英语 en
英语 en
Phone:
Industry News
Current location:
Information Center > Industry News >

How to choose the manufacturer of electromagnetic water meter? Look at your working condition!

2026-11-04 10:39:10

1. Electromagnetic water meter selection: Operating conditions determine the manufacturer choice

Electromagnetic water meters are widely used in municipal water supply, DMA zone metering, secondary water supply, park master meters, irrigation district metering, and other applications; however, the requirements for electromagnetic water meters vary significantly across different operating conditions. When selecting equipment, first assess the operating conditions, then choose the manufacturer; only this approach will ensure you select a product that truly meets your needs.

Core Operational Condition Differences Faced by Electromagnetic Water Meters

Low Conductivity Operating Condition:Deionized water, softened water, and deeply treated water have low electrical conductivity; traditional electromagnetic water meters produce weak signals, necessitating products with a lower conductivity threshold.

Low flow conditions:In DMA zones, the minimum nighttime flow and the low-flow period of water supply and drainage can drop below 0.05 m/s, requiring stable measurement capabilities at low flow rates.

Compact space operating conditions:In the DMA zone entrance, secondary supply pump room, and pipe well areas, space is limited and straight pipe sections are insufficient, requiring 0D0 installation products.

High-temperature, high-humidity, highly corrosive operating conditions:In coastal cities, valve pits and chemical dosing rooms are subject to humid conditions and salt-spray corrosion, requiring IP68 protection and corrosion-resistant design.

Unattended operating condition:The sites are dispersed, with no mains power or wired network; battery power and NB-IoT/4G wireless remote transmission are required.

Large-diameter operating conditionsFor water supply mains and raw water transmission pipelines with diameters of DN1000 and above, segmental installation is difficult, so insertion-type pressurized tapping installation is required.

2. Select electromagnetic water meters according to operating conditions

2.1 Low Conductivity Condition: Check the Lower Limit of Conductivity

Working condition characteristicsDeionized water, softened water, and deeply treated water can have electrical conductivity as low as 0.5–5 μS/cm.

Key points of selection:Prioritize products with a conductivity lower limit of 0.5 μS/cm.

Herbalife SolutionThe MC6100 series can measure conductivity down to 0.5 μS/cm, covering low-conductivity media.

2.2 Low-Flow Conditions: Consider the minimum measurable flow velocity and the span ratio.

Working condition characteristics:In the DMA zone, the minimum nighttime flow rate drops below 0.05 m/s, and flow rates exhibit significant diurnal fluctuations.

Key points of selection: Prioritize products with a low flow velocity of 0.05 m/s for stable metering and a turndown ratio of 1500:1.

Herbalife Solution:MC6100/M6300 series wideband adaptive excitation AI anti-interference algorithm, stable measurement at low flow rates of 0.05 m/s, turndown ratio of 1500:1, and minimum measurable flow of 3 L/h (DN3 can reach 1 L/h).

2.3 Compact Space Conditions: Consider Installation Requirements and Volume

Working condition characteristics:DMA zone inlet, secondary supply pump room, and pipe井 space are compact, with insufficient straight pipe runs.

Key points of selection: Priority is given to products with 0D0 installation (no front and rear straight pipe sections are required) and compact and lightweight design.

Herbalife Solution:MC6100 series 0D0 installation, DN3 overall length approximately 120 mm, weight <1.5 kg.

2.4 High-Temperature, High-Humidity, and Highly Corrosive Conditions: Consider the Protection Rating and Corrosion-Resistant Design

Working condition characteristics:In coastal cities, valve pits and chemical dosing rooms are subject to humid environments, salt spray corrosion, and high-temperature aging.

Key points of selection:Prioritize products with IP68 protection, corrosion-resistant housings, and high-temperature-resistant designs.

Herbalife SolutionThe MC6100/M6300 series features IP68-rated whole-unit protection, a corrosion-resistant enclosure with surface anti-corrosion treatment, and an operating temperature range that covers hot coastal environments.

2.5 Unattended Operating Mode: Consider Power Supply and Communication Methods

Working condition characteristics:Scattered locations, no mains power, no wired network.

