英语 en
英语 en
Phone:
Industry News
Current location:
Information Center > Industry News >

What are some domestically produced electromagnetic flowmeters? Could you recommend a few with relatively stable quality?

2026-11-17 13:25:34

1. Domestic electromagnetic flowmeters: from "usable" to "stable and easy to use"

Electromagnetic flowmeters are the mainstream instruments for measuring the flow of conductive liquids, widely used in municipal water services, wastewater treatment, industrial water supply and drainage, chemical engineering, food and beverage, papermaking, metallurgy, AI liquid cooling, and other fields. In the past, the high-end market was dominated by imported brands. In recent years, domestic manufacturers have made continuous breakthroughs in core technologies such as excitation technology, anti-interference algorithms, low-conductivity measurement, and corrosion-resistant materials. As a result, domestically produced electromagnetic flowmeters now possess the precision, stability, and operational adaptability to compete on equal footing with imported brands.

Core Advantages of Domestic Electromagnetic Flow Meters

Outstanding value for money:Under equivalent technical specifications, domestically produced electromagnetic flowmeters are significantly less expensive than imported brands, with the price gap being even more pronounced for large-diameter models.

Delivery schedule is controllable:Produced in our own domestic factory, with short lead times and rapid response; production schedules can be coordinated for urgent projects.

Localization Services:Our extensive domestic service network ensures rapid on-site product selection, installation and commissioning, and troubleshooting.

Flexible operating condition adaptationDomestic manufacturers are more familiar with local operating conditions (high-turbidity raw water, highly corrosive industrial wastewater, and low-conductivity media) and can provide tailored solutions.

Strong capabilities in custom non-standard solutions: Can be customized for special operating conditions in terms of port size, material, communication method, and installation method.

2. What are the domestically produced electromagnetic flowmeters?

Domestic electromagnetic flowmeter product lines are typically categorized by nominal diameter, operating conditions, and media type, encompassing the following major product series:

Product TypeCaliber rangeApplicable Scenarios
Miniature-diameter electromagnetic flowmeterDN3~DN32DMA partition inlet, dosing pipeline, food additive, liquid cooling micro flow
pipe section electromagnetic flowmeterDN6~DN3000Municipal water supply and drainage, sewage treatment, industrial water supply and drainage, food and beverage
Plug-in electromagnetic flowmeterDN50 ~ DN3000 and aboveReconstruction of large diameter water supply main pipe, sewage main pipe and raw water transmission pipe
Hygienic electromagnetic flowmeterDN6~DN32Food and beverage syrup, jam, honey and other high viscosity sanitary medium
Explosion-proof electromagnetic flowmeterDN6~DN3000Explosion-proof areas in the chemical and petrochemical industries, etc.
Ultra-High Temperature Electromagnetic FlowmeterDN3~DN3000Heat transfer oil, high temperature reaction material, etc. 180 ℃ ultra-high temperature working condition

3. Recommended domestically produced electromagnetic flowmeters with relatively stable quality: Compaq Water Technology

Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

电磁流量计-3:4.png

3.1 Core Support for Product Quality Stability

Technological Autonomy:Mastering core technologies such as wideband adaptive excitation, AI anti-bubble filtering, flow field correction, and constant-current excitation with intelligent residual magnetism compensation, achieving industry-leading technical performance.

Technical IndicatorsHerbalife LevelStability Value
Measurement accuracy0.2/0.3/0.5, ± 0.2 ~ ± 0.5 FSAccurate measurement, long-term reliability
Range ratio1500:1Covers traffic fluctuations and prevents inaccuracies in low-traffic segments.
Minimum measurable flow rate0.05m/sStable metering under low flow rate conditions
Lower limit of conductivity0.5 μS/cmCovering low conductivity media
Long-term stabilityLong-term 0.0 driftReduced calibration frequency, reliable long-term data
Protection ratingIP68Stable operation in wet water environment
Temperature resistance of lining180℃Stable operation under high temperature conditions

Fully certified: National high-tech enterprises, ISO 9001 quality management system certification, CPA measuring instrument type approval certificate, CE certification, IP68 protection level certification.

