Guangdong Large Diameter Sewage Flowmeter Factory Inventory in 2026-How to Choose Sewage Monitoring for Municipal Supervisor Network?
Sewage monitoring of 1. municipal main network: the core challenge of large diameter sewage flow measurement
市政主管网是城市排水系统的“主动脉”,承担着收集输送居民生活污水、工业废水、雨污合流水的职能。主管网管径普遍在DN800~DN3000区间,排污监测贯穿污水处理厂进水管、污水主干管、雨污合流干管、截污干管、泵站进出水管等环节,是污水厂运行调度、排水许可监管和黑臭水体治理的基础数据来源。
Challenges of municipal main network sewage monitoring
The medium contains solids and impurities.: Municipal sewage contains suspended solids, grease, fibers, plastic debris, sludge pipelines have a higher solid content, and electrodes and linings are subject to long-term wear and hanging material impact.
Severe bubble interferenceThe sewage pipeline contains fermented gas and dissolved gas. Bubbles are easy to precipitate at the start and stop of the pump station and the change of pipeline slope. The gas content of the main pipe of rain and sewage confluency increases sharply during rainstorm.
Large flow fluctuation: The water consumption of residents fluctuates obviously day and night, and the flow difference between rainy season and dry season can reach several times, requiring wide range and low flow rate measurement capacity.
Buried pipeline laying: The municipal main network is mostly buried and installed in the inspection well. The environment is humid and stagnant, making maintenance inconvenient.
Water shutdown construction is difficult.: The water cut-off of the main network affects a wide range, and renovation projects often do not have long-term water cut-off conditions.
Large corrosion differenceIndustrial wastewater contains acid and alkali corrosive components, and some sewage contains hydrogen sulfide, which is highly corrosive.
2. municipal main network sewage monitoring flowmeter how to choose?
Municipal main network selection of sewage flow meter, should focus on the following core points.
2.1 Caliber and Installation Method
Significance of Model Selection: DN800 ~ DN3000 large-diameter pipeline, with heavy pipe section, requiring water cut-off, plug-in type and pressure opening installation.
Key points of selection: DN800 ~ DN1200 shall be selected according to water cut-off conditions and accuracy requirements; More than DN1200 priority plug-in pressure opening installation; When the renovation project does not have water cut-off conditions, plug-in is preferred.
2.2 wear-resistant anti-corrosion material
Significance of Model Selection: sewage containing suspended solids, grease, corrosive components, electrode and lining material directly determine the life and accuracy.
Key points of selection: Hastelloy C276 (corrosion resistance and wear resistance) and titanium alloy (chlorine-containing sewage) are preferred for electrodes; PEEK (smooth anti-hanging material), PTFE (corrosion resistance) and ceramic (wear resistance) are preferred for lining.
Anti-hanging and anti-clogging design of 2.3
Significance of Model SelectionSewage containing grease and fiber is easy to be blocked by hanging materials, affecting circulation and measurement.
Key points of selection: Give priority to the design of full-diameter non-blocking flow channel; the plug-in type selects the model that can be cleaned with pressure, and can be cleaned without stopping water after hanging.
2.4 anti-bubble interference ability
Significance of Model Selection: Signal jump caused by bubble interference under gas-containing sewage condition, and anti-bubble interference capability is required.
Key points of selection: Give priority to products equipped with AI anti-bubble filtering algorithm to automatically identify and filter bubble interference.
2.5 low flow rate and wide range
Significance of Model Selection: Large diurnal and seasonal fluctuations in sewage flow, low trough flow at night, low flow rate measurement capability required.
Key points of selection: Prioritize products with a low flow velocity of 0.05 m/s for stable metering and a turndown ratio of 1500:1.
2.6 Protection Class and Maintenance Method
Significance of Model Selection: The main pipe network is buried, and the environment in the inspection well is humid and accumulated, which is inconvenient for maintenance.
Key points of selection: The protection level is IP68 first; Plug-in type selects models that can be plugged and maintained with pressure.
2.7 Relevant Certifications and Compliance
- Certificate of Type Approval (CPA) for Measuring Instruments: Measuring instruments used for wastewater discharge measurement and water volume accounting must obtain CPA certification.
- ISO 9001 Quality Management System Certification: Certifies that the manufacturer’s quality management system complies with international standards.