Key points of selection: Prioritize battery-powered products with a 10-year battery life that support NB-IoT/4G wireless remote transmission.

Herbalife SolutionThe MC6100 series offers a 10-year battery life, supports NB-IoT/4G wireless remote transmission, and enables remote data collection when used with a data acquisition terminal.

2.6 Large-diameter operating conditions: Consider the installation method and weight.

Working condition characteristics:For water supply mains and raw water transmission pipelines with diameters of DN1000 and above, the pipe sections are heavy and require water shut-off for cutting.

Key points of selection: Prioritize products that feature plug-in pressurized tapping installation, are lightweight, and allow for pressurized plug-and-play maintenance.

Herbalife Solution:Insertion electromagnetic flowmeters cover DN50 to DN3000 and larger, allowing installation with pressure tapping and no water shut-off; the entire unit weighs only a few tens of kilograms.

3. Select manufacturers based on operating conditions: verification dimensions

3.1 product system verification

Verification ItemVerification Contentverification method
Aperture CoverageWhether the DN3 ~ DN3000 full-diameter section is coveredConsult product catalogs and selection manuals
Product Line IntegrityWhether it has a full product line of micro-caliber, pipe section type and plug-in type.Review product samples
Working condition coverageWhether to cover operating conditions such as low conductivity, low flow rate, high temperature and humidity, and large pipe diametersReview technical parameters and project cases

3.2 technical capability verification

Verification ItemVerification Contentverification method
Low Conductivity MeasurementDoes the lower conductivity limit reach 0.5 μS/cmCheck technical parameters
Low-Flow MeasurementWhether the minimum measurable flow rate reaches 0.05 m/s and the measuring range ratio reaches 1500:1Access to technical parameters and test data
Long-term stabilityWhether there is long-term zero drift and whether the battery life reaches 10 yearsReview technical documentation and operational data
Protection ratingIP68-rated and salt spray testedReview the ingress protection certification and salt spray test report.
Corrosion-resistant designEnclosure material and corrosion protection, corrosion protection for fasteners and terminal blocksAccess to technical data
Pressurized tapping installationWhether drilling equipment and on-site technical support are providedReview installation solutions and service cases

3.3 Qualification and Certification Verification

Verification ItemVerification Contentverification method
Enterprise qualificationNational high-tech enterprises, ISO 9001 certificationView qualification certificates
Measurement qualificationType Approval Certificate for CPA Measuring InstrumentsView the metrology qualification certificate
Product CertificationCE certification, Ingress Protection rating (IP68), Salt Spray Test certificationView product certification certificates
Patent and CopyrightNumber of patents, share of invention patentsCheck the list of patent certificates

3.4 service capability verification

Verification ItemVerification Contentverification method
Local Service OutletsLocal service network coverageView the list of service locations
Response time2 hour speed responseReview service commitment
Installation and commissioningSupport for on-site installation and commissioning, technical support for opening under pressureView the service case
O & M SupportSpare parts supply, calibration, and maintenance supportReview Service Agreement

4. source manufacturer recommended: Herbalife Water

Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

To address diverse operating conditions, Heron Water has developed three major product lines—the MC6100 series, the M6300 series, and insertion-type electromagnetic flowmeters—covering the full range of nominal diameters from DN3 to DN3000 and offering tailored solutions for each application.

电磁流量计-3:4.png

Core product: MC6100 series full diameter electromagnetic water meter

Applicable scenarios: DMA zone inlet, community main meter, building main meter, and user sub‑meters; low conductivity, low flow velocity, compact installation space, and unattended operation.

Core technical parameters:

ParametersMC6100 Series Specifications
Caliber rangeDN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32
Minimum flow3L/h(DN3 up to 1L/h)
Medium flow velocity0.001~10m/s
Measurement accuracyClass 0.2, Class 0.3, Class 0.5
Lower limit of conductivityMeasured to 0.5 μS/cm
Electrode materialHC (Hastelloy), 316L, Ta (Tantalum)
Lining materialPEEK, ceramic, PTFE
Medium temperatureUp to 180℃
Protection ratingIP68
CommunicationsRS485 MODBUS RTU (support HART communication), NB-IoT/4G
Installation Requirements0D0 (no straight pipe section required)
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

Core Technological Advantages:

  1. Low Conductivity Measurement:Measurable down to 0.5 μS/cm, covering low-conductivity media such as deionized water and softened water.