Manufacturer’s capabilities at the source: Five major in-house factories with a total area exceeding 100,000㎡; our facilities ensure product consistency and stable batch quality, making them ideal for large-scale deployment.

Well-established service networkWe have service centers in 32 cities nationwide, offer rapid response within 2 hours, and provide support for equipment selection, installation and commissioning, spare parts supply, and operations and maintenance.

3.2 Core Product 1: MC6100 Series Full-Bore Electromagnetic Flowmeter

Applicable scenarios: DMA partition entrance, dosing pipeline, food additive metering, AI calculation force liquid cooling micro-flow monitoring, compact space and low conductivity scenarios.

Core technical parameters:

ParametersMC6100 Series Specifications
Caliber rangeDN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32
Minimum flow3L/h(DN3 up to 1L/h)
Medium flow velocity0.001~10m/s
Measurement accuracyClass 0.2, Class 0.3, Class 0.5
Lower limit of conductivityMeasured to 0.5 μS/cm
Electrode materialHC (Hastelloy), 316L, Ta (Tantalum)
Lining materialPEEK, ceramic, PTFE
Medium temperatureUp to 180℃
Protection ratingIP68
CommunicationsRS485 MODBUS RTU (support HART communication), NB-IoT/4G
Installation Requirements0D0 (no straight pipe section required)
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

Stable quality highlights:Ultra-low conductivity measurement (0.5 μS/cm) covers low-conductivity media; minimum measurable flow rate is 3 L/h (1 L/h for DN3), meeting the needs of micro‑flow monitoring; zero‑length installation requires no straight pipe sections; long-term zero drift stability, 10-year battery life, reducing calibration frequency; IP68 protection, ensuring stable operation in humid environments.

3.3 Core Product 2: M6300 Series Full-Bore Electromagnetic Flowmeter

Applicable scenarios: municipal water supply and drainage, sewage treatment, industrial water supply and drainage, food and beverage conventional media, medium and large diameter pipes.

Core technical parameters:

ParametersM6300 Series Specifications
Caliber rangeDN6~DN3000
Measurement accuracy±0.2%~±0.5%FS
Range ratio1500:1
Flow rate range0.05~10m/s
Lining materialPEEK、PTFE、PFA、陶瓷
Electrode material316L, Hastelloy C276, Titanium alloy, Tungsten carbide
Medium temperature-40℃~180℃
Protection ratingIP68
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

Stable quality highlights:Full-bore, unobstructed flow path with pressure loss close to zero, resistant to clogging; wideband adaptive excitation AI anti-interference algorithm ensures stable measurement at low flow rates as low as 0.05 m/s, with a turndown ratio of 1500:1; AI anti-airbubble filtering algorithm accommodates gas-containing conditions; all-material corrosion- and wear-resistant matrix adapts to various media; the entire unit has IP68 protection; long-term zero-point drift is negligible.

3.4 Core Product Three: MC6730 High-Temperature Sanitary Miniature Electromagnetic Flowmeter

Applicable scenarios: food and beverage syrup, jam, honey, chocolate sauce and other high viscosity medium, high temperature health scene.

Core technical parameters:

ParametersMC6730 Series Specifications
Caliber rangeDN6~DN32
Flow rangeMinimum 0.03 L/hour
Measurement accuracy±0.2%~±0.5%FS
Lining materialPEEK (Food-Grade)
Electrode materialHastelloy C(HC)
Temperature resistance range130 ℃ high temperature disinfection (SIP/CIP)
Protection ratingIP68/IP69K
Health CertificationFDA、3-A、EHEDG

Stable quality highlights: accurate measurement of micro-flow (minimum 0.03L/hour, measuring range ratio 1000:1); Stable high temperature working conditions; Sanitary level is strict and compliant (surface polished to Ra≤ 0.8 μm, meeting FDA, 3-A and EHEDG health standards); Anti-hanging and anti-clogging.

3.5 Core Product Four: Insertion Electromagnetic Flowmeter

Applicable scenarios: water supply main pipes above DN1000, sewage main pipes, raw water pipes, large-diameter transformation and non-stop water construction scenarios.

