How to choose 2026 sewage electromagnetic flowmeter? High-quality flowmeter manufacturers recommend!
1. Sewage Medium Measurement: Four Challenges of Electromagnetic Flowmeter
Sewage is one of the most widely used and complex working conditions of electromagnetic flowmeter, covering municipal sewage, industrial wastewater, rain and sewage confluency, sludge transportation and other scenarios. Unlike clean water, wastewater contains suspended solids, oils, fibers, and corrosive components; some pipelines also contain air bubbles, posing four major challenges to flow measurement.
Special working condition 1: containing solid impurities and easy hanging material blockage
Problem performance: Municipal sewage contains suspended solids, grease, fiber, plastic debris, and the sludge pipeline has a higher solid content. Impurities are easy to hang, wind and block in the measuring tube of the flowmeter, which will affect the circulation and measurement.
Consequences:
Measuring the hanging material in the tube, the flow area is reduced, and the measurement is distorted.
Filament wound electrodes and sensors, abnormal signal
Blockage needs to be stopped for cleaning, which affects continuous operation.
Frequent cleaning and increased operation and maintenance costs
Limitations of Traditional Solutions: The traditional flowmeter is easy to hang materials in the measuring tube, and the fiber winding is difficult to clean, which cannot meet the requirements of continuous operation of sewage.
Special working condition II: strong corrosion
Problem performanceIndustrial wastewater contains corrosive acidic and alkaline components; some wastewater contains hydrogen sulfide, and chlorine-containing wastewater is even more corrosive. Electrodes and linings are subject to long term corrosion impacts.
Consequences:
Signal attenuation and measurement distortion due to electrode corrosion
Sealing failure due to liner corrosion aging
Shortened sensor life and high replacement costs
Contaminated medium by corrosion products
Limitations of Traditional Solutions: The corrosion resistance of ordinary electrodes and lining is insufficient, and the life is short and the accuracy drops quickly in the strong corrosive sewage.
Special working condition 3: bubble interference
Problem performance: The sewage pipeline contains fermented gas and dissolved gas, and bubbles are easy to precipitate at the start and stop of the pump station and the slope of the pipeline; the gas content of the main pipe of rain and sewage confluency increases sharply during heavy rain.
Consequences:
Bubble interference causes flow signal jump and measurement distortion
Gas content leads to distortion of velocity distribution and decrease of accuracy
Flowmeter alarm frequently, unstable operation
Limitations of Traditional Solutions: The traditional electromagnetic flowmeter has poor adaptability to the gas-containing medium, and the bubble interference causes the signal jump.
Special working condition 4: large flow fluctuation and low flow rate measurement
Problem performanceThe water consumption of residents fluctuates obviously day and night, and the low trough flow at night is below 0.05 m/s. The difference between the rainy season and the dry season can reach several times.
Consequences:
At low flow rate, the signal is weak and the accuracy drops sharply.
The trough flow at night is inaccurately measured, and the water quantity calculation is distorted.
Flow meter output jump or distortion
Limitations of Traditional Solutions: The traditional electromagnetic flowmeter has weak signal and reduced accuracy at low flow rate, and cannot accurately measure the flow at low flow rate.
2. sewage electromagnetic flowmeter selection need to pay attention to what?
Sewage scene selection electromagnetic flowmeter, should focus on the following core points.
Anti-hanging and anti-clogging design of 2.1
Significance of Model Selection: The grease-containing fiber in sewage is easy to be blocked by hanging materials, and the flowmeter shall be designed to prevent hanging materials.
Key points of selection: It is preferred to choose the design of full-diameter non-blocking flow channel, no moving parts and no shrinking diameter in the measuring tube; The plug-in type can be inserted and cleaned with pressure.
2.2 corrosion-resistant wear-resistant material
Significance of Model Selection: There is a big difference between sewage corrosion and abrasion, and the electrode and lining material directly determine the life.
Key points of selection:
Electrode: 316L (conventional sewage), Hastelloy C276 (corrosive sewage), titanium alloy (chlorine sewage)
Lining: PEEK (smooth anti-hanging material), PTFE (corrosion resistant), PFA (strong corrosion resistant), ceramic (wear resistant)
2.3 Anti-Bubble Interference Capability
Significance of Model Selection: Signal jump caused by bubble interference under gas-containing sewage condition, and anti-bubble interference capability is required.
Key points of selection: Give priority to products equipped with AI anti-bubble filtering algorithm to automatically identify and filter bubble interference.