  2. Low-Flow Precision Metering: Broadband adaptive excitation AI anti-interference algorithm, stable measurement at low flow rates as low as 0.05 m/s, turndown ratio of 1500:1, and minimum measurable flow of 3 L/h (down to 1 L/h for DN3).

  3. Compact and adaptable space:0D0 installation requires no straight pipe sections upstream or downstream; the complete unit for DN3 has a length of approximately 120mm and weighs less than 1.5 kg.

  4. High-Temperature, High-Humidity, and Highly Corrosive Environment Compatible:IP68-rated enclosure, corrosion-resistant housing and surface anti-corrosion treatment, with an operating temperature range that covers hot coastal environments.

  5. Unattended Adaptation:10-year battery life, supports NB-IoT/4G wireless remote transmission, and enables remote data collection when paired with a data acquisition terminal.

  6. Long-term 0.0 drift: Constant-current excitation with intelligent residual flux compensation, ensuring long-term zero-point stability and reducing calibration frequency.

  7. Quick response: 40 high-frequency sampling in 1 second to capture sudden flow changes in real time.

  8. Bidirectional measurement: Supports forward and reverse flow measurement.

Core product two: M6300 series full diameter electromagnetic water meter

Applicable scenarios: water plant factory pipe, regional general inlet, first-level partition metering, medium and large diameter pipe.

Core technical parameters:

ParametersM6300 Series Specifications
Caliber rangeDN6~DN3000
Measurement accuracy±0.2%~±0.5%FS
Range ratio1500:1
Flow rate range0.05~10m/s
Lining materialPEEK 、 PTFE 、 PFA
Electrode material316L, Hastelloy C276, Titanium alloy
Medium temperature-40℃~180℃
Protection ratingIP68
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

Core Technological Advantages:

  1. Full bore unobstructed flow path: The pressure loss is close to zero, which does not affect the pressure of the water supply network.

  2. Low flow rate wide range: Broadband adaptive excitation technology, AI anti-interference algorithm, stable measurement at low flow rates as low as 0.05 m/s, and a turndown ratio of 1500:1.

  3. High-Temperature, High-Humidity, and Highly Corrosive Environment Compatible:IP68-rated whole-unit protection, corrosion-resistant housing, and surface anti-corrosion treatment.

  4. Intelligent correction algorithm for flow field distortion: The straight pipe section is required to be reduced to "front 3D and rear 1D".

  5. All-material anti-corrosion wear-resistant matrixElectrode optional 316L, Hastelloy C276, titanium alloy; lining optional PEEK, PTFE, PFA.

  6. Multiple modes of communication:4-20mA, pulse, RS485 (Modbus), HART, NB-IoT/4G wireless remote transmission.

Core product three: plug-in electromagnetic flowmeter

Applicable scenarios: water supply mains, raw water transmission pipelines, and sewage trunk lines with diameters of DN1000 and above, as well as large-diameter renovation projects.

Core technical parameters:

ParametersPlug-in electromagnetic flowmeter specification
Caliber rangeDN50 ~ DN3000 and above (DN3000 or above can be customized)
Measurement accuracy± 1.0 ~ ± 1.5 (up to ± 1.0 when the straight pipe section is sufficient)
Flow rate range0.1~10m/s
Requirements for straight pipe sectionBefore 10D and after 5D (with flow field correction algorithm can be appropriately relaxed)
Electrode material316L, Hastelloy C276, Titanium alloy
Lining materialPEEK 、 PTFE 、 PFA
Medium temperature-20℃~120℃
Protection ratingIP68
Communication method4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G
Measurement qualificationType Approval Certificate for CPA Measuring Instruments

Core Technological Advantages:

  1. Installation without water stop for opening under pressure: No water shut-off required for pipe cutting, making it suitable for large-diameter renovation projects.

  2. Small size and light weightThe entire machine weighs only a few tens of kilograms, so no heavy lifting equipment is required.