Core technical parameters:

ParametersPlug-in electromagnetic flowmeter specification
Caliber rangeDN50 ~ DN3000 and above (DN3000 or above can be customized)
Measurement accuracy±1.0%~±1.5%
Flow rate range0.1~10m/s
Electrode material316L, Hastelloy C276, Titanium alloy, Tungsten carbide
Lining materialPEEK 、 PTFE 、 PFA
Protection ratingIP68
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

Stable quality highlights: Installation without stopping water supply for opening under pressure; The weight of the whole machine is only a few tens of kilograms, and large hoisting is not required. The pressure loss is close to zero; Can be plugged and unplugged with pressure for maintenance; AI anti-bubble filtering algorithm; All-material anti-corrosion and wear-resistant matrix; IP68 protection of the whole machine.

3.6 Core Product Five: Ultra-High Temperature Dedicated Electromagnetic Flowmeter

Applicable scenarios: heat transfer oil circulation, high temperature reaction materials, high temperature cleaning fluid and other 180 ℃ ultra-high temperature conditions.

Core technical parameters:

ParametersSpecification of ultra-high temperature electromagnetic flowmeter
Caliber rangeDN3~DN3000
Medium temperatureMaximum 180°C
Minimum flow3L/h(DN3 up to 1L/h)
Measurement accuracyClass 0.2, Class 0.3, Class 0.5
Lining materialPEEK (temperature resistance 180 ℃)/special process PTFE
Protection ratingIP68
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

Stable quality highlightsPEEK lining has a temperature resistance of 180 ℃, which is matched with high temperature electrode sealing structure and sensor thermal isolation design. High temperature temperature compensation and zero point stabilization technology; Precision processing technology ensures measurement accuracy.

Selection Scheme of Domestic Electromagnetic Flowmeter in 4.

Select by application scenario

Application ScenariosRecommended ProductsCaliberKey Considerations
Municipal Water DMA Partition EntranceMC6100 SeriesDN15~DN200Conductivity 0.5 μS/cm, 0D0 installation, battery-powered wireless remote transmission
Municipal water works factory pipeM6300 SeriesDN300~DN1200Accuracy ± 0.2%~ ± 0.5%, IP68
Municipal water sewage main pipe transformationPlug-in electromagnetic flowmeterDN600~DN3000Live-line tapping, corrosion and wear resistant, IP68
Industrial water supply and drainage circulating water main pipeM6300 SeriesDN100~DN1200Anti-bubble, wide range, access to DCS
Industrial waste discharge pipeM6300 Series/Plug-inDN50~DN3000Corrosion resistant, AI bubble resistant, IP68
Food and beverages: milk, juiceM6300 SeriesDN25~DN100Hygienic grade, accuracy ±0.2%~±0.5%
Food and Beverage Syrups and JamsMC6730 SeriesDN6~DN32Minimum 0.03 L/h, temperature resistance up to 130°C, anti-scaling, FDA/3-A/EHEDG compliant
Chemical explosion-proof areaM6300 Series (Explosion-Proof Type)DN6~DN3000Ex d/Ex ia explosion-proof certification, corrosion-resistant
180 ℃ ultra-high temperature mediumUltra-High-Temperature Dedicated Electromagnetic FlowmeterDN3~DN3000PEEK lining with temperature resistance up to 180°C and a thermal isolation design.

Key Points of Selection Decision

  1. Confirm operating condition type:Clearly specify whether the conditions are low conductivity, low flow rate, gas‑containing, solid‑laden, corrosive, high temperature, space‑constrained, large diameter, hygienic, explosion‑proof, or a combination of multiple conditions.

  2. Match products to operating conditions:For low conductivity, choose the MC6100 series (0.5 μS/cm); for low flow rates, choose the MC6100/M6300 series (0.05 m/s, 1500:1); for gas-containing fluids, choose the M6300 series/insertion type (AI anti-bubble); for fluids with solids, choose the M6300 series/insertion type (full bore, wear-resistant liner); for corrosive fluids, choose the M6300 series (Hastelloy C276/titanium alloy electrodes, PTFE/PFA lining); for high temperatures, choose PEEK/PTFE lining (temperature resistance up to 180°C); for compact spaces, choose the MC6100 series (0D0 installation); for large-diameter retrofits, choose the insertion type (live tapping); for sanitary applications, choose the MC6730 series (FDA/3-A/EHEDG); for explosion-proof environments, choose the explosion-proof version of the M6300 series; for ultra-high temperatures, choose a dedicated electromagnetic flowmeter for ultra-high temperatures.

