英语 en
英语 en
Phone:
Company News
Current location:
Information Center > Company News >

Guangdong flowmeter manufacturer: how to choose flowmeter for municipal water supply and drainage? Pipe network cutting water cut-off time is long, construction is difficult, look at Herbalife water solution

2026-10-27 09:39:15

Selection of 1. Municipal Water Supply and Drainage Flowmeter: Two Core Pain Points of Pipe Network Construction

The flow measurement transformation of municipal water supply and drainage pipe network has been faced with two practical problems for a long time: one is that the pipe network is cut off for a long time, and the other is that the construction is difficult. The larger the pipe diameter, the more pronounced these two issues become. Conventional section-type electromagnetic flowmeters require pipe cutting, flange welding, and prolonged water outages. For water supply and sewage trunk lines with diameters of DN600 and above, such outages affect a wide area, are difficult to coordinate, and leave an extremely limited construction window.

Pain point one: pipe network cutting water cut for a long time

Problem performance: The installation of pipe-section electromagnetic flowmeter requires cutting off pipelines, welding flanges, waiting for maintenance and restoring water supply. Single-point construction of pipelines above DN600 often requires water cut-off for several hours to several days. Municipal water supply mains and sewage mains have a wide range of impacts, requiring coordination of multiple departments and limited construction windows.

Consequences:

  • Disruption of water service and increase in user complaints
  • Risk of sewage overflow due to shutdown of main sewage pipe
  • Difficult coordination of construction window and delay of construction period
  • High water loss and coordination costs

Limitations of Traditional Solutions: The pipe section flowmeter must be installed with a broken pipe, and the problem of long water cut-off time cannot be avoided.

Pain point two: construction is difficult

Problem performance: The weight of pipe section electromagnetic flowmeter above DN600 can reach hundreds of kilograms to several tons, and large hoisting equipment is required. Buried pipelines need to excavate working pits, overhead pipelines need to erect scaffolding; Flange welding requires professional welders and flaw detection.

Consequences:

  • It is difficult for large-scale hoisting equipment to enter the site, and it is difficult to construct in remote areas.
  • Large amount of earthwork in excavated working pit, high recovery cost
  • High requirements for welding quality, and increased construction period for flaw detection
  • Construction subject to weather and site conditions

Limitations of Traditional SolutionsThe pipe section flowmeter is large in volume and heavy in weight, and the construction difficulty increases rapidly with the increase of caliber.

2. municipal water supply and drainage flowmeter selection need to pay attention to what?

In addition to accuracy and range, the selection of flowmeter for municipal water supply and drainage should focus on construction adaptability and long-term operation reliability.

2.1 installation mode and impact of water cut-off

Significance of Model Selection: Municipal water supply and drainage pipe network has a wide range of impact, and the installation method directly determines the water cut-off time and construction impact.

Key points of selection: Give priority to products that support pressure opening and non-stop water installation; large-diameter pipeline evaluation plug-in scheme to avoid pipe breakage and cutting.

2.2 construction difficulty and hoisting conditions

Significance of Model SelectionLarge diameter pipe section flowmeter is heavy and requires large hoisting equipment, which makes it difficult to construct in remote areas and buried pipelines.

Key points of selection: Assess equipment weight and hoisting requirements; buried pipelines give priority to lightweight products that do not require large hoisting.

2.3 caliber and flow range

Significance of Model Selection: The municipal water supply and drainage pipe has a large diameter span, and the appropriate diameter shall be selected according to the minimum/common/maximum flow.

Key points of selection: Confirm the range ratio, and give priority to products with a range ratio of 1500:1 to cover day and night flow fluctuations.

2.4 media adaptability

Significance of Model SelectionThe raw water contains sediment and the sewage contains suspended solids and grease. The electrode and lining shall be selected according to the corrosion and abrasion of the medium.

Key points of selectionRaw water contains sand and selects wear-resistant electrode ceramic/PEEK lining; sewage selects Hastelloy C276 electrode PTFE lining; chlorine-containing sewage selects titanium alloy electrode.

2.5 protection level

Significance of Model Selection: The environment of valve well and inspection well is humid and accumulated water, and some scenes are soaked for a long time.

Key points of selection: Protection grade priority IP68.

2.6 Communication and Data Integration

Significance of Model Selection: The monitoring data shall be connected to the water supply dispatching system, the SCADA system of the sewage plant, the intelligent water platform and the water consumption monitoring and metering platform.

Key points of selection: Confirm that it supports 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission and other communication methods.

