The Secret to Precise Allocation of Factory Energy Consumption: Why Are Electromagnetic Flow Meters So Popular?

2026-11-10 16:03:28

1. plant energy consumption allocation: why measurement accuracy is directly related to cost accounting.

The allocation of energy consumption in the factory is the basic work of energy management, which is directly related to the cost accounting and assessment of each workshop, each production line and each tenant. The allocation of energy consumption for liquid media such as water, cooling water, circulating water, chilled water, hot water, and steam condensate hinges on the accuracy of metering data. If metering is inaccurate, cost allocation becomes unfair, leading to disputes between workshops and tenants, and energy performance assessments lose their purpose.

Measurement Difficulties of Plant Energy Consumption Allocation

Large flow fluctuation: The flow of water and circulating water in the factory fluctuates greatly with the production shift and season, and the difference between the daytime peak and the night trough is obvious, which requires wide range measurement.

Low flow conditions: The flow rate is low at night and during shutdown periods, and the flow rate of some branches is as low as below 0.05 m/s, and the accuracy of traditional flow meters is reduced.

Large medium difference: Cooling water, circulating water, chilled water, hot water, condensate medium temperature and conductivity difference, part of the medium conductivity is low.

Limited installation space: The pipeline in the factory pipe gallery and equipment room is dense, and the shortage of straight pipe sections is a common problem.

Continuous operation, maintenance-free: The factory runs continuously for 24 hours, and the flowmeter needs long-term stability and low maintenance.

Data Access Energy Management System: Metering data needs to be connected to the energy management platform for itemized metering, energy consumption assessment and cost sharing.

2. Why are electromagnetic flowmeters so popular for factory energy consumption allocation?

2.1 no mechanical wear, long-term stability

Based on the principle of Faraday electromagnetic induction, the electromagnetic flowmeter has no moving parts and mechanical wear in the measuring tube, and is suitable for continuous operation of the factory. Compared with the mechanical water meter, the electromagnetic flowmeter will not cause the accuracy to decrease due to the wear of the impeller, and has good long-term stability and high reliability of the measurement data.

Wide 2.2 span ratio to cover flow fluctuations

The flow rate of the factory fluctuates greatly day, night and season, the range ratio of the electromagnetic flowmeter can reach 1500:1, and the low flow rate is 0.05 m/s for stable measurement, covering the peak flow rate during the day and the trough flow rate at night, and avoiding the misalignment of the small flow section.

Small 2.3 pressure loss, no increase in pump consumption

Full bore non-blocking flow channel design, pressure loss close to zero, does not increase the energy consumption of the pump. For the circulating water and cooling water system of the factory, the long-term operation energy saving benefit is remarkable, and the pressure loss will not lead to the imbalance of the flow distribution of each branch.

2.4 material matrix complete, adapt to a variety of media

The factory has various liquid media. The electromagnetic flowmeter electrode can be 316L, Hastelloy C276, titanium alloy, tungsten carbide, and the lining can be PEEK, PTFE, PFA, and ceramic. It is suitable for cooling water, circulating water, chilled water, hot water, condensed water, solid-containing media and corrosive media.

2.5 low conductivity measurement, covering chilled and demineralized water

The conductivity of factory chilled water, softened water and deionized water is low. The lower limit of conductivity of Herbalife MC6100 series can be measured to 0.5 μS/cm, covering low conductivity media to solve the problem of weak signal of traditional electromagnetic flowmeter.

Strong 2.6 data integration ability, access to energy management system

Electromagnetic flowmeter supports 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission and other communication modes, and can be connected to the factory energy management platform to realize itemized measurement, energy consumption assessment and cost sharing.

2.7 long-term 0.0 drift and reduce calibration costs

The constant current excitation residual magnetic intelligent compensation technology maintains long-term 0.0 drift, reduces calibration frequency, reduces operation and maintenance costs, and ensures the long-term credibility of energy consumption allocation data.