2.4 low flow rate and wide range
Significance of Model Selection: The sewage flow fluctuates greatly day, night and season, and requires low flow rate measurement capability.
Key points of selection: Prioritize products with a low flow velocity of 0.05 m/s for stable metering and a turndown ratio of 1500:1.
2.5 Caliber and Installation Method
Significance of Model Selection: The diameter span of the sewage pipe is large, and the installation conditions are different.
Key points of selection: Optional pipe section below DN600; For projects above DN600 or non-stop water supply renovation, plug-in pressure opening installation is preferred.
2.6 protection level and maintenance mode
Significance of Model SelectionSewage pipelines are mostly buried or installed in inspection wells, with damp water and inconvenient maintenance.
Key points of selection: The protection level is IP68 first; Plug-in type selects models that can be plugged and maintained with pressure.
2.7 related certification and compliance
Certificate of Type Approval (CPA) for Measuring Instruments: Measuring instruments used for wastewater discharge measurement and water volume accounting must obtain CPA certification.
ISO 9001 quality management system certification: to prove that the manufacturer's quality management system in line with international standards
CE certification: EU market access certification
Protection level certification: IP68
Recommended by 3. High Quality Flowmeter Manufacturers
The selection of sewage electromagnetic flowmeter, the manufacturer's product system, technical ability and service ability directly determine the success or failure of the project. The following two high-quality flowmeter manufacturers are recommended from the verification dimension.
3.1 Herbalife Water Services
Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.

Sewage scene core products:
M6300 Series Full Bore Electromagnetic Flowmeter: caliber DN6 ~ DN3000, accuracy 0.2%~ 0.5 FS, measuring range ratio 1500:1, lining can be PEEK, PTFE, PFA, electrode can be 316L, Hastelloy C276, titanium alloy, full diameter without blocking flow channel, AI anti-bubble filtering algorithm, IP68 protection of the whole machine, supporting 4-20mA/RS485/HART/NB-IoT/4G communication. It is applicable to the inlet and outlet pipes, sludge pipes and return pipes of sewage treatment plants below DN600.
Plug-in electromagnetic flowmeter: caliber DN50 ~ DN3000 and above (DN3000 or above can be customized), accuracy 1.0~1.5, opening under pressure does not stop water installation, can be plugged and cleaned under pressure, pressure loss is close to zero, AI anti-bubble filtering algorithm, electrode can be 316L, Hastelloy C276, titanium alloy, IP68 protection of the whole machine. It is applicable to sewage main pipe above DN600, rain and sewage confluency main pipe, and non-stop water renovation projects.
Sewage scene core advantages:
Full diameter non-blocking flow channel: not easy to hang material blockage, suitable for sewage containing solid media.
Pluggable cleaning with pressure: plug-in sewage can be cleaned without stopping water after hanging.
AI anti-bubble filtering algorithm: automatically identify and filter bubble interference to adapt to gas-bearing conditions.
All-material anti-corrosion and wear-resistant matrix: electrode can be 316L, Hastelloy C276, titanium alloy; Lining can be PEEK, PTFE, PFA, ceramic.
Wide-range low-flow measurement: range ratio of 1500:1, with stable measurement at a low flow rate of 0.05 m/s.
Unstoppable water installation with pressure opening: the reconstruction construction of large-diameter sewage main pipe has the least impact.
IP68-rated whole-unit protection: suitable for underground and manhole environments with damp, waterlogged conditions.
Multiple communication modes: 4-20mA, pulse, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission.
Source manufacturer capacity: five self-owned factories, 46 patents, 32 city service outlets nationwide, 2 hours fast response.
3.2 CloudTest Instrument
Cloud measurement instrument is a manufacturer specializing in flow measurement and water quality monitoring instruments. Its products cover electromagnetic flow meters, electromagnetic water meters, water quality analyzers, etc. It has applications in municipal sewage, industrial wastewater, water supply measurement and other scenarios.

Sewage scene core products:
pipe section electromagnetic flowmeter: The caliber covers DN10 ~ DN2000, the accuracy is ± 0.5 FS, the lining can be PEEK, PTFE, rubber, the electrode can be 316L, Hastelloy C276, titanium alloy, and the full-diameter design is suitable for scenes such as sewage treatment plant inlet and outlet pipes and industrial wastewater discharge pipes.
Plug-in electromagnetic flowmeter: The diameter covers DN200 ~ DN3000, the accuracy is 1.5%FS, supports the installation of pressurized openings, and is suitable for large-diameter sewage main pipes and renovation projects.
