Measurement of strong corrosive medium in 1. new energy industry: special working conditions, high selection threshold

The new energy industry covers lithium, photovoltaic, hydrogen energy, energy storage and other fields, and a large number of strong corrosive media are used in the production process. Strongly corrosive media such as hydrofluoric acid, nitric acid, sulfuric acid, hydrochloric acid, phosphoric acid, and sodium hydroxide are widely used in processes including photovoltaic silicon wafer cleaning and etching, lithium‑ion battery cathode material synthesis, hydrogen energy electrolyte preparation, and semiconductor cleaning. Metering of highly corrosive media places extremely stringent demands on the flowmeter’s materials, seals, design, and safety protection.

Typical Working Conditions of Strong Corrosive Medium in New Energy Industry

mediumTypical application scenariosCorrosion characteristicsSpecial risks
Hydrofluoric acid (HF)Photovoltaic silicon wafer cleaning, etching, semiconductor cleaningExtremely corrosive, corroding glass and silicon-containing materialsToxic, strong corrosion, contact with the skin causing serious burns
Nitric acid (HNO3)Photovoltaic silicon wafer cleaning, lithium cathode material dissolution, metal surface treatmentStrong oxidation, strong corrosionCorrosion of metals, toxic gases
Sulfuric acid (H₂ SOH)Lithium electrolyte preparation, battery productionStrong corrosion, strong dehydrationSevere heat release and strong corrosion
Hydrochloric acid (HCl)Photovoltaic silicon wafer cleaning, metal cleaningStrong corrosive, volatileCorrodes metals; volatile gases are irritating.
Phosphoric acid (Hover POK5)Lithium cathode materials, photovoltaic etchingModerately corrosiveCorrosion of metal, easy to scale
Sodium hydroxide (NaOH)Photovoltaic silicon wafer cleaning, lithium battery material preparationStrong alkaline, corrosiveStrong alkali corrosion, easy to crystallize

The core challenge of strong corrosive medium measurement

Material corrosion resistance requirements are extremely high: Hydrofluoric acid corrodes glass and silicon-containing materials, nitric acid strongly oxidizing corrodes metals, and conventional 316L electrodes and PTFE linings are difficult to meet long-term operation requirements.

Safety protection of highly toxic mediumHydrofluoric acid is highly toxic and has a high risk of leakage. The sealing structure of the flowmeter needs to have high reliability to prevent medium leakage.

Microflow measurement: In the preparation of photovoltaic cleaning and lithium-ion materials, the addition amount of strong corrosive medium is small, which requires high-precision measurement of small flow.

High temperature condition: Some strong corrosive media are used at high temperature, and the flowmeter needs to be resistant to high temperature and corrosion.

Explosion-proof requirements: Some media and scenes belong to explosion-proof areas and require explosion-proof certification.

Compact installation space: The internal pipelines of photovoltaic and lithium-ion equipment are dense, and the straight pipe section is insufficient.

Data Integration into the Production Management System: Traffic data needs to be connected to MES system and environmental protection monitoring platform.

2. strong corrosive medium flowmeter selection need to pay attention to what?

2.1 Lining Material Selection

The lining is the key to isolate the medium and the measuring tube body, and the strong corrosive medium has extremely high requirements for the lining material.

Lining materialCorrosion resistance rangeTemperature resistance rangeSuitable for strong corrosive mediumLimitations
PTFE (polytetrafluoroethylene)Strong acid and alkali resistance, oxidant resistance-40℃~180℃Nitric acid, sulfuric acid, hydrochloric acid, phosphoric acid, sodium hydroxideNot resistant to molten alkali metals and fluorine elements
PFA (perfluoroalkoxy resin)Strong acid and alkali resistance, oxidant resistance, temperature resistance slightly higher than PTFE-40℃~150℃Nitric acid, sulfuric acid, hydrochloric acid, phosphoric acid, sodium hydroxideInresistant to fluorine elements
CeramicsStrong acid and alkali resistance, wear resistance-20℃~150℃Nitric acid, sulfuric acid, hydrochloric acid, phosphoric acidNot resistant to hydrofluoric acid and strong alkali
PEEKGeneral corrosion resistance, wear resistance-40℃~180℃Phosphoric acid, sodium hydroxide (dilute)Not resistant to strong oxidizing acid

Peculiarities of hydrofluoric acid: Hydrofluoric acid corrodes glass and silicon-containing materials, PTFE and PFA lining is resistant to hydrofluoric acid corrosion, and is the preferred lining material for hydrofluoric acid metering.