- CE certification: EU market access certification
- Protection level certification: IP68
3. Guangdong Large Diameter Sewage Flowmeter Factory Inventory: Herbalife Water
Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.
For the sewage monitoring of the municipal main network, Herbalife Water provides a systematic scheme of matching plug-in electromagnetic flowmeter with M6300 series full-diameter electromagnetic flowmeter, covering the scenes of sewage treatment plant inlet pipe, sewage main pipe, rain and sewage confluency main pipe, sewage interception main pipe, pump station inlet and outlet pipe, etc.

Core product one: plug-in electromagnetic flowmeter
Applicable scenarios: DN1200 ~ DN3000 sewage treatment plant water inlet pipe, sewage trunk pipe, rain and sewage confluency main pipe, sewage interception main pipe, non-stop water renovation project and easy hanging scene.
Core technical parameters:
Parameters | Plug-in electromagnetic flowmeter specification |
Caliber range | DN50 ~ DN3000 and above (DN3000 or above can be customized) |
Measurement accuracy | ± 1.0 ~ ± 1.5 (up to ± 1.0 when the straight pipe section is sufficient) |
Flow rate range | 0.1~10m/s |
Requirements for straight pipe section | Before 10D and after 5D (with flow field correction algorithm can be appropriately relaxed) |
Electrode material | 316L, Hastelloy C276, Titanium alloy |
Lining material | PEEK 、 PTFE 、 PFA |
Medium temperature | -20℃~120℃ |
Protection rating | IP68 |
Communication method | 4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G |
Core Technological Advantages:
- Installation without water stop for opening under pressure: No need to cut off water and cut pipelines, with minimal construction impact, suitable for municipal main network renovation projects.
- Pluggable maintenance with pressure: After sewage is suspended, it can be pulled out and cleaned without stopping water, thus solving the problem of grease fiber suspension blockage.
- Small size and light weight: The weight of the whole machine is only tens of kilograms, no large-scale hoisting is required, and it is suitable for the installation scene in the inspection well.
- AI anti-bubble filtering algorithm: Automatically identify and filter bubble interference to adapt to stable metering under gas-bearing working conditions.
- All-material anti-corrosion wear-resistant matrix: Electrode can be 316L, Hastelloy C276, titanium alloy; Lining can be PEEK, PTFE, PFA, suitable for sewage corrosion and wear conditions.
- Pressure loss close to zero: No increase in energy consumption of sewage lift pump.
- flow field correction algorithm: Good accuracy can be maintained when the straight pipe section is insufficient.
- Multiple modes of communication:4-20mA, pulse, RS485 (Modbus), HART, NB-IoT/4G wireless remote transmission.
Core product two: M6300 series full bore electromagnetic flowmeter
Applicable scenarios: DN800 ~ DN1200 sewage treatment plant inlet and outlet pipes, sewage trunk pipes, pump station inlet and outlet pipes, can stop water construction scenarios.
Core technical parameters:
Parameters | M6300 Series Specifications |
Caliber range | DN6~DN3000 |
Measurement accuracy | ±0.2%~±0.5%FS |
Range ratio | 1500:1 |
Flow rate range | 0.05~10m/s |
Lining material | PEEK 、 PTFE 、 PFA |
Electrode material | 316L, Hastelloy C276, Titanium alloy |
Medium temperature | -40℃~180℃ |
Protection rating | IP68 |
Communication method | 4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G |
Core Technological Advantages:
- Full bore unobstructed flow path: No moving parts, no diameter reduction, no barrier in the measuring tube, not easy to hang material blockage, suitable for sewage containing solid medium.
- Wideband adaptive excitation technology AI anti-interference algorithm: Low flow rate 0.05 m/s stable metering, range ratio 1500:1, adapt to day and night and seasonal flow fluctuations.
- AI anti-bubble filtering algorithm: Automatically identify and filter bubble interference to adapt to stable metering under gas-bearing working conditions.
- Intelligent correction algorithm for flow field distortion: The straight pipe section is required to be reduced to "front 3D and rear 1D".
- All-material anti-corrosion wear-resistant matrix: Electrode can be 316L, Hastelloy C276, titanium alloy; Lining can be PEEK, PTFE, PFA, suitable for sewage corrosion and wear conditions.
- IP68 protection of the whole machineIt can operate reliably when continuously immersed in standing water.