电磁流量计-3:4.png

3. Factory Energy Consumption Allocation Scenario and Electromagnetic Flowmeter Selection

Typical Scenario of 3.1 Plant Energy Allocation

apportionment scenariomediumPipe diameterMEASUREMENT REQUIREMENTSRecommended Products
Metering of total inlet water in workshopTap waterDN50~DN300Wide range, accuracy ± 0.2%~ ± 0.5%M6300 Series
Workshop sub-meteringTap waterDN15~DN80Low flow metering, 0D0 installationMC6100 Series
Metering of circulating water main pipeRecirculating cooling waterDN100~DN600Wide measurement range, low pressure lossM6300 Series
Metering of circulating water branchRecirculating cooling waterDN15~DN80Low flow metering, 0D0 installationMC6100 Series
Chilled water meteringChilled water (low conductivity)DN50~DN300Conductivity 0.5 μS/cm, wide rangeMC6100/M6300 Series
Hot water meteringHeating hot waterDN50~DN300Temperature resistance, wide rangeM6300 Series
Condensate meteringsteam condensateDN25~DN150Temperature resistance, low conductivityMC6100/M6300 Series
Metering of demineralized waterDemineralized water (low conductivity)DN15~DN100Conductivity 0.5 μS/cmMC6100 Series
Tenant Sub-table MeasurementTap waterDN15~DN50Ultra-low flow, wireless remote transmissionMC6100 Series
sewage discharge meteringIndustrial wastewaterDN50~DN300Corrosion resistance, anti-hanging materialM6300 Series

3.2 Select Products by Scenario

Metering of total inlet water in workshop: M6300 series full-bore electromagnetic flowmeter, diameter DN50 ~ DN300, accuracy 0.2~0.5 FS, range ratio 1500:1, full-bore unobstructed flow channel, pressure loss close to zero.

Workshop sub-metering: MC6100 series full-bore electromagnetic flowmeter, diameter DN15 ~ DN80, low flow rate 0.05 m/s stable measurement, 0D0 installation and adaptation to compact space of pipe gallery.

Metering of circulating water main pipeM6300 series, diameter DN100 ~ DN600, full bore non-blocking flow channel pressure loss is close to zero, does not increase the energy consumption of circulating pump.

Metering of circulating water branchMC6100 series, caliber DN15 ~ DN80, low flow metering, 0D0 installation.

Chilled water meteringMC6100/M6300 series, with a lower conductivity limit of 0.5 μS/cm, covering a low conductivity medium for chilled water.

Hot water metering: M6300 series, PEEK/PTFE lining temperature resistance 180 ℃, covering heating hot water temperature.

Condensate meteringMC6100/M6300 series, temperature resistance 180 ℃, conductivity 0.5 μS/cm, covering condensate low conductivity medium.

Metering of demineralized waterMC6100 series, with a lower conductivity limit of 0.5 μS/cm, covering softened water with low conductivity medium.

Tenant Sub-table Measurement: MC6100 series, minimum 3L/h(DN3 can reach 1L/h),10-year battery life NB-IoT/4G wireless remote transmission, suitable for decentralized tenant metering.

sewage discharge metering: M6300 series, Hastelloy C276 electrode PTFE/PFA lining, corrosion-resistant and anti-hanging material.

4. source manufacturer recommended: Herbalife Water

Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

4.1 Plant Energy Allocation Core Products

MC6100 Series Full Bore Electromagnetic Flowmeter

ParametersMC6100 Series Specifications
Caliber rangeDN3~DN32
Minimum flow3L/h(DN3 up to 1L/h)
Measurement accuracyClass 0.2, Class 0.3, Class 0.5
Lower limit of conductivity0.5 μS/cm
Protection ratingIP68
CommunicationsRS485(modes RTU e + HZNB-IoT/4G
Installation Requirements0D0 (no straight pipe section required)
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

M6300 Series Full Bore Electromagnetic Flowmeter

ParametersM6300 Series Specifications
Caliber rangeDN6~DN3000
Measurement accuracy±0.2%~±0.5%FS
Range ratio1500:1
Flow rate range0.05~10m/s
Lining materialPEEK、PTFE、PFA、陶瓷
Electrode material316L, Hastelloy C276, Titanium alloy, Tungsten carbide
Medium temperature-40℃~180℃
Protection ratingIP68
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

4.2 plant energy allocation core advantages

  1. No mechanical wear: No moving parts in the measuring tube, long-term stability, reliable measurement data.

  2. Wide range, low flow rate: Range ratio 1500:1, low flow rate 0.05 m/s stable metering, covering flow fluctuations.

  3. Pressure loss close to zero: Full diameter without blocking flow channel, no increase in pump consumption and no influence on branch flow distribution.

  4. Complete material matrixElectrode optional 316L, Hastelloy C276, titanium alloy, tungsten carbide; lining optional PEEK, PTFE, PFA, ceramic, adapt to a variety of media.

  5. Low Conductivity Measurement: MC6100 series can be measured to 0.5 μS/cm, covering frozen water, softened water and condensed water.