2.2 electrode material selection

Electrode materialCorrosion resistance rangeSuitable for strong corrosive mediumLimitations
Hastelloy C276Resistance to oxidizing and reducing media, nitric acid, sulfuric acid, hydrochloric acidNitric acid, sulfuric acid, hydrochloric acid, phosphoric acidNot resistant to hydrofluoric acid
Tantalum (Ta)Strong acid resistance (except hydrofluoric acid and concentrated sulfuric acid)Nitric acid, hydrochloric acid, sulfuric acid (dilute)Not resistant to hydrofluoric acid, concentrated sulfuric acid, strong alkali
Titanium (Ti)Resistance to oxidation acid and chlorineNitric acid, chlorine-containing mediumNot resistant to reducing acids (hydrochloric acid, sulfuric acid)
Platinum (Pt)Strong acid and alkali resistance, oxidation resistanceNitric acid, sulfuric acid, hydrochloric acid, hydrofluoric acid (part)High cost
Tungsten carbideWear resistance and general corrosion resistanceSolid wear mediumLimited corrosion resistance

Peculiarities of hydrofluoric acidHydrofluoric acid corrodes conventional electrode materials such as Hastelloy C276, tantalum and titanium. Platinum electrode or special hydrofluoric acid-resistant material shall be selected. The applicability of electromagnetic flowmeter under hydrofluoric acid conditions shall be evaluated emphatically.

2.3 measurement principle selection

Measurement principleCorrosion resistance adaptabilityHydrofluoric acid applicabilityNitric acid applicabilityKey Considerations
Electromagnetic flowmeterLining and electrode material optional, corrosion resistantSpecial electrode material (platinum) required, limited applicabilityApplicable (PTFE Lined Hastelloy C276/Tantalum Electrode)Conductive medium applicable
Coriolis mass flow meterLiquid material optional Hastelloy, titanium, PTFEApplicable (Hastelloy/PTFE liquid)ApplicableHigh precision, not limited by conductivity
elliptical gear flowmeterLiquid material optional Hastelloy, PTFEApplicable (Hastelloy/PTFE liquid)ApplicableSuitable for high viscosity clean media
Ultrasonic flow meter (external clamp type)No contact with mediaApplicable (no contact with media)ApplicableNo pressure loss, accuracy affected by pipeline conditions

Peculiarities of hydrofluoric acid: Under hydrofluoric acid conditions, the selection of electromagnetic flowmeter electrodes is limited. Coriolis mass flowmeter, elliptical gear flowmeter, and external clamp ultrasonic flowmeter are safer choices.

2.4 sealing structure and safety protection

Strong corrosive medium, especially hydrofluoric acid, is highly toxic, and the sealing structure needs to have high reliability to prevent leakage of the medium. Products with multiple seal designs, welded seal structures, and fully welded measuring tubes are preferred.

2.5 micro flow measurement

Photovoltaic cleaning and lithium-ion material preparation in the addition of strong corrosive medium is small, priority selection of small flow high-precision metering products.

2.6 explosion-proof requirements

Some media and scenes are explosion-proof areas and require Ex d/Ex ia explosion-proof certification.

2.7 related certification and compliance

  • Type Approval Certificate (CPA) for Measuring Instruments: Instruments used for metrological accounting must obtain CPA certification.