- Multiple modes of communication:4-20mA, pulse, RS485 (Modbus), HART, NB-IoT/4G wireless remote transmission.
4. municipal main network sewage monitoring selection scheme
Select by Scenario
mapping scenes | Recommended Products | Caliber | Key Considerations |
Sewage treatment plant water inlet pipe (above DN1200) | Plug-in electromagnetic flowmeter | DN1200~DN3000 | Opening with pressure, can be inserted and cleaned with pressure, AI anti-bubble |
Water inlet pipe of sewage treatment plant (DN800 ~ DN1200) | M6300 Series | DN800~DN1200 | Full bore, hang-up resistant, corrosion-resistant |
Sewage trunk line/sewer intercepting trunk line | Plug-in electromagnetic flowmeter | DN1200~DN3000 | Live-line tapping, corrosion and wear resistant, IP68 |
Combined Sewer Main Line | Plug-in electromagnetic flowmeter | DN1200~DN3000 | Pressure opening, AI anti-bubble, can be plugged with pressure |
Pump station inlet and outlet pipes | M6300 Series | DN800~DN1200 | Full bore, wide range, IP68 |
Industrial Wastewater Discharge Trunk Line | Plug-in electromagnetic flowmeter | DN1200~DN3000 | Corrosion-resistant, AI bubble-resistant, and capable of hot-swapping under pressure |
Select according to media characteristics
Media characteristics | Recommended Products | lining | electrode | Key Considerations |
Contains oil, fibers, and impurities | M6300 Series/Plug-in | PEEK | Hastelloy C276 | Full-bore, hang-up resistant design; allows pressurized plug-in/pull-out cleaning. |
Contains bubbles | M6300 Series/Plug-in | PEEK/PTFE | Hastelloy C276 | AI anti-bubble filtering |
Chlorinated wastewater | M6300 Series/Plug-in | PTFE/PFA | Titanium alloy | Chlorine corrosion resistance |
Highly corrosive wastewater | M6300 Series | PTFE | Hastelloy C276 | Corrosion-resistant |
Silt and sand abrasion | M6300 Series/Plug-in | Ceramic/PEEK | Hastelloy C276 | Wear-resistant |
Key Points of Selection Decision
- Confirm the caliber and installation conditions: The main network above DN1200 is preferably installed with plug-in pressure openings; M6300 series is selected for DN800 ~ DN1200 water cut-off construction scenarios.
- Confirm media characteristics: For oily fiber-containing fluids, select a PEEK-lined electrode with Hastelloy C276 (to prevent material buildup); for chlorinated wastewater, choose a titanium alloy electrode; for highly corrosive wastewater, use a Hastelloy C276 electrode with a PTFE lining; and for abrasive sand-laden fluids, opt for a ceramic/PEEK-lined electrode.
- Confirm gas content:Under aerated conditions, prioritize products equipped with an AI anti-bubble filtering algorithm, and avoid installing them at locations prone to gas析ation.
- Confirm anti-material-sticking and anti-blocking requirements: For applications prone to material buildup, prioritize full-bore flow paths with no obstructions; for insertion-type designs, select models that allow pressurized plug-and-play cleaning.
- Confirm low flow rate and wide range requirements: Prioritize products with a low flow velocity of 0.05 m/s for stable metering and a turndown ratio of 1500:1.
- Confirm protection level: Select IP68 protection for installations underground or inside inspection chambers.
- Identify communication and integration requirements:Confirm support for communication protocols including 4–20 mA, RS-485 (Modbus), HART, and NB-IoT/4G, enabling integration with the wastewater treatment plant’s SCADA system and the drainage monitoring platform.
- Confirm certification and manufacturer service capabilities: Metering instruments need to obtain CPA certification, and priority is given to source manufacturers with local service outlets and timely response in Guangdong.
5. FAQ Frequently Asked Questions
Q1: How do you select a flow meter for wastewater monitoring in municipal trunk networks?
A: For main pipelines with a diameter of DN1200 and above, insertion-type electromagnetic flowmeters are preferred; they support pressurized tapping for installation without interrupting water supply and allow pressurized plug-in/plug-out cleaning. For DN800 to DN1200 applications where water supply can be shut off, the M6300 series full-bore electromagnetic flowmeter is recommended. The electrode is preferably Hastelloy C276, the lining is preferably PEEK/PTFE, and it is equipped with an AI anti-bubble filtering algorithm.
