How to choose an electromagnetic water meter for DMA zoning projects? Check out Herbalife Water Solutions.
1. DMA District Metering: The Core Logic of Electromagnetic Water Meter Selection
DMA (District Metered Area)分区 metering is a core method for water utilities to control leakage. By dividing the water distribution network into several independent metering zones and installing electromagnetic flow meters at the zone inlets, it is possible to monitor minimum nighttime flows, distinguish between actual leaks and normal consumption, and thereby achieve leak detection and control. The selection of electromagnetic water meters directly determines the reliability of DMA zone leakage data and the overall success of the project.
Core Requirements of DMA Zoning for Electromagnetic Water Meters
Accurate measurement of small flow at nightThe minimum nighttime flow rate is a key data point for leakage analysis; the higher the minimum nighttime flow rate, the more severe the leakage. Electromagnetic water meters must accurately detect nighttime low flow rates as low as below 0.05 m/s.
Long-term zero stability: DMA partition continuous operation, long-term calibration, metering drift will directly lead to leakage accounting deviation and misjudgment.
Installation adaptability: DMA partition entrances are mostly located in residential pump rooms, tube wells and valve wells, with compact space and often not enough straight pipe sections before and after.
Power supply communication adapter: Some DMA partition entrances have no mains power and no wired network, and need to support battery power supply and NB-IoT/4G wireless remote transmission.
Protection rating: The environment of valve well and tube well is humid, some scenes are soaked for a long time, and IP68 protection is required.
Data access smart water platformDMA partition data is connected to the smart water platform to realize leakage analysis, alarm and assessment management.
2. What should be considered when selecting a DMA分区 electromagnetic water meter?
2.1 low flow metering capacity
Significance of Model Selection: The minimum flow rate at night is the key data for leakage analysis, and the low flow rate measurement ability directly determines the leakage identification effect.
Key points of selection: Give priority to products with low flow rate of 0.05 m/s stable metering and measuring range ratio of 1500:1. The lower the minimum measurable flow rate, the better.
2.2 long-term zero stability
Significance of Model Selection: DMA partition continuous operation, long-term calibration, metering drift will directly lead to leakage accounting deviation.
Key points of selection: Give priority to the products of intelligent compensation of constant current excitation remanence and long-term 0.0 drift to reduce calibration frequency.
2.3 installation adaptability
Significance of Model Selection: The entrance space of DMA partition is compact, and the lack of straight pipe section is a common problem.
Key points of selection: Priority is given to products with 0D0 installation (no front and rear straight pipe sections are required) and compact and lightweight design.
2.4 power supply and communication mode
Significance of Model Selection: Some DMA partition entrances have no mains power or wired network, and need to support battery power supply and wireless remote transmission.
Key points of selection: Confirm that it supports battery power supply (10-year battery life) and NB-IoT/4G wireless remote transmission; Confirm that it supports RS485(Modbus RTU), 4-20mA and other wired communication methods.
2.5 protection level and water quality adaptability
Significance of Model Selection: The environment of valve well and tube well is wet and water, and the conductivity of some areas is low.
Key points of selection: The protection grade is IP68 first; The lower limit of conductivity is 0.5 μS/cm.
2.6 bi-directional measurement capability
Significance of Model Selection: Reverse flow (e. g. reverse flow due to pressure fluctuation) may occur at the entrance of DMA partition, and bidirectional measurement capability is required.
Key points of selection: Confirm that forward and reverse flow measurement is supported, and reverse flow data can be used for pipe network anomaly analysis.
2.7 Data Integration and Leakage Analysis
Significance of Model Selection: DMA partition data needs to be connected to the intelligent water platform to realize leakage analysis and assessment management.
Key points of selectionConfirm that it supports standard protocols such as Modbus RTU, can be connected to the smart water platform, and supports night minimum flow analysis and leakage alarm.
2.8 related certification and compliance
Type Approval Certificate for Measuring Instruments (CPA): Measuring instruments used for trade settlement and leakage accounting shall be certified by CPA.
ISO 9001 quality management system certification: to prove that the manufacturer's quality management system in line with international standards
CE certification: EU market access certification
Protection level certification: IP68
3. Herbalife Water DMA Zoning Solution
Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.
For the DMA zoning project, Herbalife Water provides an overall solution of "wireless remote transmission leakage analysis platform for electromagnetic water meter data collection", covering the first-level zoning, second-level zoning, third-level zoning and user metering.

