How to choose electromagnetic flowmeter manufacturers? How to match the flowmeter under the working conditions of bubbles, low flow rate, high temperature and high humidity? Look at the implementation plan of Herbalife Water

2026-10-27 13:47:20

Selection of 1. Electromagnetic Flowmeter: Challenges of Three Special Conditions

Electromagnetic flowmeter is widely used in municipal water supply and drainage, sewage treatment, chemical industry, food, papermaking, AI computing force liquid cooling and other fields. However, in actual operating conditions, three special scenarios are frequently encountered—bubble interference, low-velocity flow measurement, and high-temperature, high-humidity environments—which directly affect measurement accuracy and instrument lifespan. Choosing the right manufacturer and product hinges on evaluating their technical solutions and verifiable capabilities for these three operating conditions.

Special working condition 1: bubble interference

Problem performanceThe raw water pipeline is easy to precipitate bubbles at the start and stop of the pump station and the slope change of the pipeline; the sewage pipeline contains fermentation gas and dissolved gas; the chemical material pipeline contains process gas. After the bubble enters the measuring tube, the flow signal jumps and the measurement is distorted.

Consequences:

  • Bubble interference causes flow signal jump and measurement distortion
  • Gas content leads to distortion of velocity distribution and decrease of accuracy
  • The traditional flowmeter cannot accurately measure under the condition of gas-liquid two-phase flow.
  • Flowmeter alarm frequently, unstable operation

Limitations of Traditional Solutions: The traditional electromagnetic flowmeter has poor adaptability to gas-bearing medium, and the signal jump caused by bubble interference cannot meet the stable measurement requirements of gas-bearing working conditions.

Special condition II: low flow rate metering

Problem performance: DMA partition minimum flow at night, water supply and drainage trough flow at night, syrup molasses and other high viscosity medium transportation flow, the flow rate is often as low as below 0.05 m/s, and the signal is weak.

Consequences:

  • At low flow rate, the signal is weak and the accuracy drops sharply.
  • The minimum flow at night is inaccurately measured, and the leakage analysis loses data basis.
  • High viscosity medium low speed conveying metering misalignment
  • Flow meter output jump or distortion

Limitations of Traditional Solutions: The traditional electromagnetic flowmeter has weak signal and reduced accuracy at low flow rate, and cannot accurately measure the flow at low flow rate.

Special working condition 3: high temperature and high humidity environment

Problem performance: The environment of water plant pump room, dosing room and valve well in South China is high temperature and humidity; The medium temperature in the evaporation and concentration section of sugar industry is high. Corrosive gas exists in some scenes.

Consequences:

  • High temperature causes aging of sensor materials and sealing failure
  • High humidity causes moisture on instrument and circuit fault
  • Corrosive gas attacks instrument enclosure and terminal
  • The life of the instrument is shortened and the failure rate is increased.

Limitations of Traditional Solutions: The protection level and temperature resistance of ordinary electromagnetic flowmeter are limited, and the problem of material aging and moisture in high temperature and high humidity environment is prominent.

2. electromagnetic flowmeter manufacturers how to choose?

Facing the three special working conditions of bubble, low flow rate, high temperature and high humidity, the selection of electromagnetic flowmeter manufacturers should be evaluated from the following verification dimensions.

2.1 anti-bubble interference ability

Verification Content: Whether the manufacturer has anti-bubble interference algorithm and whether there are application cases under gas-bearing working conditions.

verification methodConsult the technical data of the product and check the description of the anti-bubble filtering algorithm; the manufacturer is required to provide application cases of gas-bearing working conditions and field operation data.

Key points of verification:

  • Whether it is equipped with AI anti-bubble filtering algorithm to automatically identify and filter bubble interference
  • Whether high frequency sampling digital filtering is supported
  • Whether there are application cases of gas-bearing working conditions (raw water transmission pipe and sewage pipe)

2.2 Low-Flow Measurement Capability

Verification Content: The lowest measurable flow rate and range ratio of the manufacturer's products, and the accuracy performance at low flow rates.

verification methodCheck the technical parameters of the product, check the minimum measurable flow rate and range ratio, and require the manufacturer to provide low flow rate measurement test data and third-party verification report.