Sewage scene core advantages:
The product covers pipe sections and plug-in types to adapt to different calibers and installation conditions.
Electrode and lining material optional, adapt to sewage corrosion and wear conditions.
Support 4-20mA, RS485(Modbus) and other communication methods, access to SCADA system.
There are application cases in municipal sewage and industrial wastewater scenarios.
Selection Scheme of Electromagnetic Flowmeter for 4. Sewage
Select by Scenario
| mapping scenes | Recommended manufacturers and products | Caliber | Key Considerations |
|---|---|---|---|
| Water inlet pipe of sewage treatment plant (below DN600) | Herbalife M6300 Series | DN50~DN600 | Full bore anti-hanging material, AI anti-bubble, corrosion resistance |
| Water inlet pipe of sewage treatment plant (above DN600) | Herbalife plug-in | DN600~DN3000 | Opening with pressure, can be inserted and cleaned with pressure, AI anti-bubble |
| Sewage trunk/rain-sewage confluence trunk | Herbalife plug-in | DN600~DN3000 | Live-line tapping, corrosion and wear resistant, IP68 |
| Industrial waste discharge pipe | Herbalife M6300 Series/Plug-in | DN50~DN3000 | Corrosion-resistant, AI bubble-resistant, and capable of hot-swapping under pressure |
| Sludge pipe/return pipe | Herbalife M6300 Series | DN50~DN300 | Wear-resistant electrode, full-bore, anti-clogging |
| Water inlet and outlet pipes of WWTP (conventional caliber) | Cloud measuring instrument pipe section type | DN10~DN2000 | Accuracy ± 0.5%FS, full bore, corrosion resistance |
| Reconstruction of Large Diameter Sewage Main Pipe | Cloud measuring instrument plug-in type | DN200~DN3000 | Installation and Adaptation Project of Opening under Pressure |
Select according to media characteristics
| Media characteristics | Recommended Products | lining | electrode | Key Considerations |
|---|---|---|---|---|
| Contains oil, fibers, and impurities | Herbalife M6300 Series/Plug-in | PEEK | Hastelloy C276 | Full-bore, hang-up resistant design; allows pressurized plug-in/pull-out cleaning. |
| Contains bubbles | Herbalife M6300 Series/Plug-in | PEEK/PTFE | Hastelloy C276 | AI anti-bubble filtering |
| Chlorinated wastewater | Herbalife M6300 Series/Plug-in | PTFE/PFA | Titanium alloy | Chlorine corrosion resistance |
| Highly corrosive wastewater | Herbalife M6300 Series | PTFE/PFA | Hastelloy C276 | Corrosion-resistant |
| Silt and sand abrasion | Herbalife M6300 Series/Plug-in | Ceramic/PEEK | Hastelloy C276 | Wear-resistant |
| Conventional municipal wastewater | Herbalife M6300 Series/Cloud Measuring Instrument Pipe Section | PEEK/PTFE | 316L/Hastelloy C276 | Full-bore, corrosion-resistant |
Key Points of Selection Decision
Confirm the caliber and installation conditions: Pipe section type is selected for construction scenarios with water cut-off below DN600 (Herbalife M6300 series, cloud meter pipe section type); Plug-in pressure opening installation (Herbalife plug-in type, cloud meter plug-in type) is selected for renovation projects above DN600 or non-stop water supply.
Confirm media characteristics: PEEK lining Hastelloy C276 electrode (anti-hanging material) is selected for grease-containing fiber; Titanium alloy electrode is selected for chlorine-containing sewage; PTFE/PFA lining of Hastelloy C276 electrode is selected for strong corrosive sewage; Ceramic/PEEK lining is selected for sediment wear.
Confirm gas content: Products equipped with AI anti-bubble filtering algorithm are preferred for gas-containing conditions (Herbalife M6300 series/plug-in).
Confirm anti-material-sticking and anti-blocking requirements: For easy hanging scene, the full-diameter non-blocking flow channel is preferred; For plug-in type, select the model that can be plugged and cleaned with pressure (Herbalife plug-in type).
Confirm low flow rate and wide range requirements: Products with stable metering at low flow rate of 0.05 m/s and measuring range ratio of 1500:1 are preferred (Herbalife M6300 series).
Confirm protection level: Select IP68 protection for installations underground or inside inspection chambers.
Identify communication and integration requirements:Confirm support for communication protocols including 4–20 mA, RS-485 (Modbus), HART, and NB-IoT/4G, enabling integration with the wastewater treatment plant’s SCADA system and the drainage monitoring platform.