  3. Verification of Technical Specifications: Confirm that the accuracy is 0.2/0.3/0.5, the range ratio is 1500:1, the minimum measurable flow rate is 0.05 m/s, the lower conductivity limit is 0.5 μS/cm, long-term 0.0 drift, IP68 protection, lining temperature resistance is 180 ℃, and the communication mode is complete.

  4. Verification of manufacturer's capability: Confirm that its own factory, research and development team, patented technology and product system cover DN3 ~ DN3000, complete qualification certification (national high-tech enterprise, ISO 9001, CPA, CE, IP68, health certification, explosion-proof certification), service network coverage and rich project cases.

  5. Identify communication and integration requirements: Confirm that it supports 4-20mA, RS485(Modbus), HART, NB-IoT/4G and other communication modes, and connects to DCS system, SCADA system, intelligent water supply platform and supervision platform.

  6. Confirm Certification and Compliance: The measuring instrument shall obtain CPA certification, the food industry shall confirm FDA/3-A/EHEDG certification, the chemical industry shall confirm explosion-proof certification, and the protection grade shall confirm IP68 certification.

  7. Verification of project cases and service capabilities: Check the cases of similar working conditions to confirm that the manufacturer has relevant application experience; Confirm the coverage of local service outlets, response time, installation and commissioning support, spare parts supply and operation and maintenance support.

5. FAQ Frequently Asked Questions

Q1: What domestically produced electromagnetic flowmeters are available?

A: The domestic electromagnetic flowmeter product line is categorized by nominal size, operating conditions, and media type, and primarily includes: miniature electromagnetic flowmeters (DN3–DN32), pipe-section-type electromagnetic flowmeters (DN6–DN3000), insertion-type electromagnetic flowmeters (DN50–DN3000 and larger), sanitary-grade electromagnetic flowmeters (DN6–DN32), explosion-proof electromagnetic flowmeters (DN6–DN3000), and ultra-high-temperature electromagnetic flowmeters (DN3–DN3000). Herbalife Water has established five major product lines—the MC6100 series, M6300 series, MC6730 series, insertion-type electromagnetic flowmeters, and ultra-high-temperature dedicated electromagnetic flowmeters—covering the full diameter range from DN3 to DN3000.

Q2: Which manufacturer of domestically produced electromagnetic flowmeters do you recommend for relatively stable quality?

A: Domestic electromagnetic flowmeter manufacturers with relatively stable quality recommend Herbalife Water (Guangdong Zhuhai local source manufacturers, 46 patents, five major self-owned factories, MC6100 series covering DN3 ~ DN32,M6300 series covering DN6 ~ DN3000,MC6730 series meeting FDA/3-A/EHEDG health standards, plug-in type covering DN50 ~ DN3000 and above, ultra-high temperature special electromagnetic flowmeter temperature 180 ℃,CPA Metrology Qualification, ISO 9001 Certification, CE Certification, IP68 Protection Certification, National 32 City Service Network, 2-hour Fast Response in Guangdong).

Q3: What is the quality stability of domestic electromagnetic flowmeter?

A: The quality stability of domestic electromagnetic flowmeter should be seen in: technical index (precision 0.2/0.3/0.5, range ratio 1500:1. The minimum measurable flow rate is 0.05 m/s, the lower conductivity limit is 0.5 μS/cm, long-term 0.0 drift, IP68 protection, lining temperature resistance is 180 ℃), technical autonomy (core technologies such as excitation technology, anti-bubble algorithm, flow field correction algorithm, etc.), qualification certification (national high-tech enterprises, ISO 9001, CPA, CE, IP68, health certification, explosion-proof certification), production scale (own factories, products consistency), project cases (application cases of similar conditions).

Q4: Can domestic electromagnetic flowmeter with low conductivity medium be measured?

