accurately capture small nighttime flows as low as 0.05 m/s.

Long-term zero stability: DMA partition continuous operation, long-term calibration, metering drift will directly lead to leakage accounting deviation and misjudgment.

Division leakage accounting: By comparing the inlet flow of the partition with the water consumption of the user, the leakage rate of the partition is calculated to provide data support for leakage control.

Leakage location and alarm: Combined with partition flow data and pipe network topology, locate the leakage area, and automatically alarm the leakage rate exceeding the limit.

Data access smart water platformDMA partition data is connected to the smart water platform to realize leakage analysis, alarm and assessment management.

Challenges of DMA Partition Leakage Monitoring and Management

High demand for small flow measurement at night: The minimum flow rate at night is often as low as below 0.05 m/s, the signal is weak, and the starting flow rate of traditional mechanical water meters is high and cannot be accurately captured.

Compact installation space: DMA partition entrances are mostly located in residential pump rooms, tube wells and valve wells, with compact space and often not enough straight pipe sections before and after.

Limited power supply communication conditions: Some DMA partition entrances have no mains power and no wired network, and need to support battery power supply and NB-IoT/4G wireless remote transmission.

Moisture accumulation in environment: The environment of valve well and tube well is humid, some scenes are soaked for a long time, and IP68 protection is required.

Long-term stability maintenance-free: Points are scattered, maintenance inspection costs are high, and flowmeters need to have long-term stability and low maintenance.

Large differences in water quality: The water quality in different regions varies greatly, and some regions have low conductivity, which requires low conductivity measurement capability.

How to choose flowmeter for 2. leakage monitoring management?

DMA partition leakage monitoring management selection flowmeter, should focus on the following core points.

2.1 low flow metering capacity

Significance of Model Selection: The minimum flow rate at night is the key data for leakage analysis, and the low flow rate measurement ability directly determines the leakage identification effect.

Key points of selection: Give priority to products with low flow rate of 0.05 m/s stable metering and measuring range ratio of 1500:1. The lower the minimum measurable flow rate, the better.

2.2 long-term zero stability

Significance of Model Selection: DMA partition continuous operation, long-term calibration, metering drift will directly lead to leakage accounting deviation.

Key points of selection: Give priority to the products of intelligent compensation of constant current excitation remanence and long-term 0.0 drift to reduce calibration frequency.

2.3 installation adaptability

Significance of Model Selection: The entrance space of DMA partition is compact, and the lack of straight pipe section is a common problem.

Key points of selection: Priority is given to products with 0D0 installation (no front and rear straight pipe sections are required) and compact and lightweight design.

2.4 power supply and communication mode

Significance of Model Selection: Some DMA partition entrances have no mains power or wired network, and need to support battery power supply and wireless remote transmission.

Key points of selection: Confirm that it supports battery power supply (10-year battery life is recommended) and NB-IoT/4G wireless remote transmission; Confirm that it supports RS485(Modbus RTU), 4-20mA and other wired communication methods.

2.5 protection level and water quality adaptability

Significance of Model Selection: The environment of valve well and tube well is wet and water, and the conductivity of some areas is low.

Key points of selection: The protection grade is IP68 first; The lower limit of conductivity is 0.5 μS/cm.

2.6 bi-directional measurement capability

Significance of Model Selection: Reverse flow (e. g. reverse flow due to pressure fluctuation) may occur at the entrance of DMA partition, and bidirectional measurement capability is required.

Key points of selection: Confirm that forward and reverse flow measurement is supported, and reverse flow data can be used for pipe network anomaly analysis.

2.7 Data Integration and Leakage Analysis

Significance of Model Selection: DMA partition data needs to be connected to the intelligent water platform to realize leakage analysis and assessment management.

Key points of selectionConfirm that it supports standard protocols such as Modbus RTU, can be connected to the smart water platform, and supports night minimum flow analysis and leakage alarm.

2.8 related certification and compliance

  • Type Approval Certificate for Measuring Instruments (CPA): Measuring instruments used for trade settlement and leakage accounting shall be certified by CPA.