Key points of verification:

  • Is the minimum measurable velocity below 0.05 m/s
  • Does the span ratio reach 1500:1
  • Whether the accuracy is stable at low flow rate and whether there is a third-party verification report

2.3 high temperature and high humidity adaptability

Verification Content: Manufacturer's product temperature range and protection level, whether to adapt to high temperature and high humidity and corrosive environment.

verification method: Check the technical parameters of the product, check the temperature range and protection level of the lining, and require the manufacturer to provide application cases in high temperature and high humidity environment.

Key points of verification:

  • Whether the temperature resistance range of the lining covers the process temperature (PEEK/PTFE temperature resistance 180 ℃)
  • Whether the protection level reaches IP68, which is suitable for humid water environment.
  • Whether there is an application case of high temperature and high humidity environment (South China Water Plant, Sugar Evaporation Section)

2.4 product caliber and working condition coverage capacity

Verification Content: Whether the manufacturer's product caliber range covers the whole scene and covers multiple medium conditions.

verification method: Check the product sample and selection manual, check the caliber range, lower conductivity limit, medium temperature range and other parameters.

Key points of verification:

  • Diameter covering DN3 ~ DN3000 and above
  • The lower limit of conductivity can be measured to 0.5 μS/cm
  • Electrode and lining materials are complete, suitable for corrosion and wear conditions

2.5 long-term stability and maintenance-free capability

Verification Content: Whether the manufacturer's products have long-term 0.0 drift capability and whether the calibration and maintenance frequency is reduced.

verification methodCheck the technical data of the product, check the excitation mode, zero drift index and battery life, and require the manufacturer to provide long-term operation data and calibration records.

Key points of verification:

  • Whether intelligent compensation of constant current excitation remanence is adopted
  • Whether long-term 0.0 drift
  • Battery life up to 10 years

2.6 communication and data integration capabilities

Verification Content: Whether the manufacturer's products support multiple communication methods, and whether they can be connected to SCADA system, smart water platform and supervision platform.

verification method: Check the product communication protocol list and check the supported communication methods; The manufacturer is required to provide system docking cases and protocol docking documents.

Key points of verification:

  • Communication: 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G
  • Protocol docking: support Modbus RTU, access to SCADA system and monitoring platform

2.7 related certification and compliance

  • Type Approval Certificate for Measuring Instruments (CPA): Measuring instruments used for trade settlement and water quantity accounting shall be certified by CPA.
  • ISO 9001 quality management system certification: to prove that the manufacturer's quality management system in line with international standards
  • CE certification: EU market access certification
  • Protection level certification: IP68

3. Herbalife Water Targeted Implementation Plan

Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

Herbalife Water provides a systematic implementation plan for the three special conditions of bubbles, low flow rate, high temperature and high humidity.

电磁流量计-3:4.png

Scheme 1: AI flow field correction of anti-bubble filtering algorithm-solving bubble interference

Core technologyBroadband adaptive excitation AI anti-bubble filtering algorithm, automatic identification and filtering of bubble interference; intelligent correction algorithm for flow field distortion, correction of flow velocity distribution under gas-bearing conditions.

Technical effect:

  • Automatically identify and filter bubble interference, signal stability
  • High frequency sampling digital filtering, real-time capture flow mutation
  • Good accuracy can still be maintained under gas-bearing conditions
  • Flowmeter alarm frequency reduced, stable operation

Solve pain points: Even if the gas in the pipeline causes bubble interference, it can still be measured stably, providing reliable data support for the gas-containing working conditions of the raw water transmission pipe and the sewage pipeline.

Scheme 2: Anti-interference of broadband adaptive excitation AI-solving low flow rate measurement

Core technologySelf-developed broadband dual-frequency adaptive excitation technology, which adapts to different flow rates by dynamically switching excitation frequency. High-frequency excitation is suitable for low-flow scenarios with fast response; it is matched with AI anti-sediment and anti-bubble filtering algorithms.