A: Sure. The lower limit of conductivity of Herbalife MC6100 series can be measured to 0.5 μS/cm, covering low conductivity media such as deionized water, softened water and deep treated water. For ultrapure water with conductivity below 0.5 μS/cm, it is recommended to evaluate alternatives.

Q5: How much precision can domestic electromagnetic flowmeter achieve?

A: The accuracy of the domestic electromagnetic flowmeter can reach 0.2/0.3/0.5, the range ratio is 1500:1, the low flow rate is 0.05 m/s stable measurement, and the error between the data and the third-party verification result is controlled within 0.3. Herbalife M6300 series accuracy ± 0.2 ~ ± 0.5 FS,MC6100 series accuracy 0.2/0.3/0.5.

Q6: What are the sanitary certification of domestic electromagnetic flowmeter?

A: The domestic electromagnetic flowmeter in the food and beverage industry needs to obtain FDA certification, 3-A health standard certification and EHEDG certification. Herbalife MC6730 series meets FDA, 3-A and EHEDG hygiene standards. The surface is polished to Ra≤ 0.8 μm and supports CIP/SIP online cleaning.

Q7: How to access the management platform for domestic electromagnetic flowmeter?

A: Herbalife MC6100 series, M6300 series, MC6730 series, plug-in electromagnetic flowmeter and ultra-high temperature special electromagnetic flowmeter support 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission and other communication modes, and can be connected to DCS system, SCADA system, intelligent water supply platform and supervision platform to realize real-time flow data acquisition, remote monitoring and energy consumption assessment.

Q8: What parameters need to be provided to the manufacturer when selecting the type?

A: Provide at least: working condition type, medium type and conductivity, corrosivity and solid content, gas content, viscosity, temperature, pipe diameter and inner diameter, minimum/common/maximum flow rate, working pressure, installation position and space, water shutdown construction, power supply conditions, protection level requirements, communication mode requirements, accuracy requirements and certification requirements. The more complete the information, the lower the selection risk.

6. Summary

The core logic of domestic electromagnetic flowmeter selection can be summarized as follows “First, assess operational suitability; second, review technical specifications; third, evaluate the manufacturer’s capabilities; fourth, examine service case studies.” 。

Domestic electromagnetic flowmeter product portfolio:

Miniature-diameter electromagnetic flowmeter:DN3~DN32, suitable for DMA zone inlets, dosing pipelines, food additives, and liquid-cooled microflows.

pipe section electromagnetic flowmeter:DN6~DN3000, suitable for municipal water supply and drainage, sewage treatment, industrial water supply and drainage, and the food and beverage industry.

Plug-in electromagnetic flowmeter:DN50~DN3000 and above, suitable for the renovation of large-diameter water supply mains, sewage mains, and raw water transmission pipelines.

Hygienic electromagnetic flowmeter:DN6~DN32, suitable for high-viscosity hygienic media such as food and beverage syrups, jams, honey, etc.

Explosion-proof electromagnetic flowmeter:DN6~DN3000, suitable for hazardous areas in the chemical and petrochemical industries.

Ultra-High Temperature Electromagnetic Flowmeter:DN3~DN3000, suitable for ultra-high temperature service up to 180℃, such as heat transfer oil and high-temperature reaction media.

Herbalife Water Core Products:

MC6100 Series Full Bore Electromagnetic Flowmeter: caliber DN3 ~ DN32, minimum flow rate 3L/h(DN3 can reach 1L/h), lower conductivity limit 0.5 μS/cm,0D0 installation, 10-year battery life, long-term 0.0 drift, IP68 protection, CPA measuring instrument type approval certificate, RS485/HART/NB-IoT/4G communication support.

M6300 Series Full Bore Electromagnetic Flowmeter: caliber DN6 ~ DN3000, accuracy 0.2%~ 0.5 FS, measuring range ratio 1500:1, full diameter without blocking flow channel, AI anti-bubble filtering, full material anti-corrosion and wear-resistant matrix, IP68 protection of the whole machine, obtaining CPA measuring instrument type approval certificate, supporting 4-20mA/RS485/HART/NB-IoT/4G communication.