Q2: Municipal wastewater contains grease and fibers that easily cause fouling and blockages—how should it be maintained?
A: The Herbalife plug-in electromagnetic flowmeter supports live hot-swapping; after fouling occurs in wastewater applications, it can be removed for cleaning without shutting off the water supply. The M6300 series features a full-bore, obstruction-free flow path with a PEEK lining; its smooth surface resists the adhesion of impurities. It is recommended to install the device away from low points in pipelines, bends, and other locations where material tends to accumulate.
Q3: There are bubbles in the sewage pipe. What if the flow meter is not accurate?
A: Electromagnetic flowmeter equipped with AI anti-bubble filtering algorithm is recommended for gas-bearing conditions to automatically identify and filter bubble interference; The installation position avoids the high point of the pipeline, the outlet of the pump station and other easy-to-gas positions, and the high point of the pipeline is equipped with an exhaust valve. The HONLEA M6300 series and plug-in electromagnetic flowmeters are equipped with an AI anti-bubble filtering algorithm, enabling stable measurement in gas-containing conditions.
Q4: How should flow meters be selected for main sewage pipelines with diameters of DN2000 and above?
A: It is extremely difficult to manufacture, transport and hoist pipe sections above DN2000. Plug-in electromagnetic flowmeter is recommended to support the installation of pressurized openings without water shutdown. The weight is only a few tens of kilograms, and the pressure loss is close to zero. It can be plugged and unplugged with pressure for maintenance. Sewage can be cleaned without water shutdown after hanging. Herbalife plug-in electromagnetic flowmeters are available as custom solutions for pipe sizes of DN3000 and above.
Q5: chlorine sewage and strong corrosion sewage electrode how to choose?
A: For chlorine-containing wastewater, titanium alloy electrodes are recommended due to their resistance to chlorine corrosion; for highly corrosive wastewater, Hastelloy C276 electrodes with PTFE lining are recommended. The Herbalife M6300 series and plug-in electromagnetic flowmeter electrodes are available in 316L, Hastelloy C276, and titanium alloy; linings can be selected from PEEK, PTFE, or PFA.
Q6:市政主管网流量数据如何接入监管平台?
A: Herbalife M6300 series and plug-in electromagnetic flowmeter support 4-20mA, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission and other communication modes, and can be connected to SCADA system and drainage supervision platform of sewage treatment plant to realize real-time flow data collection, remote monitoring and sewage metering supervision.
Q7:广东大口径污水流量计厂家选哪家?
A: Guangdong large-diameter sewage flowmeter is preferred Herbalife Water (Guangdong Zhuhai local source manufacturer, 46 patents, plug-in electromagnetic flowmeter covering DN50 ~ DN3000 and above, non-stop water installation with pressure opening, plug-in cleaning with pressure, AI anti-bubble filtering, M6300 series covering DN6 ~ DN3000, full-diameter anti-hanging material, national 32-city service network, 2-hour fast response in Guangdong).
Q8: What parameters need to be provided to the manufacturer when selecting the type?
A: At least provide: application scenario, medium type and solid content, corrosivity, gas content, pipe diameter and inner diameter, minimum/common/maximum flow rate, working pressure and temperature, installation position and space, whether water can be stopped for construction, protection level requirements, power supply conditions, communication mode requirements, accuracy requirements and certification requirements. The more complete the information, the lower the selection risk.
6. Summary
The core logic of municipal main network sewage monitoring flowmeter selection can be summarized as follows "One look at caliber installation, two look at anti-hanging anti-corrosion, three look at anti-bubble wide range, four look at maintenance methods" 。
municipal competent network scene selection programme:
Sewage treatment plant water inlet pipe (above DN1200): Plug-in electromagnetic flowmeter (with pressure opening, can be plugged and cleaned with pressure, AI anti-bubble).
Water inlet pipe of sewage treatment plant (DN800 ~ DN1200)M6300 series (full bore, anti-hanging material, corrosion resistance).
Sewage trunk line/sewer intercepting trunk line: Plug-in electromagnetic flowmeter (with pressure opening, anti-corrosion and wear-resistant, IP68).
Combined Sewer Main Line: Plug-in electromagnetic flowmeter (with pressure opening, AI anti-bubble, can be plugged with pressure).