2.7 related certification and compliance

  • Type Approval Certificate for Measuring Instruments (CPA): Measuring instruments used for trade settlement and water quantity accounting shall be certified by CPA.
  • ISO 9001 quality management system certification: to prove that the manufacturer's quality management system in line with international standards
  • CE certification: EU market access certification
  • Protection level certification: IP68

3. Herbalife Water Targeted Solutions

Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

In view of the pain points of long water cut-off time and difficult construction of municipal water supply and drainage pipe network, Herbalife Water provides three targeted solutions.

电磁流量计-3:4.png

Solution 1: plug-in electromagnetic flowmeter with pressure opening without water stop installation-solve the long water stop time

Core technology: The plug-in electromagnetic flowmeter is inserted into the pipe through the insertion rod to support the installation of the opening under pressure, and there is no need to cut the pipe without stopping water.

Technical effect:

  • The opening under pressure is installed without water cut-off, and the water cut-off time is zero.
  • The construction window is flexible and does not affect the water supply service
  • Suitable for the transformation of water supply main pipe and sewage main pipe above DN1000
  • Avoid the risk of spillover due to the shutdown of the main sewer

Solve pain points: Completely solve the problem of long water cut-off time for pipe network cutting, and minimize the impact of construction on water supply.

Solution two: compact lightweight design-to solve the construction difficulty

Core technology: The weight of the plug-in electromagnetic flowmeter is only tens of kilograms. It can be transported by ordinary vehicles and can be installed manually with small equipment, without large hoisting equipment.

Technical effect:

  • No need for large hoisting equipment, remote areas and buried pipeline construction is convenient
  • Small opening workload, less earthwork, low recovery cost
  • Adapt to installation scenarios in buried and inspection wells
  • Can be plugged and unplugged with pressure for maintenance, and can be cleaned without stopping water after sewage is hung.

Solve pain pointsGreatly reduce the difficulty of large diameter pipeline construction, adapt to remote areas and buried pipeline construction conditions.

Solution 3: 0D0 installation battery-powered wireless remote transmission-to solve the compact space and unattended

Core technology: MC6100 series 0D0 installation does not require front and rear straight pipe sections, 10 years battery life, support NB-IoT/4G wireless remote transmission.

Technical effect:

  • Compact space for DMA partition inlets and pump stations
  • Battery-powered wireless remote transmission, suitable for unattended points
  • Reduce wiring and power supply construction
  • Reduce construction difficulty and maintenance costs

Solve pain points: Solve the problem of compact space installation and unattended point power supply communication.

4. Herbalife Water Core Products

Core product one: plug-in electromagnetic flowmeter

Applicable scenarios: DN600 ~ DN3000 municipal water supply main pipe, sewage main pipe, raw water delivery pipe, pipe network transformation and non-stop water construction scenarios.

Core technical parameters:

Parameters

Plug-in electromagnetic flowmeter specification

Caliber range

DN50 ~ DN3000 and above (DN3000 or above can be customized)

Measurement accuracy

± 1.0 ~ ± 1.5 (up to ± 1.0 when the straight pipe section is sufficient)

Flow rate range

0.1~10m/s

Requirements for straight pipe section

Before 10D and after 5D (with flow field correction algorithm can be appropriately relaxed)

Electrode material

316L, Hastelloy C276, Titanium alloy

Lining material

PEEK 、 PTFE 、 PFA

Medium temperature

-20℃~120℃

Protection rating

IP68

Communication method

4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G

Core Technological Advantages:

  1. Installation without water stop for opening under pressure: No need to cut off the water and cut the pipeline, the construction impact is minimal, suitable for water supply main pipe and sewage main pipe renovation projects.
  2. Small size and light weight: The weight of the whole machine is only tens of kilograms. It can be transported by ordinary vehicles and can be installed manually with small equipment without large hoisting.
  3. Pressure loss close to zero: Only the insert rod partially occupies the pipe section, which does not increase the energy consumption of the pump.
  4. Pluggable maintenance with pressure: Some models support pressure plugging and unplugging, and the sewage can be cleaned and maintained without water cut after hanging.
  5. AI anti-bubble filtering algorithm: Adapt to stable metering under gas-bearing working conditions.
  6. flow field correction algorithm: Built-in flow rate distribution correction algorithm, can still maintain good accuracy when the straight pipe section is insufficient.
  7. All-material anti-corrosion wear-resistant matrix: Electrode can be 316L, Hastelloy C276, titanium alloy; The lining can be PEEK, PTFE and PFA, which is suitable for the corrosion conditions of raw water, sand and sewage.
  8. Multiple modes of communication: Support 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission, access to water supply dispatching system and sewage plant SCADA system.