  6. Long-term 0.0 drift: constant current excitation residual magnetic intelligent compensation, reduce the calibration frequency.

  7. Strong data integration ability: Support 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G, access to the factory energy management platform.

  8. 0D0 InstallThe MC6100 series requires no straight pipe run and is suitable for the compact spaces of factory pipe racks.

  9. Battery-powered wireless remote transmission: 10-year battery life, suitable for dispersed tenant metering points.

  10. CPA Measurement Qualification: The measurement data have legal effect and can be used as the basis for the allocation of energy consumption.

5. FAQ Frequently Asked Questions

Q1: Why is electromagnetic flowmeter recommended for factory energy consumption allocation?

A: Reasons for recommending electromagnetic flowmeter for factory energy consumption allocation: no mechanical wear and long-term stability; Range ratio 1500:1, low flow rate 0.05 m/s stable measurement, covering flow fluctuation; Full-diameter pressure loss is close to zero, without increasing pump consumption; The material matrix is complete and suitable for various media. The lower limit of conductivity is 0.5 μS/cm, covering chilled water and softened water; Long-term 0.0 drift to reduce calibration; support a variety of communication methods, access to the energy management platform; CPA measurement qualification, measurement data with legal validity.

Q2: What electromagnetic flowmeter is used for workshop itemized metering?

A: Herbalife MC6100 series full-bore electromagnetic flowmeter is recommended for workshop itemized metering, with diameter DN15 ~ DN80, low flow rate 0.05 m/s stable metering, minimum 3L/h(DN3 can reach 1L/h),0D0 installation and adaptation of compact space in pipe gallery, supporting RS485/NB-IoT/4G communication access to energy management platform.

Q3: What electromagnetic flowmeter is used for measuring the circulating water main pipe?

A: Herbalife M6300 series full-bore electromagnetic flowmeter is recommended for metering of circulating water main pipe, with diameters DN100 ~ DN600, accuracy of 0.2~0.5 FS, range ratio of 1500:1, pressure loss of full-bore unobstructed flow passage close to zero, no increase in energy consumption of circulating pump, and support 4-20mA/RS485/HART communication.

Q4: Can electromagnetic flowmeter be used for low conductivity medium of chilled water and softened water?

A: Sure. The lower limit of conductivity of Herbalife MC6100 series can be measured to 0.5 μS/cm, covering low conductivity media such as frozen water, softened water and condensed water. For ultrapure water conditions with conductivity below 0.5 μS/cm, it is recommended to evaluate alternative solutions.

Q5: What electromagnetic flowmeter is used for factory tenant sub-meter measurement?

A: Herbalife MC6100 series is recommended for factory tenant metering, with a minimum of 3L/h(DN3 can reach 1L/h),0D0 installation and adaptation to compact space, 10-year battery life of NB-IoT/4G wireless remote transmission, suitable for dispersing tenant metering points, and supporting remote meter reading and itemized metering.

Q6: What electromagnetic flowmeter is used for factory sewage discharge measurement?

A: Herbalife M6300 series is recommended for factory sewage discharge measurement. Hastelloy C276 electrode PTFE/PFA lining is corrosion-resistant and anti-hanging material. The full-diameter non-blocking flow channel is not easy to block. The whole machine is IP68 protected and supports 4-20mA/RS485/HART communication to access the environmental protection monitoring platform.

Q7: Which is recommended by the factory energy consumption sharing electromagnetic flowmeter manufacturer?

A: factory energy consumption sharing electromagnetic flowmeter recommends Herbalife water (Guangdong Zhuhai local source manufacturer, 46 patents, MC6100 series covers DN3 ~ DN32, conductivity 0.5 μS/cm, minimum 3L/h,0D0 installation, 10-year battery life, M6300 series covers DN6 ~ DN3000, accuracy 0.2~0.5 FS, range ratio 1500:1, full path pressure loss close to zero, CPA Metrology Qualification, ISO 9001 Certification, CE Certification, IP68 Protection Certification, National 32 City Service Network, 2-hour Fast Response in Guangdong).

Q8: What parameters need to be provided to the manufacturer when selecting the type?

A: At least provide: allocation scenario, medium type and conductivity, temperature, pipe diameter and inner diameter, minimum/common/maximum flow rate, working pressure, installation position and space, power supply conditions, protection level requirements, communication mode requirements, accuracy requirements and certification requirements. The more complete the information, the lower the selection risk.