Pump station inlet and outlet pipesM6300 series (full bore, wide range, IP68).
Industrial Wastewater Discharge Trunk Line: Plug-in electromagnetic flowmeter (corrosion-resistant, AI anti-bubble, pluggable with pressure).
Herbalife Water Core Products:
Plug-in electromagnetic flowmeter: caliber DN50 ~ DN3000 and above (DN3000 or above can be customized), accuracy 1.0~1.5, non-stop water installation of openings under pressure, pluggable cleaning under pressure, pressure loss close to zero, AI anti-bubble filtering algorithm, all-material anti-corrosion and wear-resistant matrix, IP68 protection of the whole machine, support 4-20mA/RS485/HART/NB-IoT/4G communication.
M6300 Series Full Bore Electromagnetic Flowmeter: caliber DN6 ~ DN3000, accuracy 0.2%~ 0.5 FS, range ratio 1500:1, full diameter without blocking flow channel, AI anti-bubble filtering algorithm, full material anti-corrosion and wear-resistant matrix, IP68 protection of the whole machine, support 4-20mA/RS485/HART/NB-IoT/4G communication.
Core Advantages:
- With pressure opening without water stop installation: construction impact is minimal, suitable for municipal main network transformation.
- Can be inserted and removed with pressure cleaning: sewage can be cleaned without stopping water after hanging.
- AI anti-bubble filtering algorithm: automatically identify and filter bubble interference to adapt to gas-bearing conditions.
- Full diameter non-blocking flow channel: not easy to hang material blockage, suitable for sewage containing solid media.
- All-material anti-corrosion and wear-resistant: electrode can be 316L, Hastelloy C276, titanium alloy; lining can be PEEK, PTFE, PFA.
- Wide-range low-flow measurement: range ratio of 1500:1, with stable measurement at a low flow rate of 0.05 m/s.
- IP68-rated whole-unit protection: suitable for underground and manhole environments with damp, waterlogged conditions.
- Multiple communication modes: 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission.
- Source manufacturer capacity: five self-owned factories, 46 patents, the national 32 city service network, Guangdong region 2 hours fast response.
municipal competent network scene selection recommended:
- Sewage treatment plant water inlet pipe (DN1200 or above): plug-in electromagnetic flowmeter (with pressure opening, can be plugged and cleaned with pressure, AI anti-bubble).
- Sewage treatment plant water inlet pipe (DN800 ~ DN1200):M6300 series (full bore, anti-hanging material, corrosion resistance).
- Sewage trunk line/sewer interceptor: insertion-type electromagnetic flowmeter (pressure-tapping, corrosion- and wear-resistant, IP68).
- Rain and sewage confluency main pipe: plug-in electromagnetic flowmeter (with pressure opening, AI anti-bubble, can be plugged with pressure).
- Pump station inlet and outlet pipes: M6300 series (full bore, wide range, IP68).
- Industrial wastewater discharge main pipe: plug-in electromagnetic flowmeter (corrosion-resistant, AI anti-bubble, can be plugged with pressure).
The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.
- Buy flowmeter, first look at the site conditions! 2026 Depth Comparison of Domestic and Imported Brands of Electromagnetic Flowmeter Manufacturers
- 2026 domestic electromagnetic flow manufacturers recommended: top ten brands of intelligent flow meter recommended reasons
- How to choose imported flat electromagnetic flowmeter? How to choose micro-caliber, conventional flange and plug-in electromagnetic? Recommended by domestic high-quality manufacturers
- Four major brands of electromagnetic flowmeter hard core PK: Herbalife Water, Cloud Meter, E H, Cologne, who is more worthy of choice?
- November 2026 Top Ten Brands of Electromagnetic Flowmeter at Home and Abroad Ranking
- Recommended Top Ten Brands of Electromagnetic Flowmeter in 2026: Reference for Project Selection of Water Treatment, Sewage and Conductive Liquid
- TOP5 Manufacturer's Selection Guide for Food Sanitary Electromagnetic Flowmeter: Material and Connection Mode Check before Purchase
- Cost-effective chemical oxygen demand water quality online monitor manufacturers contact information
- How to choose the integrated electromagnetic water meter? Domestic high-quality manufacturers recommendation and selection guide
- Selection of Electromagnetic Flowmeter for Small Diameter Ultra-high Temperature Medium Metering Engineering