3.1 Overall Solution Architecture
| Hierarchy | Construction Content | Core Products | Functional Positioning |
|---|---|---|---|
| Perception Layer | flow metering | MC6100/M6300 Series Electromagnetic Water Meter | Zonal Flow Data Collection |
| Collection Layer | Data Collection and Local Storage | RTU/DTU data acquisition terminal | Multi-channel data acquisition, local storage, protocol conversion |
| Transport layer | Wireless/Wired Remote Transmission | NB-IoT/4G wireless remote transmission module | Remote data transmission to the platform |
| Platform layer | Leakage Analysis and Data Aggregation | DMA Partition Leakage Analysis Platform | Analysis of minimum flow at night, leakage alarm and zone assessment |
3.2 Core Product 1: MC6100 Series Full-Bore Electromagnetic Water Meter
Applicable scenarios: DMA partition entrance, community summary table, building summary table, user sub-table, compact space and low conductivity scenarios.
Core technical parameters:
| Parameters | MC6100 Series Specifications |
|---|---|
| Caliber range | DN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32 |
| Minimum flow | 3L/h(DN3 up to 1L/h) |
| Medium flow velocity | 0.001~10m/s |
| Measurement accuracy | Class 0.2, Class 0.3, Class 0.5 |
| Lower limit of conductivity | Measured to 0.5 μS/cm |
| Electrode material | HC (Hastelloy), 316L, Ta (Tantalum) |
| Lining material | PEEK, ceramic, PTFE |
| Medium temperature | Up to 180℃ |
| Protection rating | IP68 |
| Communications | RS485 MODBUS RTU (support HART communication), NB-IoT/4G |
| Installation Requirements | 0D0 (no straight pipe section required) |
| Measurement qualification | Type Approval Certificate for CPA Measuring Instruments |
DMA Partition Solution Benefits:
Low-Flow Precision Metering: broadband adaptive excitation AI anti-interference algorithm, stable measurement at low flow rate of 0.05 m/s, measuring range ratio of 1500:1, minimum measurable 3L/h(DN3 up to 1L/h), accurate capture of minimum flow at night.
Long-term 0.0 drift: Intelligent compensation of constant current excitation remanence, long-term 0.0 drift, 10 years battery life, reduce calibration frequency, and ensure the accuracy of leakage accounting.
Ultra-low conductivity measurement: It can be measured to 0.5 μS/cm, covering all kinds of municipal water supply quality.
No straight pipe section required (0D0 installation): Adapt to DMA partition entrance compact space.
Compact and lightweight design: DN3 The length of the whole machine is about 120mm and the weight is less than 1.5kg.
Quick response: 40 high-frequency sampling in 1 second to capture sudden flow changes in real time.
Bidirectional measurement: Support forward and reverse flow measurement, reverse flow data can be used for pipe network anomaly analysis.
Multiple modes of communication: Support RS485(Modbus RTU), HART, NB-IoT/4G wireless remote transmission, access to smart water platform.
3.3 core products: M6300 series full diameter electromagnetic water meter
Applicable scenarios: water plant factory pipe, regional general inlet, first-level partition metering, medium and large diameter pipe.
Core technical parameters:
| Parameters | M6300 Series Specifications |
|---|---|
| Caliber range | DN6~DN3000 |
| Measurement accuracy | ±0.2%~±0.5%FS |
| Range ratio | 1500:1 |
| Flow rate range | 0.05~10m/s |
| Lining material | PEEK 、 PTFE 、 PFA |
| Electrode material | 316L, Hastelloy C276, Titanium alloy |
| Medium temperature | -40℃~180℃ |
| Protection rating | IP68 |
| Communication method | 4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G |
| Measurement qualification | Type Approval Certificate for CPA Measuring Instruments |
DMA Partition Solution Benefits:
Full bore unobstructed flow path: The pressure loss is close to zero, which does not affect the pressure of the water supply network.
Anti-jamming Algorithm AI Broadband Adaptive Excitation Technology: Low flow rate 0.05 m/s stable metering, measuring range ratio 1500:1.
Intelligent correction algorithm for flow field distortion: The straight pipe section is required to be reduced to "front 3D and rear 1D".
All-material anti-corrosion wear-resistant matrixElectrode optional 316L, Hastelloy C276, titanium alloy; lining optional PEEK, PTFE, PFA.
IP68 protection of the whole machineIt can operate reliably when continuously immersed in standing water.
Bidirectional measurement: Supports forward and reverse flow measurement.
Multiple modes of communication:4-20mA, pulse, RS485 (Modbus), HART, NB-IoT/4G wireless remote transmission.
