In the operation of Herbalife Smart Water, the slurry electromagnetic flowmeter is widely used in the measurement of sludge mixture, chemical slurry, slurry and other media, and is the core equipment to ensure the stable operation and precise control of the water system. However, in actual operation and maintenance, staff often encounter various types of confusion such as measurement distortion, equipment failure, selection and adaptation, which affect operation and maintenance efficiency and measurement accuracy.

In order to help Herbalife Smart Water related staff quickly solve practical problems, this article summarizesSelection, installation, operation and maintenance, troubleshootingFor the four major types of high-frequency problems, senior engineers in the industry combine the actual working conditions of Herbalife Smart Water to give accurate and landing solutions. Without complicated theories, puzzles can be quickly solved by comparison to ensure the long-term and accurate operation of the slurry electromagnetic flowmeter.

1. selection type: adapt to Herbalife smart water working conditions, avoid selection errors

Herbalife Smart Water involves sludge treatment, chemical slurry transportation and other scenarios. The slurry has large differences in solid content, corrosivity and viscosity. Improper selection can easily lead to early scrapping of equipment and measurement distortion. The following are the most common selection puzzles and solutions.

Q1: In Herbalife Smart Water, should sludge mixed liquor (solid content 20%-40%) be selected as pipe segment or plug-in slurry electromagnetic flowmeter?

A: PreferredPipe section type slurry electromagnetic flowmeter, insertion-type is not recommended. Herbalife Smart Water's sludge mixed liquor has high solid content, easy sedimentation and high viscosity. The pipe section adopts full section measurement, has no clean dead angle, is not easy to appear sedimentation blockage, and the wear-resistant lining can effectively resist sludge particle erosion. Inserted type only single point measurement, easy to cause measurement distortion due to sludge sedimentation and probe wear, and high maintenance frequency. It is only suitable for large sludge pipelines above DN800 that cannot be shut down for installation, and it is necessary to use wear-resistant probe and increase the maintenance frequency.

Q2: What material should be selected for the chemical slurry (containing acid and alkali components), lining and electrode of Herbalife Smart Water?

A: Combined with the corrosive characteristics of chemical slurry, it is recommended to match as follows, which is suitable for most chemical scenarios of Herbalife Smart Water: ① Lining: polytetrafluoroethylene (PTFE) or perfluorinated ether (FFKM) is preferred, with excellent corrosion resistance, can resist erosion of various acid and alkali media, has no risk of aging and falling off, and is suitable for most chemical slurry; ② Electrode: Hastelloy or titanium alloy is selected, which does not react with acid and alkali slurry to ensure stable metering, avoid signal drift due to electrode corrosion. If the slurry contains a small amount of solid particles (causing slight abrasion), wear-resistant Hastelloy alloy electrodes can be selected to provide both corrosion resistance and abrasion resistance.

Q3: In Herbalife Smart Water, how should the measuring range be set for slurry pipelines with different pipe diameters?

A: The core follows the principle of "measuring range covers the actual flow rate, taking into account anti-precipitation and anti-wear", and is suitable for all kinds of pipe diameter scenarios of Herbalife Smart Water: ① The optimal flow rate range is 0.5-5 m/s to avoid slurry precipitation caused by too low flow rate and aggravating equipment wear; ② Range setting: it is recommended to be 1.2-1.5 times of the actual maximum flow rate on site; ③ Special scene: for sludge mixed liquor and high viscosity slurry with solid content> 30%, the measuring range can be appropriately enlarged to 1.5 times to ensure accurate measurement. DN50-DN300 small and medium-sized pipe diameter (such as chemical slurry branch pipe), the measuring range can be slightly compact (1.2 times), and the measuring range can be appropriately relaxed (1.5 times) for large pipe diameter above DN500 (such as main sludge pipe).

Q4: Herbalife Smart Water uses slurry electromagnetic flowmeter. Is it necessary to have self-cleaning function?