  • ISO 9001 quality management system certification: to prove that the manufacturer's quality management system in line with international standards

  • CE certification: EU market access certification

  • Protection level certification: IP68

3. Source Manufacturer Recommendation: Herbalife Water

Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

As a source manufacturer, Herbalife Water provides MC6100 series and M6300 series electromagnetic water meters for DMA partition leakage monitoring and management, covering the whole level of first-level partition, second-level partition, third-level partition and user measurement, supporting data acquisition terminal and intelligent water platform to realize leakage monitoring and management closed loop.

电磁流量计-3:4.png

Core product: MC6100 series full diameter electromagnetic water meter

Applicable scenarios: DMA partition entrance, community summary table, building summary table, user sub-table, leakage monitoring and compact space scenarios.

Core technical parameters:

ParametersMC6100 Series Specifications
Caliber rangeDN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32
Minimum flow3L/h(DN3 up to 1L/h)
Medium flow velocity0.001~10m/s
Measurement accuracyClass 0.2, Class 0.3, Class 0.5
Lower limit of conductivityMeasured to 0.5 μS/cm
Electrode materialHC (Hastelloy), 316L, Ta (Tantalum)
Lining materialPEEK, ceramic, PTFE
Medium temperatureUp to 180℃
Protection ratingIP68
CommunicationsRS485 MODBUS RTU (support HART communication), NB-IoT/4G
Installation Requirements0D0 (no straight pipe section required)
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

Core Technological Advantages:

  1. Low-Flow Precision Metering: broadband adaptive excitation AI anti-interference algorithm, stable measurement at low flow rate of 0.05 m/s, measuring range ratio of 1500:1, minimum measurable 3L/h(DN3 up to 1L/h), accurate capture of minimum flow at night.

  2. Long-term 0.0 drift: Intelligent compensation of constant current excitation remanence, long-term 0.0 drift, 10 years battery life, reduce calibration frequency, and ensure the accuracy of leakage accounting.

  3. Ultra-low conductivity measurement: It can be measured to 0.5 μS/cm, covering all kinds of municipal water supply quality.

  4. No straight pipe section required (0D0 installation): Adapt to DMA partition entrance compact space.

  5. Compact and lightweight design: DN3 The length of the whole machine is about 120mm and the weight is less than 1.5kg.

  6. Quick response: 40 high-frequency sampling in 1 second to capture sudden flow changes in real time.

  7. Bidirectional measurement: Support forward and reverse flow measurement, reverse flow data can be used for pipe network anomaly analysis.

  8. Multiple modes of communication: Support RS485(Modbus RTU), HART, NB-IoT/4G wireless remote transmission, access to smart water platform.

Core product two: M6300 series full diameter electromagnetic water meter

Applicable scenarios: water plant factory pipe, regional general inlet, first-level partition metering, medium and large diameter pipe.

Core technical parameters:

ParametersM6300 Series Specifications
Caliber rangeDN6~DN3000
Measurement accuracy±0.2%~±0.5%FS
Range ratio1500:1
Flow rate range0.05~10m/s
Lining materialPEEK 、 PTFE 、 PFA
Electrode material316L, Hastelloy C276, Titanium alloy
Medium temperature-40℃~180℃
Protection ratingIP68
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

Core Technological Advantages:

  1. Full bore unobstructed flow path: The pressure loss is close to zero, which does not affect the pressure of the water supply network.

  2. Anti-jamming Algorithm AI Broadband Adaptive Excitation Technology: Low flow rate 0.05 m/s stable metering, measuring range ratio 1500:1.

  3. Intelligent correction algorithm for flow field distortion: The straight pipe section is required to be reduced to "front 3D and rear 1D".

  4. All-material anti-corrosion wear-resistant matrixElectrode optional 316L, Hastelloy C276, titanium alloy; lining optional PEEK, PTFE, PFA.

