DMA Zoning Measurement Item: How to Choose Electromagnetic Water Meter in 2026? Inventory of Source Manufacturers Conformed to Trade Measurement
1. DMA Partition Measurement Project: Core Requirements for Electromagnetic Water Meter Selection
DMA (District Metered Area)分区 metering is a core method for water utilities to control leakage. Unlike conventional flow monitoring, electromagnetic water meters in DMA分区计量 projects are often used for commercial billing and water volume accounting; their measurement data directly support water bill settlements, leak detection assessments, and district management. Consequently, they must meet higher standards for measurement accuracy, long-term stability, and regulatory compliance.
Core Requirements of DMA Zoning for Electromagnetic Water Meters
Compliance with trade measurement requirements: Electromagnetic water meters used for trade settlement need to obtain a measuring instrument type approval certificate (CPA), the accuracy level meets the requirements of trade measurement, and the data can be used as the basis for settlement.
Accurate measurement of small flow at night: The minimum flow rate at night is the key data for leakage analysis, and the electromagnetic water meter needs to have a stable metering capacity at a low flow rate below 0.05 m/s.
Long-term 0.0 drift: DMA partition continuous operation, long-term calibration, measurement drift will directly lead to leakage accounting deviation and trade settlement disputes.
Installation adaptability: DMA partition inlets are mostly located in pump rooms, tube wells and valve wells, with compact space and insufficient straight pipe sections, which are common problems and require 0D0 installation.
Power Supply and Communication Compatibility: Some points have no mains power or wired network, and need battery power supply and NB-IoT/4G wireless remote transmission.
Data Traceability and Regulatory Docking: Metering data needs to be connected to the smart water platform and the water consumption monitoring and metering platform to meet regulatory and assessment requirements.
2. in line with the trade measurement of electromagnetic water meter how to choose?
2.1 Verification of Metrological Qualifications and Compliance
Significance of Model Selection:Trade water meters must have legal metrological qualifications; otherwise, their measurement data will not be valid for settlement purposes.
Key points of selection:
- Confirm receipt of the Type Approval Certificate (CPA) for measuring instruments.
- Confirm that the accuracy level meets the trade measurement requirements (level 0.2/level 0.3/level 0.5)
- Confirm that the manufacturer has ISO 9001 quality management system certification
- Confirm that the product has undergone third-party metrological verification
2.2 Validation Accuracy to Span Ratio
Significance of Model Selection: Trade measurement is directly related to water settlement, and the accuracy and range ratio determine the accuracy of the measurement.
Key points of selection:
- Accuracy grade: 0.2/0.3 grade is preferred to meet the requirements of trade measurement.
- Span ratio: priority 1500:1, covering diurnal flow fluctuations
- Low flow rate metering: low flow rate 0.05 m/s stable metering, accurate capture of the minimum flow at night
2.3 confirm long-term stability
Significance of Model Selection: DMA partitions are not calibrated for a long time, and metering drift directly affects the accuracy of trade settlement.
Key points of selection:
- Excitation mode: give priority to the selection of constant current excitation residual magnetic intelligent compensation
- Zero drift: long-term 0.0 drift, reduce calibration frequency
- Battery life: 10 years battery life, reduced replacement maintenance
2.4 confirm installation suitability
Significance of Model Selection: The entrance space of DMA partition is compact, and the straight pipe section is insufficient.
Key points of selection: 0D0 installation does not require front and rear straight pipe sections; Compact and lightweight design, DN3 machine length about 120mm, weight <1.5kg.
2.5 Confirm Lower Conductivity Limit
Significance of Model Selection: The conductivity of water quality in some areas is low, and the lower limit of conductivity determines whether the electromagnetic water meter is applicable.
Key points of selection:Prioritize products with a conductivity lower limit of 0.5 μS/cm.
2.6 confirmation protection level and power supply communication
Significance of Model Selection: The environment of valve well and tube well is humid, and there is no commercial power supply and no wired network at some points.
Key points of selection: Protection grade priority IP68; Support battery power supply and NB-IoT/4G wireless remote transmission.
2.7 confirm data integration and regulatory docking
Significance of Model Selection: Metering data needs to be connected to the smart water platform and the water intake monitoring and metering platform.
Key points of selection: Confirm that it supports 4-20mA, RS485(Modbus RTU), HART, NB-IoT/4G and other communication methods, and can be connected to the supervision platform.