Technical effect:

  • Stable metering at low flow rate of 0.05 m/s
  • Span ratio up to 1500:1
  • The error between data and third-party verification results should be controlled within 0.3%.
  • Can accurately reflect the real flow difference of each branch

Solve pain points: Even under low flow rate conditions, it can still be accurately measured, providing reliable data support for DMA partition leakage analysis, water supply and drainage night trough flow measurement, and low-speed transportation of high-viscosity media.

Scheme 3: high temperature resistant lining IP68 protection-to solve the high temperature and high humidity environment

Core technology: PEEK/PTFE/PFA high temperature resistant lining, temperature resistant covering -40 ℃ ~ 180 ℃; The whole machine is IP68 protected and can run stably in a water environment for a long time.

Technical effect:

  • PEEK/PTFE lining is temperature resistant to 180 ℃, covering the high temperature section of sugar evaporation concentration and sugar boiling.
  • The whole machine IP68 protection, adapt to the South China water plant pump room, valve well wet water environment
  • Corrosion resistant material, adapt to the corrosive gas environment in the dosing room
  • Long-term stable operation, reduce the failure rate

Solve pain points: Long-term stable operation under high temperature, high humidity and corrosive environment to avoid material aging and moisture failure.

4. Herbalife Water Core Products

Core product: M6300 series full bore electromagnetic flowmeter

Applicable scenarios: municipal water supply and drainage, sewage treatment, chemical industry, papermaking, sugar industry and other medium and large diameter pipelines, gas, low flow rate, high temperature conditions.

Core technical parameters:

Parameters

M6300 Series Specifications

Caliber range

DN6~DN3000

Measurement accuracy

±0.2%~±0.5%FS

Range ratio

1500:1

Flow rate range

0.05~10m/s

Lining material

PEEK 、 PTFE 、 PFA

Electrode material

316L, Hastelloy C276, Titanium alloy

Medium temperature

-40℃~180℃

Protection rating

IP68

Communication method

4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G

Core Technological Advantages:

  1. AI anti-bubble filtering algorithm: Automatically identify and filter bubble interference to adapt to stable metering under gas-bearing working conditions.
  2. Anti-jamming Algorithm AI Broadband Adaptive Excitation Technology: Low flow rate 0.05 m/s stable metering, measuring range ratio 1500:1.
  3. Intelligent correction algorithm for flow field distortion: The straight pipe length requirement is reduced to “3D upstream and 1D downstream,” with correction of the velocity profile under gas-containing operating conditions.
  4. High temperature resistant lining: PEEK/PTFE lining is temperature resistant to 180 ℃, covering high temperature section.
  5. All-material anti-corrosion wear-resistant matrix: Electrode can be 316L, Hastelloy C276, titanium alloy; lining can be PEEK, PTFE, PFA, suitable for corrosion and wear conditions.
  6. IP68 protection of the whole machine: It can run stably in the water environment for a long time and adapt to the high temperature and high humidity environment.
  7. Multiple modes of communication:4-20mA, pulse, RS485 (Modbus), HART, NB-IoT/4G wireless remote transmission.

Core product two: MC6100 series full bore electromagnetic flowmeter

Applicable scenarios: DMA partition entrance, dosing pipeline, sugar industry high viscosity medium, AI calculation force liquid cooling micro-flow monitoring, compact space and low conductivity scenario.

Core technical parameters:

Parameters

MC6100 Series Specifications

Caliber range

DN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32

Minimum flow

3L/h(DN3 up to 1L/h)

Medium flow velocity

0.001~10m/s

Measurement accuracy

Class 0.2, Class 0.3, Class 0.5

Lower limit of conductivity

Measured to 0.5 μS/cm

Electrode material

HC (Hastelloy), 316L, Ta (Tantalum)

Lining material

PEEK, ceramic, PTFE

Medium temperature

Up to 180℃

Protection rating

IP65 (IP68 optional)

Communications

RS485 MODBUS RTU (support HART communication), NB-IoT/4G

Installation Requirements

0D0 (no straight pipe section required)

Core Technological Advantages:

  1. Low-Flow Precision Metering: Broadband adaptive excitation AI anti-interference algorithm, stable measurement at low flow rates of 0.05 m/s, with a minimum measurable flow of 3 L/h (1 L/h for DN3).
  2. AI anti-bubble filtering algorithmAutomatically detects and filters out bubble interference.
  3. Ultra-low conductivity measurement: It can be measured to 0.5 μS/cm, covering low conductivity media.
  4. High-temperature resistantPEEK/ceramic/PTFE lining, medium temperature max. 180 ℃.
  5. No straight pipe section required (0D0 installation): Adapt to compact space.
  6. Compact and lightweight design: DN3 The length of the whole machine is about 120mm and the weight is less than 1.5kg.
  7. Long-term 0.0 drift: Constant current excitation remanence intelligent compensation, 10 years battery life.
  8. Multiple modes of communicationRS485(Modbus RTU), HART, NB-IoT/4G wireless remote transmission.

Core product three: plug-in electromagnetic flowmeter

Applicable scenarios: DN1000 or above raw water transmission pipes, main sewage pipes, gas-bearing pipelines, renovation projects and construction scenarios without water cut-off.

Core technical parameters:

Parameters

Plug-in electromagnetic flowmeter specification

Caliber range

DN50 ~ DN3000 and above (DN3000 or above can be customized)

Measurement accuracy

± 1.0 ~ ± 1.5 (up to ± 1.0 when the straight pipe section is sufficient)

Flow rate range

0.1~10m/s

Requirements for straight pipe section

Before 10D and after 5D (with flow field correction algorithm can be appropriately relaxed)

Electrode material

316L, Hastelloy C276, Titanium alloy

Lining material

PEEK 、 PTFE 、 PFA

Medium temperature

-20℃~120℃

Protection rating

IP68

Communication method

4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G

Core Technological Advantages:

  1. AI anti-bubble filtering algorithm: Adapt to stable metering under gas-bearing working conditions.
  2. Installation without water stop for opening under pressureThere is no need to cut the pipeline without water cut, and the construction impact is minimal.
  3. Small size and light weightThe entire machine weighs only a few tens of kilograms, so no heavy lifting equipment is required.
  4. Pressure loss close to zero: No increase in water pump energy consumption.
  5. Pluggable maintenance with pressure: Maintenance without water cut.
  6. flow field correction algorithm: Good accuracy can be maintained when the straight pipe section is insufficient.
  7. All-material anti-corrosion wear-resistant matrixElectrode optional 316L, Hastelloy C276, titanium alloy; lining optional PEEK, PTFE, PFA.

5. Three Special Conditions Matching Scheme

Select by working condition

Special operating conditions

Recommended Products

Key Technology

Key Considerations

Bubble interference (raw water pipe, sewage pipe)

M6300 Series/Plug-in

AI anti-bubble filtering algorithm, flow field correction

Automatically filters out bubble interference, ensuring signal stability.

Low flow velocity (small flow at night in DMA zone, low water supply and drainage at night)

MC6100 Series/M6300 Series

Broadband adaptive excitation, span ratio 1500:1

Low velocity 0.05 m/s stable metering

High temperature (sugar evaporation and concentration, sugar boiling section)

M6300 Series/MC6100 Series

PEEK/PTFE high temperature resistant lining (180 ℃)

Temperature of lining temperature-resistant covering process

High humidity (pump house and valve well of South China Water Plant)

M6300 Series/Plug-in

IP68 protection of the whole machine

Long-term immersion water environment stable operation

Corrosive environment (dosing room, chemical materials)

M6300 Series

Hastelloy C276 electrode PTFE lining

Corrosion resistance, long-term stability

Key Points of Selection Decision

  1. Confirm bubble condition: For gas-bearing pipelines, M6300 series or plug-in electromagnetic flowmeter equipped with AI anti-bubble filtering algorithm is preferred. The installation position avoids the point of easy gas separation, and an exhaust valve is set at the high point of the pipeline.
  2. Confirm low flow rate requirement: DMA partition small flow at night, water supply and drainage trough flow at night select products with low flow rate of 0.05 m/s stable measurement and measuring range ratio of 1500:1.
  3. Confirm medium temperatureProducts with PEEK/PTFE lining temperature resistance of 180 ℃ are selected for high temperature section; PFA lining is evaluated under ultra-high temperature conditions.
  4. Confirm protection level: Choose IP68 protection for high-temperature, high-humidity environments to suit the damp, waterlogged conditions found in pump houses and valve pits.
  5. Confirm Corrosivity: Corrosive media choose Hastelloy C276 electrode PTFE lining; chlorine-containing media choose titanium alloy electrode.
  6. Confirm the caliber and installation conditions: Plug-in electromagnetic flowmeter is preferred for large-diameter gas-bearing pipelines above DN1000; MC6100 series 0D0 is selected for installation in compact space.
  7. Identify communication and integration requirements: Confirm that it supports 4-20mA, RS485(Modbus), HART, NB-IoT/4G and other communication methods, and connects to SCADA system and supervision platform.
  8. Confirm certification and manufacturer service capabilities: Metering instruments shall be certified by CPA, and manufacturers with local service outlets and timely response shall be preferred.