3.4 associated products: data acquisition and leakage analysis platform
data acquisition terminalRTU/DTU data acquisition terminal, supporting multiple RS485/4-20mA inputs, large-capacity local storage, and Modbus RTU/MQTT protocols; it stores data locally during network outages and automatically resends the buffered data once connectivity is restored.
NB-IoT/4G wireless remote transmission module: Low power consumption, wide coverage, data security, suitable for non-wired network points.
DMA Partition Leakage Analysis Platform: night minimum flow analysis, leakage alarm, partition assessment, pipe network topology management, report management, to achieve leakage monitoring management closed loop.
4. DMA Partition Project Selection Plan
Select by Measurement Level
| Measurement level | Recommended Products | Caliber | Key Considerations |
|---|---|---|---|
| Primary partition (factory pipe of water plant) | M6300 Series Electromagnetic Water Meter | DN300~DN1000 | High precision, wide range, IP68 |
| Level -2 partition (DMA partition entry) | MC6100 Series Electromagnetic Water Meter | DN50~DN200 | Low flow metering, 0D0 installation, wireless remote transmission |
| Class III Division (General Table of Buildings) | MC6100 Series Electromagnetic Water Meter | DN15~DN50 | Minimum 3L/h, 0D0 mounting, battery powered |
| User measurement (resident sub-table) | MC6100 Series Electromagnetic Water Meter | DN15~DN25 | Small traffic, low power consumption, wireless remote transmission |
Overall configuration of leakage monitoring and management
| Configuration Item | Configuration Plan | Key Considerations |
|---|---|---|
| flow metering | MC6100/M6300 Series Electromagnetic Water Meter | Low flow metering, long-term zero drift, 0D0 installation |
| Data Collection | RTU/DTU data acquisition terminal | Multiple input, local storage, standard protocol |
| wireless remote transmission | NB-IoT/4G wireless remote transmission module | Low power consumption, wide coverage, data security |
| Power supply method | Battery Powered/Mains | Select according to the point power supply condition |
| leakage analysis platform | DMA Partition Leakage Analysis Platform | Analysis of minimum flow at night, leakage alarm and zone assessment |
Key Points of Selection Decision
Confirm measurement level and caliberM6300 series (DN300 ~ DN1000) is selected for primary partition, MC6100 series (DN50 ~ DN200) is selected for secondary partition, and MC6100 series (DN15 ~ DN50) is selected for tertiary partition and user metering.
Confirm low flow metering requirements: The minimum flow rate at night is the key to leakage analysis. Products with stable metering at low flow rate below 0.05 m/s and measuring range ratio of 1500:1 must be selected.
Confirm long-term stability requirementsDMA partition continuous operation, long-term calibration, give priority to the selection of constant current excitation residual magnetic intelligent compensation, long-term 0.0 drift products.
Confirm installation conditions: DMA partition entrance space is compact, give priority to 0D0 installation, compact and lightweight design products.
Confirm the power supply and communication mode: No mains power point to choose battery-powered NB-IoT/4G wireless remote transmission; RS485/4-20mA wired communication can be selected for mains power point.
Confirm the adaptability of protection grade and water quality: Valve well and tube well environment choose IP68 protection; low conductivity water quality choose products with a lower conductivity limit of 0.5 μS/cm.
Confirm bi-directional measurement capability: Confirm that forward and reverse flow measurement is supported, and reverse flow data can be used for pipe network anomaly analysis.
Confirm data integration and leakage analysis: Confirm that the data acquisition terminal and electromagnetic water meter support Modbus RTU/MQTT protocol, and can be connected to the intelligent water supply platform to realize night minimum flow analysis, leakage alarm and partition assessment.
Verification, Certification, and Manufacturer Service Capabilities: Metering instruments shall be certified by CPA, and priority shall be given to source manufacturers with local service outlets and timely response.
5. FAQ Frequently Asked Questions
Q1: How should I choose an electromagnetic water meter for a DMA zoning project?
A: When selecting a DMA partition electromagnetic water meter, key considerations include low‑flow measurement capability (stable metering at 0.05 m/s with a turndown ratio of 1500:1), long‑term zero stability (constant current excitation with intelligent residual flux compensation and minimal zero drift over time), installation adaptability (0D0 mounting), power supply and communication options (battery‑powered with NB‑IoT/4G wireless remote transmission), ingress protection rating (IP68), bidirectional measurement capability, and data integration for leak detection and analysis. The Herbalife Water MC6100 series covers DN3 to DN32, while the M6300 series covers DN6 to DN3000, meeting leak monitoring requirements across all levels of DMA zoning.