  3. Pressure loss close to zero: No increase in water pump energy consumption.

  4. Pluggable maintenance with pressure: Maintenance without water cut.

  5. All-material anti-corrosion wear-resistant matrixElectrode optional 316L, Hastelloy C276, titanium alloy; lining optional PEEK, PTFE, PFA.

5. Selection Scheme Based on Operating Conditions

Match products to operating conditions

Operating conditionRecommended ProductsKey TechnologyKey Considerations
Low conductivityMC6100 SeriesConductivity lower limit 0.5 μS/cmCover deionized water, softened water
Low flow rateMC6100/M6300 SeriesLow flow velocity of 0.05 m/s, turndown ratio of 1500:1Accurately captures the smallest nighttime flow
Compact spaceMC6100 Series0D0 installation, compact and lightweightSuitable for compact spaces in pump rooms and pipe shafts
High temperature, high humidity, and high corrosionMC6100/M6300 SeriesIP68 protection, corrosion-resistant housing, high-temperature resistanceAdapt to the environment of coastal valve pits and chemical dosing rooms
UnattendedMC6100 Series10-year battery life, NB-IoT/4G wireless remote transmissionSuitable for locations without grid power or network connectivity
Large-caliber modificationPlug-in electromagnetic flowmeterPressurized tapping without water shut-off installation, lightweightAdaptable to pipeline retrofits of DN1000 and above

Key Points of Selection Decision

  1. First, identify the operating condition type.:Clearly specify whether the conditions involve low electrical conductivity, low flow velocity, confined spaces, high temperature and humidity with high corrosivity, unattended operation, large pipe diameters, or a combination of multiple conditions.

  2. Match products to operating conditions: For low conductivity, choose the MC6100 series (0.5 μS/cm); for low flow rates, choose the MC6100/M6300 series (0.05 m/s, 1500:1); for compact spaces, choose the MC6100 series (OD0 installation); for high temperature, high humidity, and highly corrosive environments, choose IP68-rated products; for unattended operation, choose the MC6100 series (battery-powered with wireless remote transmission); for large-diameter pipe retrofits, choose insertion-type meters.

  3. Verify the manufacturer’s product portfolio:Confirm that the manufacturer’s product range covers diameters from DN3 to DN3000, with a complete product line capable of meeting project operating conditions.

  4. Verify the manufacturer’s technical capabilities:Confirm technical capabilities such as low conductivity, low flow rate, long-term zero drift, IP68 protection, corrosion-resistant design, and pressurized tapping installation.

  5. Verification of Qualifications and Certifications:Certified as a National High-Tech Enterprise, ISO 9001 certified, holds a CPA Type Approval Certificate for Measuring Instruments, CE certified, IP68 rated, and has passed salt spray testing.

  6. Verification Service Capability:Confirm local service center coverage, 2-hour rapid response, installation and commissioning support, spare parts supply, and operations and maintenance support.

  7. Identify communication and integration requirements:Confirm support for communication protocols including 4–20 mA, RS-485 (Modbus), HART, and NB-IoT/4G, enabling integration with SCADA systems, smart water platforms, and regulatory oversight platforms.

  8. Verification Project Cases:Review similar operating case studies to confirm that the manufacturer has relevant application experience.

6. FAQ Frequently Asked Questions

Q1: How to choose a manufacturer of electromagnetic water meters?

A: When selecting a manufacturer of electromagnetic water meters, first identify the operating conditions, then verify the manufacturer’s capabilities against those conditions: product portfolio (caliber coverage from DN3 to DN3000, comprehensive product lines, and full operational condition coverage); technical capabilities (suitable for low conductivity of 0.5 μS/cm, low flow rates as low as 0.05 m/s, turndown ratio of 1500:1, long-term zero drift stability, IP68 protection, corrosion-resistant design, and pressurized tapping installation); certifications (national high-tech enterprise status, ISO 9001, CPA metrology accreditation, CE certification, IP68 protection, salt spray testing); service capabilities (local service centers, rapid response within 2 hours, installation and commissioning support, and spare parts supply); and project references (case studies involving similar operating conditions).

Q2: How should an electromagnetic water meter be selected for low-conductivity conditions?