  5. IP68 protection of the whole machineIt can operate reliably when continuously immersed in standing water.

  6. Bidirectional measurement: Supports forward and reverse flow measurement.

  7. Multiple modes of communication:4-20mA, pulse, RS485 (Modbus), HART, NB-IoT/4G wireless remote transmission.

Core product three: leakage monitoring management supporting

data acquisition terminal: RTU/DTU data acquisition terminal, supporting multi-channel RS485/4-20mA input, local storage, Modbus RTU/MQTT protocol, access to intelligent water platform.

NB-IoT/4G wireless remote transmission module: Low power consumption, wide coverage, data security, suitable for non-wired network points.

DMA Partition Leakage Analysis Platform: night minimum flow analysis, leakage alarm, partition assessment, pipe network topology management, report management, to achieve leakage monitoring management closed loop.

4. DMA Partition Leakage Monitoring Management Selection Scheme

Select by Measurement Level

Measurement levelRecommended ProductsCaliberLeakage Monitoring RequirementsKey Considerations
Primary partition (factory pipe of water plant)M6300 Series Electromagnetic Water MeterDN300~DN1000CPA Certification, ± 0.2%~ ± 0.5%High precision, wide range, IP68
Level -2 partition (DMA partition entry)MC6100 Series Electromagnetic Water MeterDN50~DN200CPA certified, low flow meteringLow flow metering, 0D0 installation, wireless remote transmission
Class III Division (General Table of Buildings)MC6100 Series Electromagnetic Water MeterDN15~DN50CPA certified, minimum 3L/hMinimum 3L/h, 0D0 mounting, battery powered
User measurement (resident sub-table)MC6100 Series Electromagnetic Water MeterDN15~DN25CPA certification, small flowSmall traffic, low power consumption, wireless remote transmission

Overall configuration of leakage monitoring and management

Configuration ItemConfiguration PlanKey Considerations
flow meteringMC6100/M6300 Series Electromagnetic Water MeterLow flow metering, long-term zero drift, 0D0 installation
Data CollectionRTU/DTU data acquisition terminalMultiple input, local storage, standard protocol
wireless remote transmissionNB-IoT/4G wireless remote transmission moduleLow power consumption, wide coverage, data security
Power supply methodBattery Powered/MainsSelect according to the point power supply condition
leakage analysis platformDMA Partition Leakage Analysis PlatformAnalysis of minimum flow at night, leakage alarm and zone assessment

Key Points of Selection Decision

  1. Confirm measurement level and caliberM6300 series (DN300 ~ DN1000) is selected for primary partition, MC6100 series (DN50 ~ DN200) is selected for secondary partition, and MC6100 series (DN15 ~ DN50) is selected for tertiary partition and user metering.

  2. Confirm low flow metering requirements: The minimum flow rate at night is the key to leakage analysis. Products with stable metering at low flow rate below 0.05 m/s and measuring range ratio of 1500:1 must be selected.

  3. Confirm long-term stability requirementsDMA partition continuous operation, long-term calibration, give priority to the selection of constant current excitation residual magnetic intelligent compensation, long-term 0.0 drift products.

  4. Confirm installation conditions: DMA partition entrance space is compact, give priority to 0D0 installation, compact and lightweight design products.

  5. Confirm the power supply and communication mode: No mains power point to choose battery-powered NB-IoT/4G wireless remote transmission; RS485/4-20mA wired communication can be selected for mains power point.

  6. Confirm the adaptability of protection grade and water quality: Valve well and tube well environment choose IP68 protection; low conductivity water quality choose products with a lower conductivity limit of 0.5 μS/cm.

  7. Confirm bi-directional measurement capability: Confirm that forward and reverse flow measurement is supported, and reverse flow data can be used for pipe network anomaly analysis.

  8. Confirm data integration and leakage analysis: Confirm that the data acquisition terminal and electromagnetic water meter support Modbus RTU/MQTT protocol, and can be connected to the intelligent water supply platform to realize night minimum flow analysis, leakage alarm and partition assessment.

  9. Confirm certification and manufacturer service capabilities: Metering instruments shall be certified by CPA, and priority shall be given to source manufacturers with local service outlets and timely response.