  • ISO 9001 quality management system certification: to prove that the manufacturer's quality management system in line with international standards

  • CE certification: EU market access certification

  • Protection level certification: IP68

  • Explosion-proof certification: Ex d/Ex ia (explosion-proof area)

Recommended by 3. New Energy Industry Strong Corrosive Medium Flowmeter Manufacturers: Herbalife Water

Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

电磁流量计-3:4.png

Ability to 3.1 products with strong corrosive media

Herbalife Water has formed four product lines: M6300 series, MC6100 series, MC6730 series and plug-in electromagnetic flowmeter. It provides PTFE/PFA lined Hastelloy C276/tantalum electrode configuration for strong corrosive media, and provides alternative suggestions for special media such as hydrofluoric acid.

Product lineCaliber rangeStrong corrosive medium applicable scenarioCorrosion resistant configuration
M6300 SeriesDN6~DN3000Nitric acid, sulfuric acid, hydrochloric acid, phosphoric acid, sodium hydroxide and other strong corrosive medium pipelinePTFE/PFA lined Hastelloy C276/Tantalum electrode
MC6100 SeriesDN3~DN32Micro-flow metering and dosing pipeline of strong corrosive mediumPTFE lining, Hastelloy HC/tantalum electrode
MC6730 SeriesDN6~DN32High viscosity strong corrosive medium small flowPEEK Lined Hastelloy C Electrode
Plug-in electromagnetic flowmeterDN50 ~ DN3000 and aboveTransformation of large-diameter discharge main pipe for strong corrosive mediumPTFE/PFA Lined Hastelloy C276/Titanium Alloy Electrode

Material Matching Scheme of 3.2 Strong Corrosive Medium

mediumRecommended ProductsliningelectrodeKey Considerations
Nitric acid (HNO3)M6300 Series/MC6100 SeriesPTFE/PFAHastelloy C276/Tantalumresistance to oxidizing acid
Sulfuric acid (H₂ SOH)M6300 SeriesPTFE/PFAHastelloy C276/TantalumCorrosion resistance (sulfuric acid to be evaluated)
Hydrochloric acid (HCl)M6300 SeriesPTFE/PFATantalum/PlatinumReducing acid resistance
Phosphoric acid (Hover POK5)M6300 SeriesPTFE/PFAHastelloy C276Corrosion-resistant
Sodium hydroxide (NaOH)M6300 Series/MC6100 SeriesPTFE/PFAHastelloy C276/PlatinumStrong alkali resistance
Hydrofluoric acid (HF)Alternative方案——Electromagnetic flowmeter electrode selection is limited, recommended Coriolis mass flowmeter/elliptical gear flowmeter/external clamp type ultrasonic flowmeter

Description of hydrofluoric acid working conditionHydrofluoric acid corrodes glass and silicon-containing materials. Conventional electromagnetic flowmeter electrodes (Hastelloy C276, tantalum, titanium) are not resistant to hydrofluoric acid corrosion. The applicability of electromagnetic flowmeter under hydrofluoric acid conditions needs to be evaluated. It is recommended that Coriolis mass flow meter (Hastelloy/PTFE liquid), elliptical gear flow meter (Hastelloy/PTFE liquid) or external clamp type ultrasonic flow meter (no contact with the medium) is preferred. If it is really necessary to use electromagnetic flowmeter, it is necessary to select platinum electrode PTFE lining and confirm that the manufacturer provides application cases of hydrofluoric acid working conditions.

Core advantage of 3.3 strong corrosive medium

Corrosion-resistant material matrixThe lining can be PTFE and PFA, and the electrode can be Hastelloy C276, tantalum, titanium alloy and platinum. It is suitable for strong corrosive media such as nitric acid, sulfuric acid, hydrochloric acid, phosphoric acid and sodium hydroxide.

Full bore unobstructed flow path: The pressure loss is close to zero, not easy to block, suitable for solid and strong corrosive media.

Microflow measurementMC6100 series minimum measurable 3L/h(DN3 up to 1L/h), suitable for strong corrosive medium micro flow measurement.

Explosion-proof and configurable:Ex d/Ex ia explosion-proof certification, suitable for hazardous areas.

Long-term 0.0 drift: constant current excitation residual magnetic intelligent compensation, reduce the calibration frequency.

IP68 protection of the whole machine: Adapt to the humid environment of new energy factories.