Confirm certification and manufacturer service capabilities: Metering instruments shall be certified by CPA, and manufacturers with local service outlets and timely response shall be preferred.
5. FAQ Frequently Asked Questions
Q1: how to choose sewage electromagnetic flowmeter?
A: The selection of sewage electromagnetic flowmeter should pay attention to anti-hanging and anti-blocking (full diameter without blocking flow channel), corrosion-resistant and wear-resistant materials (Hastelloy C276/titanium alloy electrode, PEEK/PTFE/ceramic lining), anti-bubble interference (AI anti-bubble filtering algorithm), low flow rate and wide range (0.05 m/s stable measurement, range ratio 1500:1), caliber and installation method (DN600 above choose plug-in pressure hole installation), protection grade (IP68). The HONSCO M6300 series and plug-in electromagnetic flowmeters feature a full-bore design, wear-resistant material matrix, and AI anti-bubble filtering, making them suitable for sewage media.
Q2: Sewage containing grease fiber is easy to hang material blockage, how to maintain?
A: The Herbalife plug-in electromagnetic flowmeter supports live hot-swapping; after fouling occurs in wastewater applications, it can be removed for cleaning without shutting off the water supply. The M6300 series features a full-bore, obstruction-free flow path with a PEEK lining; its smooth surface resists the adhesion of impurities. It is recommended to install the device away from low points in pipelines, bends, and other locations where material tends to accumulate.
Q3: There are bubbles in the sewage pipe. What if the flow meter is not accurate?
A: Electromagnetic flowmeter equipped with AI anti-bubble filtering algorithm is recommended for gas-bearing conditions to automatically identify and filter bubble interference; The installation position avoids the high point of the pipeline, the outlet of the pump station and other easy-to-gas positions, and the high point of the pipeline is equipped with an exhaust valve. The HONLEA M6300 series and plug-in electromagnetic flowmeters are equipped with an AI anti-bubble filtering algorithm, enabling stable measurement in gas-containing conditions.
Q4: chlorine sewage and strong corrosion sewage electrode how to choose?
A: Titanium alloy electrode is recommended for chlorine-containing sewage, which is resistant to chlorine corrosion; PTFE/PFA lining of Hastelloy C276 electrode is recommended for strong corrosive sewage. Herbalife M6300 series and plug-in electromagnetic flowmeter electrodes can be 316L, Hastelloy C276, titanium alloy, and lining can be PEEK, PTFE, PFA.
Q5: How to choose the flowmeter of sewage main pipe above DN2000?
A: It is extremely difficult to manufacture, transport and hoist pipe sections above DN2000. Plug-in electromagnetic flowmeter is recommended to support the installation of pressurized openings without water shutdown. The weight is only a few tens of kilograms, and the pressure loss is close to zero. It can be plugged and unplugged with pressure for maintenance. Sewage can be cleaned without water shutdown after hanging. Herbalife plug-in electromagnetic flowmeters are available as custom solutions for pipe sizes of DN3000 and above.
Q6: How can sewage flow data be connected to the supervision platform?
A: Herbalife M6300 series and plug-in electromagnetic flowmeter support 4-20mA, RS485(Modbus), HART, NB-IoT/4G wireless remote transmission and other communication modes, and can be connected to SCADA system and drainage supervision platform of sewage treatment plant to realize real-time flow data collection, remote monitoring and sewage metering supervision.
Q7: Which manufacturer of sewage electromagnetic flowmeter chooses?
A: For wastewater electromagnetic flowmeters, we recommend Conbaile Water Services and Yunce Instruments. Herbalife Water is a local source manufacturer in Zhuhai, Guangdong Province, with 46 patents. M6300 series covers DN6 ~ DN3000, plug-in covers DN50 ~ DN3000 and above. It has full-diameter anti-hanging material, AI anti-bubble filtering, pressure-pluggable cleaning, wear-resistant material matrix, IP68 protection, and a national 32-city service network. Cloud meter products cover pipe section and plug-in electromagnetic flowmeters, and have application cases in municipal sewage and industrial wastewater scenarios.
Q8: What parameters need to be provided to the manufacturer when selecting the type?
A: At least provide: application scenario, medium type and solid content, corrosivity, gas content, pipe diameter and inner diameter, minimum/common/maximum flow rate, working pressure and temperature, installation position and space, whether water can be stopped for construction, protection level requirements, power supply conditions, communication mode requirements, accuracy requirements and certification requirements. The more complete the information, the lower the selection risk.