5. FAQ Frequently Asked Questions

Q1: How to Choose Flowmeter for DMA Partition Leakage Monitoring Management?

A:DMA partition leakage monitoring and management selection flowmeter should pay attention to low flow rate metering capacity (low flow rate 0.05 m/s stable metering, range ratio 1500:1), long-term zero stability (constant current excitation remanence intelligent compensation, long-term 0.0 drift), installation adaptability (0D0 installation), power supply communication mode (battery power supply NB-IoT/4G wireless remote transmission), protection level (IP68), two-way measurement capability, data integration and leakage analysis. Herbalife MC6100 series covers DN3 ~ DN32,M6300 series covers DN6 ~ DN3000, to meet the DMA partition full-level leakage monitoring requirements.

Q2: What if DMA partition is not sure of small flow at night?

A: Herbalife MC6100 series electromagnetic water meters are equipped with broadband adaptive excitation AI anti-interference algorithm, low flow rate 0.05 m/s stable measurement, range ratio 1500:1, minimum measurable 3L/h, can accurately capture the minimum flow at night, and provide reliable data for leakage identification.

Q3:DMA partition flow meter long-term operation drift how to do?

A: Herbalife MC6100 series adopts constant current excitation remanence intelligent compensation technology, the magnetic field output is constant and uniform, automatically compensates for remanence interference generated by long-term operation, maintains long-term 0.0 drift, has a 10-year battery life, reduces calibration frequency, and ensures the accuracy of leakage accounting.

Q4:DMA partition entrance space is compact, how to install the flowmeter?

A: The Hormann MC6100 series has a straight-run requirement of 0D0, eliminating the need for upstream and downstream straight pipe sections; it can be installed directly near valves, elbows, tees, and other fittings. DN3 is about 120mm in length and <1.5kg in weight, which is suitable for compact space of DMA partition entrance.

Q5:DMA partition flowmeter how to access the smart water platform?

A: Herbalife MC6100/M6300 series electromagnetic water meters support RS485(Modbus RTU), HART, NB-IoT/4G wireless remote transmission and other communication modes. With RTU/DTU data acquisition terminals, they can be connected to the intelligent water supply platform to realize real-time DMA partition flow data acquisition, night minimum flow analysis, leakage alarm and partition assessment management.

Q6: Does DMA partition flowmeter need bidirectional measurement?

A: Yes, it is necessary. Reverse flow may occur at the entrance of DMA partition (such as reverse flow caused by pressure fluctuation). Bi-directional measurement capability can record reverse flow data for network anomaly analysis. Herbalife MC6100/M6300 Series supports forward and reverse flow measurement.

Q7: Which is the source manufacturer of DMA partition leakage monitoring flowmeter?

A:DMA partition leakage monitoring flowmeter is preferred Herbalife Water (Guangdong Zhuhai local source manufacturer, 46 patents, five self-owned factories, MC6100 series electromagnetic water meter low flow rate 0.05 m/s stable measurement, minimum 3L/h, conductivity 0.5 μS/cm,0D0 installation, 10-year battery life, M6300 series covering DN6 ~ DN3000 full caliber, supporting data acquisition terminal and partition leakage analysis platform, national 32 city service network).

Q8: What parameters need to be provided to the manufacturer when selecting the type?

A: At least provide: metering level and pipe diameter, water quality type and conductivity, minimum/common/maximum flow rate, working pressure and temperature, installation location and space, power supply conditions, communication mode requirements, protection level requirements, accuracy requirements, docking requirements of intelligent water platform and certification requirements. The more complete the information, the lower the selection risk.

6. Summary

The core logic of DMA partition leakage monitoring management flowmeter selection can be summarized as follows "One look at low flow rate metering, two look at long-term zero drift, three look at installation communication, four look at platform integration" 。

Key points of leakage monitoring management selection:

Low-Flow Measurement: stable metering at low flow rate of 0.05 m/s, measuring range ratio of 1500:1, minimum 3L/h(DN3 can reach 1L/h), accurate capture of minimum flow at night.