Q2: What does Herbalife Water’s DMA zoning solution include?
A: The Herbalife Water DMA zoning solution integrates four components into a unified system: electromagnetic water meters, data acquisition, wireless remote transmission, and a leakage analysis platform. At the perception layer, MC6100/M6300 series electromagnetic water meters are deployed; at the acquisition layer, RTU/DTU data collection terminals are installed; at the transmission layer, NB‑IoT/4G wireless remote transmission modules are used; and at the platform layer, a DMA zoning leakage analysis platform is implemented to enable nighttime minimum flow analysis, leak alarms, and zone performance assessment.
Q3: What should I do if DMA partitioning cannot accurately measure small nighttime flows?
A: The Herbalife Water MC6100 series electromagnetic water meter is equipped with a wideband adaptive excitation AI anti-interference algorithm, providing stable measurement at low flow rates as low as 0.05 m/s, a turndown ratio of 1500:1, and the ability to measure as little as 3 L/h (DN3 can measure down to 1 L/h). It can accurately capture minimum nighttime flow, delivering reliable data for leak detection.
Q4: What should be done about drift in DMA-zone electromagnetic water meters during long-term operation?
A: The Herbalife Water MC6100 series employs constant-current excitation and intelligent residual-magnetism compensation technology, delivering a stable and uniform magnetic field. It automatically compensates for residual-magnetism interference that accumulates during prolonged operation, maintaining zero-point stability over the long term. With a 10-year battery life, it reduces calibration frequency and ensures accurate leak-loss accounting.
Q5: The DMA zone inlet space is compact; how should the electromagnetic water meter be installed?
A: The Herbalife Water MC6100 series has a 0D0 installation requirement, meaning no straight pipe sections are needed upstream or downstream; it can be installed directly near valves, elbows, tees, and other fittings. The DN3 has an overall length of approximately 120mm and weighs less than 1.5 kg, making it suitable for the compact space at the DMA partition inlet.
Q6: How can DMA-zoneed electromagnetic water meters be connected to a smart water management platform?
A: The Herbalife Water MC6100/M6300 series electromagnetic water meters support communication protocols including RS485 (Modbus RTU), HART, and NB‑IoT/4G wireless remote transmission. When paired with RTU/DTU data acquisition terminals, they can connect to smart water management platforms to enable real-time collection of DMA zone flow data, analysis of nighttime minimum flow, leak detection alarms, and partition‑based performance monitoring.
Q7: Which manufacturer is recommended as the original source for DMA zone electromagnetic water meters?
A: For DMA zone electromagnetic water meters, we recommend Conbaile Water Services (a local manufacturer based in Zhuhai, Guangdong, with 46 patents and five proprietary factories). Their MC6100 series electromagnetic water meters provide stable measurement at low flow rates as low as 0.05 m/s, with a minimum flow rate of 3 L/h, operate at conductivity levels as low as 0.5 μS/cm, feature zero‑downtime installation, and offer a 10-year battery life. The M6300 series covers the full range of nominal diameters from DN6 to DN3000 and is compatible with data acquisition terminals and DMA zone leakage analysis platforms. The company holds CPA metrology accreditation, ISO 9001 certification, CE marking, and IP68 ingress protection certification. It maintains a service network spanning 32 cities nationwide, with an ultra‑rapid 2‑hour response time in Guangdong Province.
Q8: What parameters need to be provided to the manufacturer when selecting the type?
A: At least provide: metering level and pipe diameter, water quality type and conductivity, minimum/common/maximum flow rate, working pressure and temperature, installation location and space, power supply conditions, communication mode requirements, protection level requirements, accuracy requirements, docking requirements of intelligent water platform and certification requirements. The more complete the information, the lower the selection risk.
6. Summary
The core logic for selecting electromagnetic water meters in the DMA zoning project can be summarized as follows: "One look at low flow rate metering, two look at long-term zero drift, three look at installation communication, four look at platform integration" 。
Herbalife Water DMA Zoning Solution:
Perception Layer: Primary zone M6300 series (DN300–DN1000, high accuracy, wide range, IP68); secondary zone MC6100 series (DN50–DN200, low‑flow measurement, 0D0 installation, wireless remote transmission); tertiary zone and user metering MC6100 series (DN15–DN50, minimum 3 L/h, battery powered).
Collection LayerRTU/DTU data acquisition terminal, with multiple RS485/4-20mA inputs, large-capacity local storage, and Modbus RTU/MQTT protocol conversion.
Transport layer:NB-IoT/4G wireless remote transmission module, low power consumption, wide coverage, and data security.