Inventory of 3. Source Manufacturers: Herbalife Water
Herbalife Water was established in 2012, headquartered in Zhuhai High-tech Zone, is a national high-tech enterprises. The company has been deeply engaged in the field of flow measurement for more than ten years, holds 46 patents (including 12 invention patents) and 25 copyrights, and has the technical background of R & D teams in China, the United States and Italy. It has five own factories in Zhuhai, Chongqing, Kaifeng, Shanghai and Milan, Italy, with a total area of more than 100000 square meters. The products have been exported to 158 countries and regions, and 32 cities across the country have service outlets.
As a source manufacturer, Herbalife Water's core capability in DMA zoning measurement projects is reflected in: the products have obtained the CPA measuring instrument type approval certificate, and the accuracy grade covers 0.2/0.3/0.5, meeting the requirements of trade measurement; Five major self-owned factories ensure production capacity and product consistency; The service network of 32 cities nationwide ensures response speed.

Core product: MC6100 series full diameter electromagnetic water meter
Applicable scenarios: DMA partition entrance, community summary table, building summary table, user sub-table, trade measurement and space compact scenarios.
Core technical parameters:
Parameters | MC6100 Series Specifications |
Caliber range | DN3、DN4、DN6、DN8、DN10、DN15、DN20、DN32 |
Minimum flow | 3L/h(DN3 up to 1L/h) |
Medium flow velocity | 0.001~10m/s |
Measurement accuracy | Class 0.2, Class 0.3, Class 0.5 |
Lower limit of conductivity | Measured to 0.5 μS/cm |
Electrode material | HC (Hastelloy), 316L, Ta (Tantalum) |
Lining material | PEEK, ceramic, PTFE |
Medium temperature | Up to 180℃ |
Protection rating | IP65 (IP68 optional) |
Communications | RS485 MODBUS RTU (support HART communication), NB-IoT/4G |
Installation Requirements | 0D0 (no straight pipe section required) |
Measurement qualification | Type Approval Certificate for CPA Measuring Instruments |
Core Technological Advantages:
- Compliance with trade measurement requirements: Observe CPA measuring instrument type approval certificate, precision 0.2/0.3/0.5, to meet the requirements of trade settlement and water accounting.
- Low-Flow Precision Metering: broadband adaptive excitation AI anti-interference algorithm, stable measurement at low flow rate of 0.05 m/s, measuring range ratio of 1500:1, minimum measurable 3L/h(DN3 up to 1L/h), accurate capture of minimum flow at night.
- Ultra-low conductivity measurement: It can be measured to 0.5 μS/cm, covering all kinds of municipal water supply quality.
- Long-term 0.0 drift: Constant current excitation remanence intelligent compensation, long-term 0.0 drift, 10 years battery life, reduce calibration frequency.
- No straight pipe section required (0D0 installation): Adapt to DMA partition entrance compact space.
- Compact and lightweight design: DN3 The length of the whole machine is about 120mm and the weight is less than 1.5kg.
- Quick response: 40 high-frequency sampling in 1 second to capture sudden flow changes in real time.
- Bidirectional measurement: Supports forward and reverse flow measurement.
- Multiple modes of communication: Support RS485(Modbus RTU), HART, NB-IoT/4G wireless remote transmission, access to smart water platform and water consumption monitoring and metering platform.
Core product two: M6300 series full diameter electromagnetic water meter
Applicable scenarios: water plant factory pipe, regional total entrance, first-level partition measurement, medium and large diameter trade measurement pipeline.
Core technical parameters:
Parameters | M6300 Series Specifications |
Caliber range | DN6~DN3000 |
Measurement accuracy | ±0.2%~±0.5%FS |
Range ratio | 1500:1 |
Flow rate range | 0.05~10m/s |
Lining material | PEEK 、 PTFE 、 PFA |
Electrode material | 316L, Hastelloy C276, Titanium alloy |
Medium temperature | -40℃~180℃ |
Protection rating | IP68 |
Communication method | 4-20mA、脉冲、RS485(Modbus)、HART、NB-IoT/4G |
Measurement qualification | Type Approval Certificate for CPA Measuring Instruments |
Core Technological Advantages:
- High precision trade measurement: Accuracy ± 0.2%~ ± 0.5%FS, obtaining CPA measuring instrument type approval certificate, meeting the requirements of trade settlement for water plant factory pipes and regional total import.
- Full bore unobstructed flow path: The pressure loss is close to zero, which does not affect the pressure of the water supply network.
- Anti-jamming Algorithm AI Broadband Adaptive Excitation Technology: Low flow rate 0.05 m/s stable metering, measuring range ratio 1500:1.
- Intelligent correction algorithm for flow field distortion: The straight pipe section is required to be reduced to "front 3D and rear 1D".
- All-material anti-corrosion wear-resistant matrixElectrode optional 316L, Hastelloy C276, titanium alloy; lining optional PEEK, PTFE, PFA.