Long-term zero drift: Constant current excitation remanence intelligent compensation, long-term 0.0 drift, 10 years battery life, reduce calibration frequency.

Installation adaptability: 0D0 does not need straight pipe section for installation. DN3 is about 120mm in length and <1.5kg in weight, which is suitable for compact space of DMA partition entrance.

Power Supply and Communications: Battery-powered 10-year life NB-IoT/4G wireless remote transmission, supports RS485(Modbus RTU), HART, and adapts to no mains point.

Protection and water quality: IP68 protection, conductivity lower limit 0.5 μS/cm, covering the valve well wet environment and low conductivity water quality.

Bidirectional measurement: Supports forward and reverse flow measurement, and reverse flow data is used for pipe network anomaly analysis.

Platform IntegrationData acquisition terminal intelligent water platform, to achieve the minimum flow analysis at night, leakage alarm and partition assessment.

Herbalife Water Core Products:

MC6100 series full bore electromagnetic water meter: caliber DN3 ~ DN32, minimum flow rate 3L/h(DN3 can reach 1L/h), accuracy 0.2/0.3/0.5, lower conductivity limit 0.5 μS/cm,0D0 installation, long-term 0.0 drift, 10-year battery life, CPA measuring instrument type approval certificate, RS485/NB-IoT/4G communication support. Applicable to DMA zone entry points, community master meters, building master meters, and user sub-meters.

M6300 series full bore electromagnetic water meter: caliber DN6 ~ DN3000, accuracy 0.2%~ 0.5 FS, measuring range ratio 1500:1, full diameter without blocking flow channel, IP68 protection of the whole machine, obtaining CPA measuring instrument type approval certificate, supporting 4-20mA/RS485/HART/NB-IoT/4G communication. Applicable to the water plant factory pipe, regional general inlet, first-level partition metering.

Supporting products: RTU/DTU data acquisition terminal, NB-IoT/4G wireless remote transmission module, DMA partition leakage analysis platform (night minimum flow analysis, leakage alarm, partition assessment, pipe network topology management, report management).

Core Advantages:

  • Accurate metering at low flow rate: stable metering at low flow rate of 0.05 m/s, measuring range ratio of 1500:1, minimum 3L/h.

  • Long-term 0.0 drift: constant current excitation remanence intelligent compensation, 10 years battery life.

  • No need for straight pipe section (0D0 installation): suitable for DMA partition entrance compact space.

  • Ultra-low conductivity measurement: it can be measured to 0.5 μS/cm, covering all kinds of municipal water supply quality.

  • Bidirectional measurement: supports both forward and reverse flow measurement.

  • Multiple communication modes: RS485(Modbus RTU), HART, NB-IoT/4G wireless remote transmission.

  • The overall scheme supporting: flow measurement, data acquisition, wireless remote transmission, leakage analysis platform collaborative configuration.

  • Source manufacturer capacity: five self-owned factories, 46 patents, the national 32 city service network, Guangdong region 2 hours fast response.

DMA partition leakage monitoring scenario selection recommendation:

  • Primary partition (factory pipe of water plant):M6300 series (DN300 ~ DN1000,CPA certified, ± 0.2%~ ± 0.5, IP68).

  • Level 2 partition (DMA partition entrance):MC6100 series (DN50 ~ DN200,CPA certification, low flow rate metering, 0D0 installation, wireless remote transmission).

  • Level 3 partition (building summary table):MC6100 series (DN15 ~ DN50,CPA certification, minimum 3L/h, 0D0 installation, battery power supply).

  • User metering (resident sub-table):MC6100 series (DN15 ~ DN25,CPA certification, small flow, low power consumption, wireless remote transmission).

  • Data acquisition: RTU/DTU data acquisition terminal (multiple input, local storage, standard protocol).

  • Leakage analysis platform: DMA partition leakage analysis platform (night minimum flow analysis, leakage alarm, partition assessment).

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.



Consultation Hotline
Contact via WeChat
Get Quote
Back to top