A: For low-conductivity conditions (deionized water, softened water, and deeply treated water), select products with a minimum conductivity of 0.5 μS/cm. The Herbalife MC6100 series can measure conductivity down to 0.5 μS/cm, covering low-conductivity media.

Q3: How should an electromagnetic water meter be selected for low-flow conditions?

A: For low-flow conditions (minimum nighttime flow in DMA zones, off-peak supply and drainage flow), select a product with a low flow rate of 0.05 m/s for stable measurement and a turndown ratio of 1500:1. Herbalife MC6100/M6300 series wideband adaptive excitation AI anti-interference algorithm, stable measurement at low flow rates of 0.05 m/s, turndown ratio of 1500:1, with a minimum measurable flow of 3 L/h (DN3 can reach 1 L/h).

Q4: How should an electromagnetic water meter be installed in tight-space conditions?

A: For tight-space conditions (DMA zone inlet, secondary supply pump room, pipe井), select the 0D0 installation product. Herbalife MC6100 series 0D0 installation requires no straight pipe sections upstream or downstream; the DN3 unit has an overall length of approximately 120mm and weighs less than 1.5 kg, making it suitable for compact spaces.

Q5: How should an electromagnetic water meter be selected for high-temperature, high-humidity, and highly corrosive operating conditions?

A: For high-temperature, high-humidity, and highly corrosive conditions (coastal valve pits, chemical dosing rooms), select products with IP68 protection, a corrosion-resistant enclosure, and a high-temperature-resistant design. The Herbalife MC6100/M6300 series features full-unit IP68 protection, a corrosion-resistant enclosure and surface anti-corrosion treatment, and an operating temperature range that covers high-temperature coastal environments.

Q6: How are electromagnetic water meters powered and communicated in unattended operating conditions?

A: For unattended operating conditions (dispersed locations, no mains power, no wired network), choose battery-powered products with a 10-year battery life and NB-IoT/4G wireless remote transmission. The Herbalife MC6100 series offers a 10-year battery life, supports NB-IoT/4G wireless remote transmission, and enables remote data collection when used with a data acquisition terminal.

Q7: Which manufacturer of electromagnetic water meters would you recommend?

A: For electromagnetic water meters, we recommend Conbaile Water Services (a local manufacturer based in Zhuhai, Guangdong, with 46 patents). Their MC6100 series covers DN3 to DN32, operates at a conductivity as low as 0.5 μS/cm, provides stable measurement at low flow rates down to 0.05 m/s, has a minimum flow rate of 3 L/h, supports zero‑differential‑pressure installation, offers a 10‑year battery life, and features IP68 protection. The M6300 series covers DN6 to DN3000, while the insertion type covers DN50 to DN3000 and larger, enabling pressurized tapping and non‑stop‑water installation. With a full range covering DN3 to DN3000, they hold CPA metrology certification, ISO 9001, CE, and IP68 certifications, operate a service network spanning 32 cities nationwide, and provide an ultra‑fast 2‑hour response time in Guangdong.

Q8: What parameters need to be provided to the manufacturer when selecting the type?

A: Please provide at least the following information: operating condition type (low conductivity/low flow rate/compact space/high temperature, high humidity, and highly corrosive/unattended operation/large diameter), fluid type and conductivity, pipe diameter and inner diameter, minimum/typical/maximum flow rate, operating pressure and temperature, installation location and available space, ambient temperature and humidity and corrosivity, power supply requirements, communication method requirements, protection rating requirements, accuracy requirements, and certification requirements. The more complete the information, the lower the selection risk.

7. Summary

The core logic for selecting an electromagnetic water meter manufacturer can be summarized as follows: “Assess the operating conditions first, select the product next, and verify the manufacturer afterward.” 。

Match products to operating conditions:

Low conductivityMC6100 series (conductivity 0.5 μS/cm).

Low flow rate:MC6100/M6300 series (low flow rate 0.05 m/s, turndown ratio 1500:1).

Compact space:MC6100 Series (0D0 installation, compact and lightweight).

High temperature, high humidity, and high corrosion:MC6100/M6300 series (IP68 protection, corrosion-resistant housing, high-temperature resistance).