Core product two: MC6100 series full bore electromagnetic flowmeter

Applicable scenarios: DMA partition entrance, pump station branch pipeline, dosing pipeline, compact space and unattended scene.

Core technical parameters:

Parameters

MC6100 Series Specifications

Caliber range

DN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32

Minimum flow

3L/h(DN3 up to 1L/h)

Medium flow velocity

0.001~10m/s

Measurement accuracy

Class 0.2, Class 0.3, Class 0.5

Lower limit of conductivity

Measured to 0.5 μS/cm

Electrode material

HC (Hastelloy), 316L, Ta (Tantalum)

Lining material

PEEK, ceramic, PTFE

Medium temperature

Up to 180℃

Protection rating

IP65 (IP68 optional)

Communications

RS485 MODBUS RTU (support HART communication), NB-IoT/4G

Installation Requirements

0D0 (no straight pipe section required)

Core Technological Advantages:

  1. No straight pipe section required (0D0 installation): Adapt to DMA partition entrance and pump station compact space, reduce the difficulty of installation and construction.
  2. Battery-powered wireless remote transmission: 10-year battery life, support NB-IoT/4G wireless remote transmission, reduce wiring and power supply construction, suitable for unattended points.
  3. Ultra-low conductivity measurement: It can be measured to 0.5 μS/cm, covering low conductivity media.
  4. Accurate monitoring of small flow: Minimum measurable 3L/h(DN3 up to 1L/h).
  5. Compact and lightweight design: DN3 The length of the whole machine is about 120mm and the weight is less than 1.5kg.
  6. Full bore unobstructed flow path: The pressure loss is close to zero, not easy to block.
  7. Quick response: 40 high-frequency sampling in 1 second to capture sudden flow changes in real time.

Core product three: M6300 series full bore electromagnetic flowmeter

Applicable scenarios: water plant factory pipes, sewage plant inlet and outlet pipes, pump station inlet and outlet pipes, can stop water construction scenarios.

Core technical parameters:

Parameters

M6300 Series Specifications

Caliber range

DN6~DN3000

Measurement accuracy

±0.2%~±0.5%FS

Range ratio

1500:1

Flow rate range

0.05~10m/s

Lining material

PEEK 、 PTFE 、 PFA

Electrode material

316L, Hastelloy C276, Titanium alloy

Medium temperature

-40℃~180℃

Protection rating

IP68

Communication method

4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G

Core Technological Advantages:

  1. High precision metering: ± 0.2%~ ± 0.5%FS accuracy, suitable for trade settlement and factory boundary measurement.
  2. Full bore unobstructed flow path: The pressure loss is close to zero, no blockage, suitable for sewage containing solid media.
  3. Anti-jamming Algorithm AI Broadband Adaptive Excitation Technology: Low flow rate 0.05 m/s stable metering, measuring range ratio 1500:1.
  4. Intelligent correction algorithm for flow field distortionThe straight pipe section requirement is reduced to “3D upstream and 1D downstream.”
  5. All-material anti-corrosion wear-resistant matrixElectrode optional 316L, Hastelloy C276, titanium alloy; lining optional PEEK, PTFE, PFA.
  6. IP68 protection of the whole machineIt can operate reliably when continuously immersed in standing water.

5. municipal water supply and drainage scene selection scheme

Select by Scenario

mapping scenes

Recommended Products

Caliber

Key Considerations

Main water supply pipe (reconstruction)

Plug-in electromagnetic flowmeter

DN600~DN3000

No water stop for opening under pressure, small pressure loss, IP68

Sewage Trunk Line (Renovation)

Plug-in electromagnetic flowmeter

DN600~DN3000

Pressure opening, can be plugged with pressure maintenance, anti-corrosion and wear-resistant

Raw water delivery pipe

Plug-in electromagnetic flowmeter

DN600~DN3000

Pressure opening, wear-resistant electrode, IP68

Plant outlet pipeline (water supply can be shut off)

M6300 Series

DN300~DN1200

High accuracy ±0.2%~±0.5%, IP68

Sewage plant inlet and outlet pipes (water can be stopped)