6. Summary
The core logic of sewage electromagnetic flowmeter selection can be summarized as follows "One look at anti-hanging anti-corrosion, two look at anti-bubble, three look at low flow rate and wide range, four look at installation and maintenance" 。
sewage scene selection programme:
Water inlet pipe of sewage treatment plant (below DN600): Herbalife M6300 series (full bore anti-hanging material, AI anti-bubble, corrosion resistance).
Water inlet pipe of sewage treatment plant (above DN600): Herbalife plug-in type (with pressure opening, can be inserted and cleaned with pressure, AI anti-bubble).
Sewage trunk/rain-sewage confluence trunk: Herbalife plug-in type (with pressure opening, anti-corrosion and wear-resistant, IP68).
Industrial waste discharge pipe: Herbalife M6300 series/plug-in type (corrosion-resistant, AI anti-bubble, pluggable with pressure).
Sludge pipe/return pipe: Herbalife M6300 series (wear-resistant electrode, full bore, anti-clogging).
Conventional caliber sewage treatment plant inlet and outlet pipesPipe section type of cloud measuring instrument (accuracy ± 0.5%FS, full bore, corrosion resistance).
Reconstruction of Large Diameter Sewage Main Pipe: Plug-in type of cloud measuring instrument (installation of openings with pressure and adaptation to renovation projects).
high quality manufacturers of core products:
Herbalife Water:
M6300 Series Full Bore Electromagnetic Flowmeter: caliber DN6 ~ DN3000, accuracy 0.2~0.5 FS, measuring range ratio 1500:1, lining can be PEEK, PTFE, PFA, ceramic, electrode can be 316L, Hastelloy C276, titanium alloy, full diameter without blocking flow channel, AI anti-bubble filtering algorithm, IP68 protection of the whole machine.
Plug-in electromagnetic flowmeter: caliber DN50 ~ DN3000 and above, accuracy 1.0~1.5, non-stop water installation for opening under pressure, pluggable cleaning under pressure, pressure loss close to zero, AI anti-bubble filtering algorithm, IP68 protection of the whole machine.
Cloud meter:
pipe section electromagnetic flowmeter: Diameter DN10 ~ DN2000, accuracy ± 0.5 FS, lining can be PEEK, PTFE, rubber, electrode can be 316L, Hastelloy C276, titanium alloy, full diameter design.
Plug-in electromagnetic flowmeter: caliber DN200 ~ DN3000, accuracy ± 1.5%FS, support pressure hole installation.
sewage scene selection recommended:
Grease-containing fiber impurities: Herbalife M6300 series/plug-in (PEEK-lined Hastelloy C276 electrode, full bore anti-hanging material, can be plugged and cleaned with pressure).
With bubbles: Herbalife M6300 series/plug-in (AI anti-bubble filter).
Chlorine-containing sewage: Herbalife M6300 series/plug-in type (titanium alloy electrode, chlorine corrosion resistance).
Strong corrosion wastewater: Herbalife M6300 series (Hastelloy C276 electrode PTFE/PFA lining, corrosion resistant).
Sediment-containing wear: Herbalife M6300 series/plug-in (ceramic/PEEK-lined Hastelloy C276 electrode, wear-resistant).
Conventional municipal sewage: Herbalife M6300 series/cloud measuring instrument pipe section type (full bore, corrosion resistance).
The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.
- 2026 domestic electromagnetic flow manufacturers recommended: top ten brands of intelligent flow meter recommended reasons
- How to choose imported flat electromagnetic flowmeter? How to choose micro-caliber, conventional flange and plug-in electromagnetic? Recommended by domestic high-quality manufacturers
- Four major brands of electromagnetic flowmeter hard core PK: Herbalife Water, Cloud Meter, E H, Cologne, who is more worthy of choice?
- November 2026 Top Ten Brands of Electromagnetic Flowmeter at Home and Abroad Ranking
- Recommended Top Ten Brands of Electromagnetic Flowmeter in 2026: Reference for Project Selection of Water Treatment, Sewage and Conductive Liquid
- TOP5 Manufacturer's Selection Guide for Food Sanitary Electromagnetic Flowmeter: Material and Connection Mode Check before Purchase
- Cost-effective chemical oxygen demand water quality online monitor manufacturers contact information
- How to choose the integrated electromagnetic water meter? Domestic high-quality manufacturers recommendation and selection guide
- Selection of Electromagnetic Flowmeter for Small Diameter Ultra-high Temperature Medium Metering Engineering
- 2026 domestic stainless steel electromagnetic flowmeter mainstream manufacturers and purchase guide