Data Integration: Support 4-20mA, RS485(Modbus), HART, NB-IoT/4G, access to MES system and environmental protection monitoring platform.

Alternative Proposal: For special media such as hydrofluoric acid, provide alternatives to Coriolis mass flowmeter, elliptical gear flowmeter, and external clamp ultrasonic flowmeter.

3.4 Qualifications and Service Capabilities

Qualification Certification: National High-Tech Enterprise, ISO 9001 Quality Management System Certification, CPA Type Approval Certificate for Measuring Instruments, CE Certification, IP68 Protection Rating Certification, and Ex d/Ex ia Explosion-Proof Certification available as options.

Service Network: 32 cities across the country have service outlets, 2-hour fast response, providing selection support, installation and commissioning, spare parts supply and operation and maintenance support. Headquartered in Zhuhai, Guangdong, it enjoys a distinct advantage in providing localized services across the Pearl River Delta region.

Selection Scheme of Strong Corrosive Medium Flowmeter in 4. New Energy Industry

Select by Media

mediumRecommended SchemeliningelectrodeKey Considerations
Nitric acidM6300 Series/MC6100 SeriesPTFE/PFAHastelloy C276/Tantalumresistance to oxidizing acid
Sulfuric acidM6300 SeriesPTFE/PFAHastelloy C276/TantalumCorrosion resistance, concentrated sulfuric acid to be evaluated
hydrochloric acidM6300 SeriesPTFE/PFATantalum/PlatinumReducing acid resistance
Phosphoric acidM6300 SeriesPTFE/PFAHastelloy C276Corrosion-resistant
Sodium hydroxideM6300 Series/MC6100 SeriesPTFE/PFAHastelloy C276/PlatinumStrong alkali resistance
Hydrofluoric acidCoriolis mass flowmeter/oval gear flowmeter/external clamp type ultrasonic flowmeter——Electromagnetic flowmeter electrode selection is limited

Select by application scenario

Application ScenariosRecommended SchemeCaliberKey Considerations
Metering of Etching Solution for Photovoltaic Silicon Wafer CleaningM6300 Series/MC6100 SeriesDN6~DN100PTFE/PFA lined Hastelloy C276/Tantalum electrode, resistant to nitric acid/hydrofluoric acid mixture to be evaluated
Lithium cathode material dissolution measurementM6300 SeriesDN15~DN100PTFE/PFA Lined Hastelloy C276 Electrode, Nitric Acid/Sulfuric Acid Resistant
Lithium electrolyte preparation and measurementM6300 Series (Explosion-Proof Type)DN15~DN100PTFE/PFA Lined Hastelloy C276 Electrode, Ex d/Ex ia Explosion Proof
Hydrogen energy electrolyte preparation and meteringM6300 SeriesDN15~DN100PTFE/PFA lining, Hastelloy C276 electrode, resistant to sodium hydroxide
Strong corrosive medium dosing pipelineMC6100 SeriesDN3~DN32PTFE Lined Hastelloy HC/Tantalum Electrode, min. 3L/h
Transformation of large-diameter discharge main pipe for strong corrosive mediumPlug-in electromagnetic flowmeterDN600~DN3000PTFE/PFA Lined Hastelloy C276/Titanium Alloy Electrode with Presented Openings
Hydrofluoric acid meteringCoriolis mass flow meter/oval gear flow meterDN3~DN50Hastelloy/PTFE wetted parts, not limited by conductivity

Key Considerations in Procurement Decisions

  1. Confirm medium type and concentrationFor highly corrosive media such as nitric acid, sulfuric acid, hydrochloric acid, phosphoric acid, and sodium hydroxide, specify the concentration and temperature, and select a corrosion-resistant material combination.

  2. Confirm special operating conditions for hydrofluoric acid: Electromagnetic flowmeter electrode selection is limited under hydrofluoric acid conditions. Priority is given to evaluating alternatives to Coriolis mass flowmeter, elliptical gear flowmeter or external clamp ultrasonic flowmeter.

