image.png


Core structure and working mechanism of 1. screw type water meter
      The screw-wing water meter is a flow metering device based on the principle of mechanical rotation. The core structure includes a watch case, a screw wing, a shaft system, a gear transmission mechanism and a counter. Its working logic is that the water flow pushes the screw wing to rotate along the axial direction of the pipeline, and the rotation speed of the screw wing is proportional to the water flow speed. The number of screw wing rotations is converted into the cumulative flow through the gear transmission mechanism, and the reading is finally displayed by the pointer or the word wheel counter. According to the installation method, it can be divided into horizontal screw type and vertical screw type. The horizontal screw type is suitable for large-diameter pipelines, and the vertical screw type is mostly used in small and medium-diameter scenes. With the characteristics of simple structure and low cost, it is widely used in Municipal water supply, industrial water and other fields.

     2. key performance parameters and applicable scenarios
      The nominal diameter range of the screw-wing water meter isDN50-DN400, the span ratio is usually1:20-1:50, suitable for medium and high flow rate flow measurement scenarios, the starting flow threshold is high, generally in.0.05m/sAbove, suitable for small flow measurement requirements are not high scenes. Working pressure rating upPN10-PN16, can adapt to the conventional pressure environment of municipal pipe network, and the working temperature range is-20℃-50℃It can meet the climatic conditions in most areas. In the old community transformation, temporary water metering, cost-sensitive projects, the screw-type water meter is still a common choice.

      Analysis of Common Faults and Causes of 3.
      Poor sensitivity and excessive negative error at minimum flow rate are common faults of screw type water meters, which are mostly caused by inflexible rotation of screw wings, poor coaxiality of shaft system, tight fit between screw wings and bushings or tight meshing of worm and worm gears. The slow running of the water meter may be due to large mechanical resistance, unreasonable spiral angle of the screw wing, wrong gear installation or serious wear of the shaft bushing. Fast running may be due to wrong gear installation, too small screw angle, or the smaller diameter of the pipe in front of the meter than the diameter of the water meter, resulting in a reduced circulation section. The stoppage of the water meter is mostly caused by the screw wing being damaged by stones, wood and other debris, the gear being broken, or the failure of the magnetic steel connection of the dry water meter.

      4. troubleshooting and on-site treatment methods
      For the problem of poor sensitivity, it is necessary to correct the coaxiality of the shaft system, appropriately increase the gap between the screw wing and the bushing, and adjust the meshing gap of the worm and worm wheel; if the meshing is too tight, it can be improved by reducing the worm pitch diameter or increasing the center distance. When the water meter is running slowly, it is necessary to check the mechanical friction point and reduce the resistance, appropriately twist the wing to adjust the helix angle, correct the gear installation error or replace the worn shaft bushing. For fast-moving faults, gear installation shall be corrected according to the standard, screw angle shall be adjusted to increase circulation, and bottleneck of pipeline in front of the meter shall be checked and rectified. If there are faults such as broken wings and damaged gears, the water meter or counter movement needs to be replaced directly, and the counter needs to be replaced if the magnetic steel of the dry water meter fails.

      Key points of daily maintenance and calibration of 5.
      It is necessary to clean the filter before the watch regularly to prevent sundries from entering the watch body and damaging the screw wings and gears. It is recommended to check the clogging of the filter every quarter and clean it. Check the sealing of the water meter every six months to see if the case and joints are leaking. If there is leakage, replace the gasket in time. Accuracy calibration should be carried out once a year, and the measurement error should be detected by professional equipment. If it exceeds the allowable range, the movement should be adjusted or replaced. When restarting after long-term deactivation, it is necessary to slowly open the valve to avoid water flow impact damage to the screw wing and prolong the service life of the water meter.