A: Select by scene, focusing on the characteristics of easy scaling and precipitation of slurry: ① Required scene: scenes that are easy to scale and precipitate such as sludge mixed liquor and high viscosity starch slurry (such as Herbalife sludge treatment link), and flowmeter with ultrasonic self-cleaning or mechanical self-cleaning function is preferred, which can automatically remove scaling and precipitation of probe and lining, reduce manual maintenance frequency and avoid blockage; ② Optional scene: chemical slurry with high cleanliness (no obvious scaling and low solid content) can be used without self-cleaning function to reduce procurement cost, but it needs regular manual cleaning.

2. installation category: standard installation to avoid late measurement and hidden trouble

Some pipelines of Herbalife Smart Water are old and renovated pipelines, with limited installation space and complicated working conditions. Unstandard installation can easily lead to measurement distortion, equipment leakage and other problems. The following are the answers to high-frequency installation puzzles.

Q1: Herbalife Smart Water's old pipeline cannot be shut down. Can we install a slurry electromagnetic flowmeter?

A: can be installed, but need to choosePlug-in slurry electromagnetic flowmeter(Only suitable for large pipe diameters above DN500), and adopt non-stop installation technology: first, open holes in the side wall of the pipeline, weld the base, and insert the probe after the base is cooled. There is no need to cut off the pipeline and stop the machine in the whole process, which is suitable for the continuous operation requirements of Herbalife's old pipeline renovation. Note: The plug-in type is only suitable for rough metering scenarios (e. g. sludge discharge statistics). If accurate metering is required (e. g. chemical slurry batching), it is recommended to replace it with a pipe section flowmeter during planned shutdown.

Q2: When installing the slurry electromagnetic flowmeter, what are the requirements for the straight pipe section? How to deal with the Herbalife Smart Water part of the pipeline near the elbow and valve?

A:① Requirements for conventional straight pipe sections: straight pipe sections with upstream ≥ 5 times pipe diameter and downstream ≥ 3 times pipe sections; Plug-in straight pipe sections with upstream ≥ 10 times pipe diameter and downstream ≥ 5 times pipe diameter to avoid measurement distortion caused by flow interference; ② Special treatment (common for old Herbalife pipelines): If the installation position is close to elbows and valves and cannot meet the requirements of straight pipe sections, two schemes can be adopted: first, try to stay away from interference sources; Second, the slurry electromagnetic flowmeter with flow state correction function is selected, which can automatically correct the error caused by uneven flow state and adapt to the installation scene with limited space.

Q3: There is vibration in the slurry pipeline of Herbalife Smart Water. What should I pay attention to when installing the slurry electromagnetic flowmeter?

A: Vibration will cause signal drift of flowmeter and probe loosening. Two precautions shall be taken: ① Shock-proof bracket shall be selected during installation to fix the flowmeter firmly to prevent pipeline vibration from being transmitted to the flowmeter body; ② Slurry electromagnetic flowmeter with anti-vibration function shall be selected, and pipe section type shall be preferred (plug-in probe is easy to cause measurement distortion due to vibration deviation), and flange sealing shall be ensured tightly to avoid slurry leakage. In addition, the installation position as far as possible to avoid the pump body, fan and other vibration sources, the distance from the vibration source ≥ 1.5 meters.

Q4: When installing the slurry electromagnetic flowmeter, is there any requirement for the electrode direction? It is suitable for the scene of Herbalife sludge mixed liquor.

A: There are clear requirements. The core is to "prevent the electrode from being covered by sedimentation", which is suitable for the easy sedimentation characteristics of Herbalife sludge mixed liquor: ① When installed horizontally, the electrode should be vertically upward or at an angle of 45 ° with the vertical direction, so as to prevent the electrode from being covered by sludge sedimentation and cause signal interruption; ② When installed vertically, the slurry should flow from top to bottom to ensure that the electrode can fully contact the slurry, precipitation at the electrodes is also avoided. After installation, check the electrode position to ensure there is no displacement or obstruction.

电磁流量计.jpg

3. operation and maintenance category: daily maintenance, extend the life of equipment, to ensure accurate measurement.

Herbalife Smart Water Slurry Electromagnetic Flowmeter has complex operating environment, high slurry solid content, easy to wear and scale, and equipment failure is easily caused by inadequate daily operation and maintenance. The following are the answers to high-frequency operation and maintenance puzzles.