  3. Confirm lining material:For highly corrosive media, PTFE/PFA lining is preferred; ensure that the lining’s corrosion resistance range covers the medium.

  4. Confirm electrode material: Hastelloy C276/tantalum electrode is selected by nitric acid; Tantalum/platinum electrode is selected by hydrochloric acid; Hastelloy C276/platinum electrode is selected by sodium hydroxide; Confirm that the corrosion resistance range of the electrode covers the medium.

  5. Identify the sealing structure: Strong corrosive medium, especially highly toxic medium, choose multiple seals or fully welded seal structure to prevent leakage.

  6. Confirm minor flow requirements: Photovoltaic cleaning and lithium battery material preparation strong corrosive medium addition amount is small, select MC6100 series (minimum 3L/h) and other small flow metering products.

  7. Confirm explosion-proof requirements:Select explosion-proof certified products (Ex d/Ex ia) for hazardous areas.

  8. Identify communication and integration requirements:Confirm support for communication protocols including 4–20 mA, RS-485 (Modbus), HART, and NB-IoT/4G, enabling integration with MES systems and environmental monitoring platforms.

  9. Verification of Manufacturer Capabilities and Certifications: Confirm that the manufacturer has corrosion-resistant material matrix, micro-flow measurement capability, sealing structure design capability and explosion-proof certification; The measuring instrument shall obtain CPA certification; Priority shall be given to the source manufacturer with local service outlets and timely response.

  10. ask for similar media application casesThe risk of strong corrosive medium is high, and the manufacturer is required to provide the application case of similar medium and the corrosion resistance description of the material, and conduct the material compatibility test if necessary.

5. FAQ Frequently Asked Questions

Q1: Which is recommended by the manufacturer of strong corrosive medium flowmeter in the new energy industry in 2026?

A: In 2026, the strong corrosive medium flowmeter in the new energy industry recommends Herbalife Water (Guangdong Zhuhai local source manufacturer, 46 patents, five self-owned factories, M6300 series covering DN6 ~ DN3000,PTFE/PFA lined Hastelloy C276/tantalum electrode resistant to strong corrosion, MC6100 series covering DN3 ~ DN32, minimum 3L/h, configurable, CPA metrology qualification, ISO 9001 certification, CE certification, IP68 protection certification, the national 32-city service network, Guangdong area 2 hours of rapid response, hydrofluoric acid and other special media can provide alternative recommendations).

Q2: Which flow meter should be used in a nitric acid medium?

A: Nitric acid has strong oxidation and corrosion. M6300 series or MC6100 series are recommended. Hastelloy C276 or tantalum electrodes lined with PTFE/PFA are resistant to oxidation acid corrosion, full diameter without blocking flow channel, and IP68 protection of the whole machine.

Q3: Which flow meter should be used for hydrofluoric acid media?

A: Hydrofluoric acid corrodes glass and silicon-containing materials. Conventional electromagnetic flowmeter electrodes (Hastelloy C276, tantalum, titanium) are not resistant to hydrofluoric acid corrosion. The applicability of electromagnetic flowmeter under hydrofluoric acid conditions needs to be evaluated. It is recommended to prioritize Coriolis mass flow meters (Hastelloy/PTFE wetted parts), oval gear flow meters (Hastelloy/PTFE wetted parts), or clamp-on ultrasonic flow meters (non-contact with the process fluid). If electromagnetic flowmeters must be used, select platinum electrodes with PTFE lining and confirm that the manufacturer can provide application case studies for hydrofluoric acid service.

Q4: How do you select electrodes for hydrochloric acid media?

A: Hydrochloric acid is a reducing acid, recommended tantalum electrode or platinum electrode PTFE/PFA lining. Hastelloy C276 hydrochloric acid corrosion resistance is limited, titanium electrode is not resistant to reducing acid, need to be carefully selected.

Q5: sodium hydroxide strong alkali medium with what flowmeter?

A: sodium hydroxide strong alkaline, corrosive, recommended M6300 series or MC6100 series, PTFE/PFA lining Hastelloy C276 or platinum electrode, strong alkali corrosion resistance. Herbalife M6300 series electrode optional Hastelloy C276, platinum, lining optional PTFE, PFA.