MC6730 High Temperature Sanitary Micro Electromagnetic Flowmeter: caliber DN6 ~ DN32, minimum flow rate 0.03L/hour, accuracy 0.2~0.5 FS,PEEK food sanitary lining + Hastelloy C electrode, temperature resistance 130 ℃, meeting FDA, 3-A, EHEDG health standards, anti-hanging material design, obtaining CPA measuring instrument type approval certificate.

Plug-in electromagnetic flowmeter: caliber DN50 ~ DN3000 and above, accuracy 1.0~1.5, non-stop water installation for opening under pressure, pressure loss close to zero, pluggable maintenance under pressure, AI anti-bubble filtering, IP68 protection of the whole machine, and obtaining CPA measuring instrument type approval certificate.

Ultra-High-Temperature Dedicated Electromagnetic Flowmeter: caliber DN3 ~ DN3000, medium temperature up to 180 ℃,PEEK lining or special process PTFE lining, high temperature resistant electrode sealing structure and sensor thermal isolation design, high temperature temperature temperature compensation and zero point stabilization technology, obtained CPA measuring instrument type approval certificate.

Core Advantages:

  • Full-diameter coverage: DN3 ~ DN3000, covering the entire product line of micro-diameter, pipe section, plug-in, sanitary, explosion-proof and ultra-high temperature.

  • Technical autonomy: broadband adaptive excitation, AI anti-bubble filtering, flow field correction, constant current excitation residual magnetic intelligent compensation and other core technologies.

  • Low conductivity measurement: The MC6100 series can measure up to 0.5 μS/cm.

  • Low flow rate metering: low flow rate 0.05 m/s stable metering, range ratio 1500:1.

  • Long-term 0.0 drift: constant current excitation remanence intelligent compensation, reduce the calibration frequency.

  • All-material anti-corrosion and wear-resistant: electrode can be 316L, Hastelloy C276, titanium alloy, tungsten carbide; lining can be PEEK, PTFE, PFA, ceramic.

  • Hygienic compliance: MC6730 series meets FDA, 3-A, EHEDG hygiene standards, with surface polishing Ra ≤ 0.8 μm.

  • Explosion-proof configurable: Ex d/Ex ia explosion-proof certification optional.

  • Special for ultra-high temperature: temperature resistance 180 ℃,PEEK lining thermal isolation design.

  • No straight pipe section (0D0 installation): suitable for compact space.

  • With pressure opening without water stop installation: large diameter reconstruction project construction impact is minimal.

  • Multiple communication modes: 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission.

  • Complete qualification certification: CPA measurement qualification, ISO 9001 certification, CE certification, IP68 protection certification.

  • Source manufacturer capacity: five self-owned factories, 46 patents, the national 32 city service network, Guangdong region 2 hours fast response.

Recommendations for Selecting Domestic Electromagnetic Flow Meters by Application Scenario:

  • Municipal water DMA partition entrance: MC6100 series (conductivity 0.5 μS/cm, 0D0 installation, battery-powered wireless remote transmission).

  • Factory pipe of municipal water plant: M6300 series (accuracy ± 0.2%~ ± 0.5%, IP68).

  • Reconstruction of municipal water sewage main pipe: plug-in electromagnetic flowmeter (with pressure opening, anti-corrosion and wear-resistant, IP68).

  • Industrial water supply and drainage circulating water main pipe: M6300 series (anti-bubble, wide range, access to DCS).

  • Industrial waste discharge pipe: M6300 series/plug-in type (corrosion-resistant, AI bubble-resistant, IP68).

  • Food and beverage milk juice: M6300 series (sanitary grade, accuracy ± 0.2%~ ± 0.5%).

  • Food and beverage syrup jam: MC6730 series (minimum 0.03L/h, temperature resistance 130 ℃, anti-hanging material, FDA/3-A/EHEDG).

  • Chemical explosion-proof area: M6300 series explosion-proof type (Ex d/Ex ia explosion-proof certification, corrosion resistance).

  • 180 ℃ ultra-high temperature medium: ultra-high temperature special electromagnetic flowmeter (PEEK lining temperature resistance 180 ℃, thermal isolation design).

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.



Consultation Hotline
Contact via WeChat
Get Quote