M6300 Series

DN50~DN1200

Full bore, anti-clogging, corrosion resistance

DMA Partition Entry

MC6100 Series

DN15~DN200

0D0 installation, battery-powered, wireless remote transmission

Branch pipeline of pump station

MC6100 Series

DN15~DN200

0D0 installation, battery-powered, wireless remote transmission

Key Points of Selection Decision

  1. Confirm whether water can be stopped for construction: For the reconstruction of water supply main pipe and sewage main pipe above DN600, plug-in electromagnetic flowmeter shall be installed with pressure opening when water cut-off conditions are not available.
  2. Confirm the specifications and flow range: DN600 ~ DN3000 large diameter pipe to choose plug-in type; DN300 pipe can choose M6300 series or MC6100 series.
  3. Confirm media characteristicsRaw water contains sand and selects wear-resistant electrode ceramic/PEEK lining; sewage selects Hastelloy C276 electrode PTFE lining; chlorine-containing sewage selects titanium alloy electrode.
  4. Confirm construction conditions: Remote areas and buried pipelines give priority to plug-in solutions that are lightweight and do not require large hoisting.
  5. Confirm protection level: Valve well, inspection well environment selection IP68 protection.
  6. Confirm power supply and communication conditions:Unattended locations can be equipped with battery-powered NB-IoT/4G wireless remote transmission.
  7. Identify communication and integration requirements4: Confirm that it supports 4-20mA, RS485(Modbus), HART, NB-IoT/4G and other communication modes, and is connected to water supply dispatching system, SCADA system of sewage plant and water consumption monitoring and metering platform.
  8. Confirm certification and manufacturer service capabilities: Metering instruments need to obtain CPA certification, and priority should be given to manufacturers with local service outlets and timely response in Guangdong.

6. FAQ Frequently Asked Questions

Q1: Municipal water supply main pipe flowmeter installation does not want to stop water how to do?

A: Herbalife plug-in electromagnetic flowmeter is recommended to support installation without water cut-off for opening under pressure, without water cut-off for cutting pipelines, and the water cut-off time is zero. The weight of the whole machine is only tens of kilograms, without large-scale lifting, suitable for DN600 water supply main pipe transformation project.

Q2: How to solve the difficulty in reconstruction and construction of sewage main pipe flowmeter?

A: Herbalife plug-in electromagnetic flowmeter is small in size and light in weight. It can be transported by ordinary vehicles and can be installed manually with small equipment. No large hoisting is required. The opening workload is small, the earthwork volume is small, and the recovery cost is low. It can be plugged and unplugged with pressure for maintenance, and the sewage can be cleaned without stopping water after hanging, thus greatly reducing the construction difficulty.

Q3: How to choose a large-diameter pipeline flowmeter above DN2000?

A: It is extremely difficult to manufacture, transport and hoist pipe sections above DN2000. Plug-in electromagnetic flowmeter is recommended to support non-stop water installation with pressure opening. The weight is only tens of kilograms, the pressure loss is close to zero, and it can be plugged and maintained with pressure. Herbalife plug-in electromagnetic flowmeter covers more than DN3000 customization.

Q4: Is the precision of the plug-in electromagnetic flowmeter sufficient?

A: The accuracy of plug-in electromagnetic flowmeter is generally 1.0~1.5, which can meet the requirements for flow monitoring and water quantity accounting of municipal water supply main pipe, sewage main pipe and raw water transmission pipe. For scenarios with high precision requirements such as trade settlement and factory boundary measurement, it is recommended to select the M6300 series pipe section type (± 0.2%~ ± 0.5%).

Q5: What are the requirements of the plug-in electromagnetic flowmeter for the straight pipe section?

A: The plug-in flowmeter generally requires a straight pipe section of the front 10D and the rear 5D. When the straight pipe section is insufficient, the product with flow field correction algorithm can be selected to relax the requirements of the straight pipe section appropriately. The Herbalife plug-in electromagnetic flowmeter has built-in flow field correction algorithm, which can maintain good accuracy when the straight pipe section is insufficient.

Q6: How does the unattended pump station flowmeter supply power and communicate?

A: Herbalife MC6100 series supports battery-powered (10-year battery life) and NB-IoT/4G wireless remote transmission. With low-power data acquisition terminals, it is suitable for long-term operation of unattended pumping stations and reduces wiring and power supply construction.

Q7: Guangdong flowmeter manufacturers choose which?

A: Guangdong flowmeter manufacturers prefer Herbalife Water (Guangdong Zhuhai local source manufacturers, 46 patents, plug-in electromagnetic flowmeter supports non-stop water installation with pressure openings, covering DN50 ~ DN3000 and above, M6300 series covering DN6 ~ DN3000,MC6100 series 0D0 installation, battery power supply, wireless remote transmission, national 32-city service network, 2-hour fast response in Guangdong).