6. FAQ Frequently Asked Questions

Q1: electromagnetic flowmeter manufacturers how to choose?

A: It is recommended to select an electromagnetic flowmeter manufacturer to evaluate from the verification dimensions: anti-bubble interference capability (AI anti-bubble filtering algorithm, gas-bearing working condition case), low flow rate metering capability (minimum measurable flow rate 0.05 m/s, range ratio 1500:1), high temperature and high humidity adaptability (lining temperature resistance 180 ℃, IP68 protection), product caliber and working condition coverage (DN3 ~ DN3000, conductivity 0.5 μS/cm), long-term stability (constant current excitation residual magnetization intelligent compensation, 10-year battery life), communication and data integration capability (4-20mA/RS485/HART/NB-IoT/4G), certification and compliance (CPA certification, ISO 9001).

Q2: There are bubbles in the pipeline. What if the electromagnetic flow meter is not accurate?

A: Electromagnetic flowmeter equipped with AI anti-bubble filtering algorithm is recommended for gas-bearing conditions to automatically identify and filter bubble interference; The installation position avoids the high point of the pipeline, the outlet of the pump station and other easy-to-gas positions, and the high point of the pipeline is equipped with an exhaust valve. Ensure stable flow rate distribution under straight pipe conditions. Herbalife M6300 series and plug-in electromagnetic flowmeter are equipped with AI anti-bubble filtering algorithm to adapt to stable measurement of gas-bearing conditions.

Q3: Can electromagnetic flowmeter be accurate under low flow rate conditions?

A: Herbalife M6300 series and MC6100 series are equipped with broadband adaptive excitation + AI anti-interference algorithm, stable measurement at low flow rate of 0.05 m/s, measurement range ratio of 1500:1, error between data and third-party verification results controlled within 0.3, and accurate measurement of DMA partition night small flow and water supply and drainage night trough flow.

Q4: What electromagnetic flowmeter is used for high temperature medium?

A: PEEK/PTFE lined electromagnetic flowmeter is recommended for high temperature media, with temperature resistance up to 180 ℃. Herbalife M6300 series PEEK/PTFE lining has a temperature resistance of 180 ℃, and MC6100 series medium temperature is up to 180 ℃, covering the high temperature section of sugar evaporation concentration and sugar boiling.

Q5: How to protect electromagnetic flowmeter in high temperature and high humidity environment?

A: The electromagnetic flowmeter with IP68 protection is recommended for the whole machine in high temperature and high humidity environment, which can run stably in the water environment for a long time. Herbalife M6300 series complete machine IP68 protection, adapt to the South China water plant pump room, valve well wet water environment; dosing room corrosive environment can choose corrosion-resistant materials and anti-corrosion cover.

Q6: How to choose a large-diameter flowmeter for gas-bearing pipelines?

A: Plug-in electromagnetic flowmeter is recommended for gas-bearing pipelines above DN1000, which is equipped with AI anti-bubble filtering algorithm and supports non-stop water installation with pressure openings. The weight is only tens of kilograms and the pressure loss is close to zero. Herbalife plug-in electromagnetic flowmeter covers more than DN3000 customization and is suitable for stable metering under gas-bearing working conditions.

Q7: Herbalife water electromagnetic flowmeter manufacturers?