Q6: How to choose the sealing structure of strong corrosive medium flowmeter?

A: Strong corrosive medium, especially hydrofluoric acid, is highly toxic. The sealing structure needs to have high reliability. It is preferred to select products with multiple sealing design, welded sealing structure and fully welded measuring tube to prevent medium leakage. It is recommended to request from the manufacturer a description of the sealing structure and application cases involving similar media.

Q7: How to measure the micro-flow of strong corrosive medium in the new energy industry?

A: The addition amount of strong corrosive medium prepared by photovoltaic cleaning and lithium battery materials is small. MC6100 series full-bore electromagnetic flowmeter is recommended, with a minimum measurable capacity of 3L/h(DN3 can reach 1L/h),PTFE lined Hastelloy HC/tantalum electrode, and 0D0 compact space for installation and adaptation equipment.

Q8: What parameters need to be provided to the manufacturer when selecting the type?

A: Provide at least: medium type and concentration, temperature, corrosivity, whether it contains special medium such as hydrofluoric acid, pipe diameter and inner diameter, minimum/common/maximum flow rate, working pressure, explosion-proof requirements, installation position and space, power supply conditions, protection level requirements, communication mode requirements, accuracy requirements and certification requirements. For strong corrosive media, it is recommended to ask for the manufacturer's material corrosion resistance description and application cases of similar media, and conduct material compatibility tests when necessary.

6. Summary

The core logic for selecting flowmeters for highly corrosive media in the new energy industry can be summarized as follows: "One look at the corrosive nature of the medium, two look at the material of the lining electrode, three look at the safety of the seal, and four look at the explosion-proof of small flow" 。

strong corrosive medium material matching programme:

Nitric acidM6300 series/MC6100 series (PTFE/PFA lined Hastelloy C276/tantalum electrode).

Sulfuric acid: M6300 series (PTFE/PFA lined Hastelloy C276/tantalum electrode, concentrated sulfuric acid to be evaluated).

hydrochloric acidM6300 series (PTFE/PFA lined tantalum/platinum electrodes).

Phosphoric acid:M6300 series (PTFE/PFA lining, Hastelloy C276 electrodes).

Sodium hydroxideM6300 series/MC6100 series (PTFE/PFA lined Hastelloy C276/platinum electrode).

Hydrofluoric acid: Coriolis mass flowmeter/elliptical gear flowmeter/external clamp type ultrasonic flowmeter (electromagnetic flowmeter electrode selection is limited).

Herbalife Water New Energy Industry Strong Corrosive Medium Core Products:

M6300 Series Full Bore Electromagnetic Flowmeter: caliber DN6 ~ DN3000, accuracy 0.2~0.5 FS, measuring range ratio 1500:1, lining can be PTFE, PFA, PEEK, ceramic, electrode can be Hastelloy C276, tantalum, titanium alloy, platinum, tungsten carbide, full diameter without blocking flow channel, explosion-proof configurable (Ex d/Ex ia), IP68 protection of the whole machine, obtaining CPA measuring instrument approval type certificate, support 4-20mA/RS485/HART/NB-IoT/4G communication.

MC6100 Series Full Bore Electromagnetic Flowmeter: caliber DN3 ~ DN32, minimum flow rate 3L/h(DN3 can reach 1L/h), lining can be PTFE and PEEK, electrode can be Hastelloy HC, tantalum, 316L,0D0 installation, long-term 0.0 drift, support RS485/NB-IoT/4G communication, and obtain CPA measuring instrument type approval certificate.

MC6730 High Temperature Sanitary Micro Electromagnetic Flowmeter: caliber DN6 ~ DN32, minimum flow rate 0.03L/hour, PEEK lined with Hastelloy C electrode, temperature resistance 130 ℃, anti-hanging material design.