Q1: How to determine the daily cleaning frequency of Herbalife Smart Water's slurry electromagnetic flowmeter?

A: According to the characteristics of the slurry, the core is to "avoid scaling and clogging". Specific frequency reference: ① Scenarios with high solid content and easy scaling (such as sludge mixed liquor and high viscosity slurry): clean once a week, focus on cleaning the scaling and residual slurry of probe and lining, rinse with clear water, and clean corrosive slurry with neutral detergent; ② Clean and low solid content scenes (such as cleaning chemical slurry): clean once every 2-3 weeks; ③ Special circumstances: If the flowmeter is found to show large fluctuations and errors exceed the standard, clean it immediately and check for scaling and blockage.

Q2: How long is the calibration cycle of the slurry electromagnetic flowmeter? How should Herbalife Smart Water carry out the calibration work?

A: The calibration cycle is determined in combination with the working conditions to meet the requirements of Herbalife Smart Water: ① Conventional cycle: calibration once every 3 months to ensure the measurement accuracy reaches the standard; ② Special scenes: scenes with high solid content and strong wear (such as sludge mixed liquor and slurry) shall be shortened to once a month; ③ Calibration method: Standard volume tube or portable ultrasonic flowmeter can be used for on-site calibration, you can also contact flowmeter manufacturers (such as Dalian Ister and Siemens) for on-site calibration. After calibration, you need to record the data and form a calibration report to ensure compliance with Herbalife Smart Water Metering Standards.

Q3: How to deal with the lining wear of the slurry electromagnetic flowmeter in Herbalife Smart Water? Is it necessary to replace the equipment?

A: There is no need to directly replace the equipment, and it shall be treated according to the degree of wear: ① Slight wear (no damage and no influence on measurement): strengthen cleaning and maintenance, shorten the cleaning period, avoid aggravation of wear, and adjust the flow rate (controlled at 0.5-5 m/s) to reduce slurry erosion; ② Moderate wear (local damage and slight measurement error exceeding the standard): contact the manufacturer to replace the lining without replacing the entire flowmeter, calibrate after replacement to ensure accurate measurement; ③ Severe wear (large area of lining falling off, probe wear): If the service life of the equipment exceeds 5 years, it is recommended to replace a new slurry electromagnetic flowmeter. If the service life is short, the lining and probe can be replaced to reduce operation and maintenance costs.

Q4: What preparations should be made before reusing the slurry electromagnetic flowmeter that has been deactivated for a long time?

A: Focus on "cleaning, inspection and calibration" to avoid failures after activation: ① Cleaning: thoroughly flush the flowmeter pipe, probe and lining with clear water to remove residual slurry and scaling. Corrosive slurry needs to be cleaned with neutral detergent and dried before activation; ② Inspection: Check whether the lining and probe are worn and damaged, whether the electrode is scaled and blocked, whether the flange is tightly sealed, and whether the circuit is in good condition; ③ Calibration: Calibrate with a standard flowmeter before use to ensure that the measurement accuracy is up to the standard. At the same time, debug the equipment parameters, adapt to the current slurry condition, and put it into use after it is correct.

4. Troubleshooting Class: Quickly locate faults, efficiently resolve them, and reduce downtime

Herbalife Smart Water has high requirements for continuous operation of equipment. After the failure of the slurry electromagnetic flowmeter, it needs to be quickly investigated and solved. The following are the most common failures and troubleshooting methods. No professional instruments are required and on-site staff can directly operate them.

Q1: Flowmeter has no display or signal. How should I check it?

A: Check according to the order of "from simple to complex" and quickly locate the problem: ① Check the power supply: confirm that the power supply is connected normally and the voltage is stable. If the power supply fails, repair or replace the power supply in time; ② Check the line: check whether the connecting line between the flowmeter and the controller is loose or broken. If the line fails, reconnect or replace the line; ③ Check the electrode: disassemble the flowmeter, check whether the electrode is covered by scaling and precipitation, or whether the electrode is worn or damaged, clean the electrode or replace the electrode; ④ Check the slurry: confirm that the slurry is conductive medium (conductivity ≥ 5 μS/cm). If it is non-conductive slurry, replace other types of flowmeter (such as Coriolis mass flowmeter).