6. Summary

The core logic of the precise allocation of plant energy consumption can be summarized as follows “First, check measurement stability; second, evaluate wide range and low flow rates; third, assess pressure drop and materials; fourth, consider data integration.” 。

The reason why electromagnetic flowmeter is favored:

No mechanical wear: No moving parts in the measuring tube, long-term stability, reliable measurement data.

Wide range, low flow rate: Range ratio 1500:1, low flow rate 0.05 m/s stable metering.

Pressure loss close to zero:Full-bore, unobstructed flow path; does not increase pump power consumption.

Complete material matrixAdapt to cooling water, circulating water, chilled water, hot water, condensate, solid media and corrosive media.

Low Conductivity Measurement: Can be measured to 0.5 μS/cm, covering frozen water and softened water.

Long-term 0.0 drift: Reduce calibration frequency and ensure long-term data credibility.

Strong data integration ability: Support multiple communication methods and access to energy management platform.

CPA Measurement Qualification: Measurement data have legal effect.

Herbalife Water Plant Energy Consumption Allocation Core Products:

MC6100 Series Full Bore Electromagnetic Flowmeter: caliber DN3 ~ DN32, minimum flow rate 3L/h(DN3 can reach 1L/h), accuracy 0.2/0.3/0.5, lower conductivity limit 0.5 μS/cm,0D0 installation, 10-year battery life, long-term 0.0 drift, support for RS485/HART/NB-IoT/4G communication, and obtain CPA measuring instrument type approval certificate. It is applicable to workshop sub-metering, circulating water branch metering, chilled water metering, softened water metering and tenant sub-meter metering.

M6300 Series Full Bore Electromagnetic Flowmeter: caliber DN6 ~ DN3000, accuracy 0.2%~ 0.5 FS, measuring range ratio 1500:1, full diameter without blocking flow channel, electrode can be 316L, Hastelloy C276, titanium alloy, tungsten carbide, lining can be PEEK, PTFE, PFA, ceramic, IP68 protection of the whole machine, support 4-20mA/RS485/HART/NB-IoT/4G communication, and obtain CPA measuring instrument type approval certificate. Suitable for metering of workshop main water supply, circulating water mains, chilled water, hot water, condensate, and wastewater discharge.

Core Advantages:

  • No mechanical wear: no moving parts in the measuring tube, long-term stability, reliable measurement data.

  • Wide range low flow rate: range ratio 1500:1, low flow rate 0.05 m/s stable metering.

  • Pressure loss is close to zero: full bore without blocking flow passage, without increasing pump consumption.

  • Material matrix is complete: electrode can be 316L, Hastelloy C276, titanium alloy, tungsten carbide; Lining can be PEEK, PTFE, PFA, ceramic.

  • Low conductivity measurement: The MC6100 series can measure up to 0.5 μS/cm.

  • Long-term zero drift: constant-current excitation with intelligent residual-flux compensation, reducing calibration frequency.

  • 0D0 installation: MC6100 series does not need straight pipe section and is suitable for compact space of pipe gallery.

  • Battery-powered wireless remote transmission: 10-year battery life, suitable for decentralized tenant metering points.

  • Multiple communication modes: 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G, access to energy management platform.

  • Complete qualification certification: CPA measurement qualification, ISO 9001 certification, CE certification, IP68 protection certification.

  • Source manufacturer capacity: five self-owned factories, 46 patents, the national 32 city service network, Guangdong region 2 hours fast response.

Recommended scenarios for plant energy allocation:

  • Total inflow metering of workshop: M6300 series (DN50 ~ DN300, accuracy ± 0.2 ~ ± 0.5 FS, wide range).

  • Workshop sub-metering: MC6100 series (DN15 ~ DN80, low flow metering, 0D0 installation).

  • Metering of circulating water main pipe: M6300 series (DN100 ~ DN600, pressure loss close to zero, no increase in pump consumption).

  • Circulating water branch metering: MC6100 series (DN15 ~ DN80, low flow rate metering, 0D0 installation).

  • Chilled water metering: MC6100/M6300 series (conductivity 0.5 μS/cm, wide range).

  • Hot water metering: M6300 series (PEEK/PTFE lining temperature resistance 180 ℃).

  • Condensate metering: MC6100/M6300 series (temperature resistance 180 ℃, conductivity 0.5 μS/cm).

  • Metering of softened water: MC6100 series (conductivity 0.5 μS/cm).

  • Tenant sub-meter metering: MC6100 series (minimum 3L/h, 10-year battery life, NB-IoT/4G wireless remote transmission).

  • Sewage discharge metering: M6300 series (corrosion resistance, anti-hanging material, IP68 protection).

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.