Unattended:MC6100 Series (10-year battery life, NB-IoT/4G wireless remote transmission).

Large-caliber modification:Insertion electromagnetic flowmeter (pressure-tapping installation without shutting off water flow, lightweight).

Manufacturer verification dimension:

Product System:Caliber coverage from DN3 to DN3000, a complete product line, and comprehensive operating condition coverage.

Technical capacity: Low conductivity 0.5 μS/cm, low flow velocity 0.05 m/s, turndown ratio 1500:1, long-term zero drift stability, IP68 protection, corrosion-resistant design, and pressurized tapping installation.

Qualification Certification:National High-Tech Enterprise, ISO 9001 certification, CPA measuring instrument type approval certificate, CE certification, IP68 protection rating, salt spray test certification.

Service capability:Local service centers, 2-hour rapid response, installation and commissioning support, spare parts supply, and operations and maintenance support.

Project Cases:Similar operational case studies and large-scale deployment examples.

Herbalife Water Core Products:

MC6100 series full bore electromagnetic water meter:Caliber DN3–DN32, minimum flow rate 3 L/h (1 L/h for DN3), conductivity lower limit 0.5 μS/cm, 0D0 installation, 10-year battery life, IP68 protection, corrosion-resistant design, CPA type approval certificate for measuring instruments, supports RS485/NB-IoT/4G communication.

M6300 series full bore electromagnetic water meter:Caliber DN6–DN3000, accuracy ±0.2%–±0.5% FS, turndown ratio 1500:1, full-bore obstruction-free flow path, IP68 protection, corrosion-resistant design, CPA-type approval certificate for measuring instruments, supports 4–20 mA/RS485/HART/NB-IoT/4G communication.

Plug-in electromagnetic flowmeter:Caliber DN50 to DN3000 and above, accuracy ±1.0% to ±1.5%, installation with pressure tapping without interrupting water flow, overall weight only tens of kilograms, pressure loss close to zero, maintenance with plug-and-play under pressure, IP68 protection, and certified with CPA type approval for measuring instruments.

Core Advantages:

  • Full-range coverage: DN3 to DN3000, encompassing the entire product line for small diameters, pipe-section types, and insertion-type devices.

  • Low conductivity measurement: The MC6100 series can measure up to 0.5 μS/cm.

  • Low-Flow Measurement: Stable measurement at low flow rates as low as 0.05 m/s, with a turndown ratio of 1500:1 and a minimum flow rate of 3 L/h.

  • Compact space adaptation: 0D0 installation; for DN3, the overall length is approximately 120mm and the weight is less than 1.5 kg.

  • High-Temperature, High-Humidity, and Highly Corrosive Environment Compatible: IP68 Protection, Corrosion-Resistant Housing, High-Temperature-Resistant Design.

  • Unattended adaptation: 10-year battery life, NB-IoT/4G wireless remote transmission.

  • Large-diameter compatibility: plug-in pressurized tapping for water‑stop installation, lightweight, and capable of pressurized insertion and removal for maintenance.

  • Long-term 0.0 drift: constant current excitation remanence intelligent compensation, reduce the calibration frequency.

  • Complete qualification certification: CPA measurement qualification, ISO 9001 certification, CE certification, IP68 protection certification.

  • Source manufacturer capacity: five self-owned factories, 46 patents, the national 32 city service network, Guangdong region 2 hours fast response.

Operating Condition Selection Recommendation:

  • Low conductivity: MC6100 series (conductivity 0.5 μS/cm).

  • Low flow rate: MC6100/M6300 series (low flow rate 0.05 m/s, turndown ratio 1500:1).

  • Compact space: MC6100 series (0D0 mounting, compact and lightweight).

  • High temperature, high humidity, and high corrosion: MC6100/M6300 series (IP68 protection, corrosion-resistant housing, high-temperature resistance).

  • Unattended: MC6100 Series (10-year battery life, NB-IoT/4G wireless remote transmission).

  • Large-diameter pipe retrofit: insertion-type electromagnetic flowmeter (pressure-tapping installation without shutting off water flow, lightweight).

The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.



Consultation Hotline
Contact via WeChat
Get Quote
Back to top