Q2: How to solve the problem of large fluctuations and excessive errors in measurement data?

A: In combination with the working conditions of Herbalife Smart Water, four points are mainly investigated: ① Flow pattern problem: check whether the straight pipe section at the installation position meets the requirements; if the flow pattern is uneven, adjust the installation position or select a flowmeter with flow pattern correction function; ② Slurry problem: check whether the solid content and viscosity of the slurry are stable. If the fluctuation is large, adjust the slurry ratio and ensure the flow rate is within the range of 0.5-5 m/s; ③ Probe problem: check whether the probe is scaled or worn, clean or replace the probe, and calibrate the flowmeter; ④ Interference problem: check whether there are interference sources such as motors and frequency converters on site, adjust the installation position of the flowmeter (away from interference sources ≥ 1.5 meters), or select a flowmeter with anti-interference function.

Q3: Flow meter slurry leakage, how to deal?

A: Stop the machine immediately to avoid aggravation of leakage. Troubleshooting steps: ① Check the flange seal: confirm whether the flange gasket is aging and damaged. If the gasket is defective, replace the gasket and re-tighten the flange; ② Check the pipeline connection: check the connection part between the flowmeter and the pipeline for looseness, and re-tighten the connecting bolt; ③ Check the equipment damage: check whether the flowmeter body and lining are damaged. If the equipment is damaged, stop using it, contact the manufacturer for repair or replacement; ④ Deal with the leaked slurry: Clean up the leaked slurry according to the environmental protection requirements of Herbalife Smart Water to avoid environmental pollution.

Q4: The flowmeter shows "flow rate is zero", but there is actual slurry flow. How should I check it?

A: Focus on investigating three core problems and solve them quickly: ① If the flow rate is too low, check whether the slurry flow rate is lower than 0.5 m/s. If the flow rate is too low, adjust the pipeline valve to increase the flow rate and avoid slurry precipitation; ② Probe blockage: check whether the probe is blocked by precipitation or scaling, clean the probe and restore the signal; ③ Electrode failure: check whether the electrode is worn or damaged, or the electrode is not connected well with the controller, replace the electrode or reconnect the line and calibrate the flowmeter.

5. Herbalife Smart Water Exclusive Reminder

Combined with the actual working conditions of Herbalife Smart Water (multi-sludge, multi-chemical slurry, some old pipelines), engineers give 2 additional exclusive suggestions to help reduce failures and improve operation and maintenance efficiency:

1. Material adaptation suggestion: For the sludge mixture and chemical slurry scenes of Herbalife Smart Water, the slurry electromagnetic flowmeter of "PU/PTFE lining wear-resistant Hastelloy/tungsten carbide electrode" is preferred to adapt to the working conditions of high solid content, strong wear and strong corrosion to prolong the service life of the equipment;

2. Emergency treatment suggestion: If the flowmeter has an emergency failure (such as serious leakage and signal interruption), the flowmeter can be shut down first, the pipeline valve can be closed to avoid affecting the operation of the entire water system, and at the same time, the manufacturer's after-sales service (such as Dalian Ister and Siemens) can be contacted to provide the failure phenomenon, quickly obtain on-site maintenance service and reduce the downtime.

Summary

In Herbalife Smart Water, the core of the selection, installation, operation and maintenance, and troubleshooting of the slurry electromagnetic flowmeter is "adapting to working conditions, standardizing operation, and regular maintenance". The high-frequency problems summarized in this paper cover most practical scenarios of Herbalife Smart Water, and solutions can be quickly found by comparing problems without complex theories.

If you encounter special problems not covered in this article (such as ultra-high pressure and ultra-high solid content slurry metering), you can contact Herbalife Smart Water's exclusive engineer to provide customized solutions in combination with specific working conditions to ensure the accurate and long-term operation of the slurry electromagnetic flowmeter and provide guarantee for the stable operation of Herbalife Smart Water.

If you would like to learn more about flow meters orFlowmeter Selection, can be consultedHerbalifeFlowmeter manufacturersTechnical customer service:139 2699 8050(WeChat ID is the same) Get help.