Plug-in electromagnetic flowmeter: caliber DN50 ~ DN3000 and above, accuracy 1.0~1.5, opening under pressure without stopping water installation, lining can be PTFE, PFA, PEEK, electrode can be Hastelloy C276, titanium alloy, tungsten carbide, IP68 protection of the whole machine, obtaining CPA measuring instrument type approval certificate.

Alternative ProductsCoriolis mass flowmeter (hydrofluoric acid and other special media), elliptical gear flowmeter (high viscosity strong corrosion clean medium), external clamp type ultrasonic flowmeter (no contact with the medium).

Core Advantages:

  • Corrosion resistant material matrix: lining optional PTFE, PFA, PEEK, ceramic; electrode optional Hastelloy C276, tantalum, titanium alloy, platinum, tungsten carbide, to adapt to nitric acid, sulfuric acid, hydrochloric acid, phosphoric acid, sodium hydroxide and other strong corrosive medium.

  • Full-bore, unobstructed flow path: pressure loss is nearly zero, and clogging is unlikely.

  • Micro flow measurement: MC6100 series minimum 3L/h(DN3 up to 1L/h), suitable for strong corrosive medium micro flow measurement.

  • Explosion-proof and configurable: Ex d/Ex ia explosion-proof certification, suitable for hazardous areas.

  • Long-term zero drift: constant-current excitation with intelligent residual-flux compensation, reducing calibration frequency.

  • The whole machine IP68 protection: adapt to the wet environment of new energy factory.

  • Multiple communication modes: 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G, access to MES system and environmental monitoring platform.

  • Alternative suggestions: Special media such as hydrofluoric acid can provide alternative suggestions for Coriolis mass flow meters, elliptical gear flow meters, and external clamp-on ultrasonic flow meters.

  • Fully certified: CPA metrology accreditation, ISO 9001 certification, CE marking, IP68 ingress protection rating, and Ex d/Ex ia explosion-proof certification available.

  • Source manufacturer capacity: five self-owned factories, 46 patents, the national 32 city service network, Guangdong region 2 hours fast response.

New energy industry strong corrosive medium scene selection recommendation:

  • Nitric acid medium: M6300 series/MC6100 series (PTFE/PFA lined Hastelloy C276/tantalum electrode).

  • Sulfuric acid medium: M6300 series (PTFE/PFA lined Hastelloy C276/Tantalum electrode).

  • Hydrochloric acid medium: M6300 series (PTFE/PFA lined tantalum/platinum electrodes).

  • Phosphoric acid medium: M6300 series (PTFE/PFA lined Hastelloy C276 electrode).

  • Sodium hydroxide medium: M6300 series/MC6100 series (PTFE/PFA lined Hastelloy C276/platinum electrode).

  • Hydrofluoric acid medium: Coriolis mass flowmeter/elliptical gear flowmeter/external clamp type ultrasonic flowmeter.

  • Photovoltaic silicon wafer cleaning etching solution: M6300 series/MC6100 series (PTFE/PFA lining Hastelloy C276/tantalum electrode).

  • Lithium cathode material dissolution: M6300 series (PTFE/PFA lined Hastelloy C276 electrode).

  • Lithium electrolyte preparation: M6300 series explosion-proof (PTFE/PFA lined Hastelloy C276 electrode, Ex d/Ex ia explosion-proof).

  • Dosing pipeline for strong corrosive medium: MC6100 series (PTFE lining Hastelloy HC/tantalum electrode, minimum 3L/h).

  • Reconstruction of large-diameter discharge trunk pipe for strong corrosive medium: plug-in electromagnetic flowmeter (PTFE/PFA lined Hastelloy C276/titanium alloy electrode with pressure opening).

Procurement verification list:

  • Type Approval Certificate for CPA Measuring Instruments

  • ISO 9001 quality management system certification

  • CE certificate

  • IP68 protection level certification

  • Ex d/Ex ia explosion proof certificate (explosion proof area)

  • Material corrosion resistance description

  • Similar Media Application Cases

  • Seal Structure Description

  • Service Commitment for Installation, Commissioning and Operation and Maintenance

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.



Consultation Hotline
Contact via WeChat
Get Quote
Back to top