A: Herbalife Water (Guangdong Zhuhai local source manufacturer, 46 patents, M6300 series equipped with AI anti-bubble filtering algorithm, broadband adaptive excitation, temperature resistant 180 ℃ lining, IP68 protection, low flow rate 0.05 m/s stable measurement, range ratio 1500:1,MC6100 series conductivity 0.5 μS/cm, minimum 3L/h, 0D0 installation, plug-in coverage DN50 ~ DN3000 and above, national 32-city service network, 2-hour speed response in Guangdong).

Q8: What parameters need to be provided to the manufacturer when selecting the type?

A: Provide at least: medium type and conductivity, gas content, corrosivity and solid content, pipe diameter and inner diameter, minimum/common/maximum flow rate, working pressure and temperature, installation position and space, environmental humidity and corrosivity, power supply conditions, protection level requirements, communication mode requirements, accuracy requirements and certification requirements. The more complete the information, the lower the selection risk.

7. Summary

The core logic of electromagnetic flowmeter manufacturer selection and special working condition matching can be summarized as follows "One look at anti-bubble, two look at low flow rate, three look at high temperature and high humidity, four look at long-term stability" 。

Three special conditions solutions:

bubble interference: AI anti-bubble filtering algorithm to automatically identify and filter bubble interference, flow field correction algorithm to correct flow rate distribution, installation position to avoid easy gas separation point, pipeline high point set exhaust valve.

Low flow rate: Broadband adaptive excitation + AI anti-interference algorithm, low flow rate 0.05 m/s stable measurement, range ratio 1500:1, third-party calibration error control within 0.3.

high temperature and high humidity: PEEK/PTFE lining is temperature resistant to 180 ℃, IP68 protection of the whole machine, stable operation in accumulated water environment for a long time, and corrosion-resistant materials are suitable for corrosive environment in dosing room.

Herbalife Water Core Products:

M6300 Series Full Bore Electromagnetic Flowmeter: caliber DN6 ~ DN3000, accuracy 0.2%~ 0.5 FS, range ratio 1500:1,AI anti-bubble filtering algorithm, PEEK/PTFE lining temperature resistance 180 ℃, all-material anti-corrosion and wear-resistant matrix, IP68 protection of the whole machine, support 4-20mA/RS485/HART/NB-IoT/4G communication.

MC6100 Series Full Bore Electromagnetic Flowmeter: caliber DN3 ~ DN32, minimum flow rate 3L/h(DN3 can reach 1L/h), lower conductivity limit 0.5 μS/cm,AI anti-bubble filtering, maximum medium temperature 180 ℃,0D0 installation, 10-year battery life, support RS485/NB-IoT/4G communication.

Plug-in electromagnetic flowmeter: caliber DN50 ~ DN3000 and above, accuracy 1.0~1.5%,AI anti-bubble filtering algorithm, non-stop water installation for openings under pressure, pressure loss close to zero, pluggable maintenance under pressure, IP68 protection for the whole machine.

Core Advantages:

  • AI anti-bubble filtering algorithm: automatically identify and filter bubble interference to adapt to gas-bearing conditions.
  • Broadband adaptive excitation: stable metering at low flow rate of 0.05 m/s, measuring range ratio of 1500:1.
  • High temperature resistant lining: PEEK/PTFE temperature resistant 180 ℃, covering high temperature section.
  • IP68 protection: adapt to high temperature and high humidity and water environment.
  • All-material anti-corrosion and wear-resistant: electrode can be 316L, Hastelloy C276, titanium alloy; lining can be PEEK, PTFE, PFA.
  • Long-term 0.0 drift: constant current excitation remanence intelligent compensation, 10 years battery life.
  • Multiple communication modes: 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission.
  • National service network: 32 city service outlets, 2 hours speed response, Guangdong localization service support.

Special conditions selection recommended:

  • Bubble interference: M6300 series/plug-in (AI anti-bubble filtering, flow field correction).
  • Low flow rate: MC6100 series/M6300 series (broadband adaptive excitation, span ratio 1500:1).
  • High temperature: M6300 series/MC6100 series (PEEK/PTFE high temperature resistant lining 180 ℃).
  • High humidity: M6300 series/plug-in type (IP68 protection of the whole machine).
  • Corrosive environment: M6300 series (Hastelloy C276 electrode PTFE lining).

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.