Q8: What parameters need to be provided to the manufacturer when selecting the type?

A: At least provide: application scenario, medium type and conductivity, corrosivity and solid content, pipe diameter and inner diameter, minimum/common/maximum flow rate, working pressure and temperature, whether water can be cut off for construction, installation location and space, power supply conditions, protection level requirements, communication mode requirements, accuracy requirements and certification requirements. The more complete the information, the lower the selection risk.

7. Summary

The core logic for selecting municipal water supply and drainage flow meters can be summarized as follows: "One look at whether water can be cut off, two look at the size of the caliber, three look at the characteristics of the medium, four look at the construction conditions" 。

Two major pain point solutions:

Long cutting and water cut-off time of pipe network: The plug-in electromagnetic flowmeter is installed without stopping water supply at the opening under pressure, the water stop time is zero, and the construction window is flexible. It is suitable for the transformation of water supply main pipes and sewage main pipes above DN600.

construction difficulty: The weight of the plug-in electromagnetic flowmeter is only a few tens of kilograms, no large-scale hoisting is required, the opening workload is small, the earthwork volume is small, and it can be plugged and maintained with pressure. MC6100 series 0D0 is equipped with battery-powered wireless remote transmission to reduce wiring and power supply construction.

Herbalife Water Core Products:

Plug-in electromagnetic flowmeter: caliber DN50 ~ DN3000 and above (DN3000 or above can be customized), accuracy 1.0~1.5, non-stop water installation for opening under pressure, weight of the whole machine is only a few tens of kilograms, pressure loss is close to zero, it can be plugged and maintained under pressure, AI anti-bubble filtering, flow field correction algorithm, all-material anti-corrosion and wear-resistant matrix, IP68 protection of the whole machine, and supports 4-20mA/RS485/HART/NB-IoT/4G/4G communication. Suitable for renovation projects involving DN600–DN3000 water supply mains, sewage mains, and raw water transmission pipelines.

MC6100 Series Full Bore Electromagnetic Flowmeter: caliber DN3 ~ DN32, minimum flow rate 3L/h(DN3 can reach 1L/h), lower conductivity limit 0.5 μS/cm,0D0 installation, 10-year battery life, support RS485/NB-IoT/4G communication. It is suitable for DMA partition inlet, pump station branch pipeline and dosing pipeline.

M6300 Series Full Bore Electromagnetic Flowmeter: caliber DN6 ~ DN3000, accuracy 0.2~0.5 FS, measuring range ratio 1500:1, full diameter without blocking flow channel, IP68 protection of the whole machine. It is applicable to construction scenarios where water can be cut off, such as water plant factory pipes and sewage plant inlet and outlet pipes.

Core Advantages:

  • Installation without water cut-off for opening under pressure: water cut-off time is zero, and construction impact is minimal.
  • Small size and light weight: the weight of the whole machine is only tens of kilograms, no large-scale lifting is required, and the construction difficulty is greatly reduced.
  • Pressure loss is close to zero: no increase in pump energy consumption.
  • Can be plugged and unplugged with pressure maintenance: sewage can be cleaned without stopping water after hanging.
  • 0D0 installation battery-powered wireless remote transmission: suitable for compact space and unattended points, reducing wiring and power supply construction.
  • All-material anti-corrosion and wear-resistant: electrode can be 316L, Hastelloy C276, titanium alloy; lining can be PEEK, PTFE, PFA.
  • Multiple communication modes: 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission.
  • National service network: 32 city service outlets, 2 hours speed response, Guangdong localization service support.

municipal water supply and drainage scene selection recommended:

  • Water supply main pipe (modification): plug-in electromagnetic flowmeter (with pressure opening without water stop, small pressure loss, IP68).
  • Sewage main pipe (modification): plug-in electromagnetic flowmeter (with pressure opening, can be inserted and pulled with pressure maintenance, anti-corrosion and wear-resistant).
  • Raw water transmission pipe: plug-in electromagnetic flowmeter (with pressure opening, wear-resistant electrode, IP68).
  • Factory pipe of water plant (water can be stopped):M6300 series (high precision ± 0.2%~ ± 0.5%, IP68).
  • Sewage plant inlet and outlet pipes (can stop water):M6300 series (full bore, anti-clogging, corrosion resistance).
  • DMA partition entrance: MC6100 series (0D0 installation, battery power supply, wireless remote transmission).
  • Pump station branch pipeline: MC6100 series (0D0 installation, battery power supply, wireless remote transmission).

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.



Consultation Hotline
Contact via WeChat
Get Quote
Back to top