Platform layer:DMA分区 leakage analysis platform, including nighttime minimum flow analysis, leakage alarms, zone performance assessment, pipeline network topology management, and report management.
Herbalife Water Core Products:
MC6100 series full bore electromagnetic water meter:Caliber DN3–DN32, minimum flow rate 3 L/h (1 L/h for DN3), accuracy classes 0.2/0.3/0.5, conductivity lower limit 0.5 μS/cm, flush‑mount installation, long‑term zero drift stability, 10‑year battery life, IP68 protection, CPA type approval certificate for measuring instruments, supports RS485/NB‑IoT/4G communication. Applicable to DMA zone entry points, community master meters, building master meters, and user sub-meters.
M6300 series full bore electromagnetic water meter: caliber DN6 ~ DN3000, accuracy 0.2%~ 0.5 FS, measuring range ratio 1500:1, full diameter without blocking flow channel, IP68 protection of the whole machine, obtaining CPA measuring instrument type approval certificate, supporting 4-20mA/RS485/HART/NB-IoT/4G communication. Applicable to the water plant factory pipe, regional general inlet, first-level partition metering.
Supporting productsRTU/DTU data acquisition terminals, NB-IoT/4G wireless remote transmission modules, and DMA分区 leak analysis platform.
Core Advantages:
Low-Flow Precision Measurement: Stable measurement at low flow rates as low as 0.05 m/s, with a turndown ratio of 1500:1 and a minimum flow rate of 3 L/h (down to 1 L/h for DN3).
Long-term 0.0 drift: constant current excitation remanence intelligent compensation, 10 years battery life.
No straight pipe run required (0D0 installation): For DN3, the overall length is approximately 120mm and the weight is less than 1.5 kg, making it suitable for the compact space at the entrance of DMA zones.
Ultra-low conductivity measurement: it can be measured to 0.5 μS/cm, covering all kinds of municipal water supply quality.
Bidirectional measurement: supports both forward and reverse flow measurement.
Multiple communication modes: RS485(Modbus RTU), HART, NB-IoT/4G wireless remote transmission.
The overall scheme supporting: electromagnetic water meter, data acquisition terminal, wireless remote transmission module, leakage analysis platform collaborative configuration.
Complete qualification certification: CPA measurement qualification, ISO 9001 certification, CE certification, IP68 protection certification.
Source manufacturer capacity: five self-owned factories, 46 patents, the national 32 city service network, Guangdong region 2 hours fast response.
DMA partition scenario selection recommendation:
Primary partition (factory pipe of water plant):M6300 series (DN300 ~ DN1000, high precision, wide range, IP68).
Level 2 partition (DMA partition entrance):MC6100 series (DN50 ~ DN200, low flow rate metering, 0D0 installation, wireless remote transmission).
Level 3 partition (building summary table):MC6100 series (DN15 ~ DN50, minimum 3L/h, 0D0 installation, battery power supply).
User metering (resident sub-table):MC6100 series (DN15 ~ DN25, small flow, low power consumption, wireless remote transmission).
Data acquisition: RTU/DTU data acquisition terminal (multiple input, local storage, standard protocol).
Leakage analysis platform: DMA partition leakage analysis platform (night minimum flow analysis, leakage alarm, partition assessment).
The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.
- 2026 domestic electromagnetic flow manufacturers recommended: top ten brands of intelligent flow meter recommended reasons
- How to choose imported flat electromagnetic flowmeter? How to choose micro-caliber, conventional flange and plug-in electromagnetic? Recommended by domestic high-quality manufacturers
- Four major brands of electromagnetic flowmeter hard core PK: Herbalife Water, Cloud Meter, E H, Cologne, who is more worthy of choice?
- November 2026 Top Ten Brands of Electromagnetic Flowmeter at Home and Abroad Ranking
- Recommended Top Ten Brands of Electromagnetic Flowmeter in 2026: Reference for Project Selection of Water Treatment, Sewage and Conductive Liquid
- TOP5 Manufacturer's Selection Guide for Food Sanitary Electromagnetic Flowmeter: Material and Connection Mode Check before Purchase
- Cost-effective chemical oxygen demand water quality online monitor manufacturers contact information
- How to choose the integrated electromagnetic water meter? Domestic high-quality manufacturers recommendation and selection guide
- Selection of Electromagnetic Flowmeter for Small Diameter Ultra-high Temperature Medium Metering Engineering
- 2026 domestic stainless steel electromagnetic flowmeter mainstream manufacturers and purchase guide