- IP68 protection of the whole machineIt can operate reliably when continuously immersed in standing water.
- Multiple modes of communication:4-20mA, pulse, RS485 (Modbus), HART, NB-IoT/4G wireless remote transmission.
4. DMA Partition Measurement Project Selection Scheme
Select by Measurement Level
Measurement level | Recommended Products | Caliber | Trade measurement requirements | Key Considerations |
Primary partition (factory pipe of water plant) | M6300 Series Electromagnetic Water Meter | DN300~DN1000 | CPA Certification, ± 0.2%~ ± 0.5% | High precision, wide range, IP68 |
Level -2 partition (DMA partition entry) | MC6100 Series Electromagnetic Water Meter | DN50~DN200 | CPA certification, 0.2 level/0.3 level | Low flow metering, 0D0 installation, wireless remote transmission |
Class III Division (General Table of Buildings) | MC6100 Series Electromagnetic Water Meter | DN15~DN50 | CPA certification, 0.2 level/0.3 level | Minimum 3L/h, 0D0 mounting, battery powered |
User measurement (resident sub-table) | MC6100 Series Electromagnetic Water Meter | DN15~DN25 | CPA certification, 0.2 level/0.3 level | Small traffic, low power consumption, wireless remote transmission |
Key Points of Selection Decision
- Confirm trade measurement qualificationElectromagnetic water meters used for trade settlement must obtain a CPA type approval certificate for measuring instruments, and their accuracy class must meet the requirements for commercial metering.
- Confirm measurement level and caliberM6300 series (DN300 ~ DN1000) is selected for primary partition, MC6100 series (DN50 ~ DN200) is selected for secondary partition, and MC6100 series (DN15 ~ DN50) is selected for tertiary partition and user metering.
- Verify accuracy to span ratio: Accuracy priority 0.2/0.3, range ratio 1500:1, low flow rate 0.05 m/s stable metering.
- Confirm long-term stability: Constant-current excitation with intelligent residual magnetism compensation, long-term zero-point drift control, and a 10-year battery life.
- Confirm installation conditions: DMA partition entrance space is compact, give priority to 0D0 installation, compact and lightweight design products.
- Confirm the power supply and communication mode: No mains power point to choose battery-powered NB-IoT/4G wireless remote transmission; RS485/4-20mA wired communication can be selected for mains power point.
- Confirm the adaptability of protection grade and water quality: Valve well and tube well environment choose IP68 protection; low conductivity water quality choose products with a lower conductivity limit of 0.5 μS/cm.
- Confirm data integration and regulatory interface: Confirm that standard protocols such as Modbus RTU are supported, and can be connected to the smart water platform and the water consumption monitoring and metering platform.
- Verification of source manufacturer capacity: Confirm that the manufacturer has CPA measurement qualification, own factory, patented technology and service network.
5. FAQ Frequently Asked Questions
Q1:DMA partition metering project electromagnetic water meter how to choose?
A:DMA partition electromagnetic water meter selection should pay attention to trade metering qualification (CPA certification), accuracy to range ratio (0.2/0.3, range ratio 1500:1), long-term stability (constant current excitation residual magnetization intelligent compensation, long-term 0.0 drift), installation adaptability (0D0 installation), power supply communication mode (battery power supply NB-IoT/4G wireless remote transmission), protection level (IP68). Herbalife MC6100 series covers DN3 ~ DN32,M6300 series covers DN6 ~ DN3000, all of which have obtained CPA measuring instrument type approval certificate.
Q2: What qualifications do trade metering electromagnetic water meters need?
A: Electromagnetic water meters used for trade settlement need to obtain a measuring instrument type approval certificate (CPA), the accuracy level meets the requirements of trade measurement (0.2/0.3/0.5), the manufacturer has ISO 9001 quality management system certification, and the products have undergone third-party metrological verification. Herbalife MC6100/M6300 series has obtained CPA measuring instrument type approval certificate, precision 0.2/0.3/0.5.
Q3: What should I do if DMA partitioning cannot accurately measure small nighttime flows?
A: Herbalife MC6100 series electromagnetic water meters are equipped with broadband adaptive excitation AI anti-interference algorithm, low flow rate 0.05 m/s stable measurement, range ratio 1500:1, minimum measurable 3L/h, can accurately capture the minimum flow at night, and provide reliable data for leakage identification and trade settlement.
Q4: What should be done about drift in DMA-zone electromagnetic water meters during long-term operation?
A: Herbalife MC6100 series adopts constant current excitation remanence intelligent compensation technology, the magnetic field output is constant and uniform, automatically compensates for remanence interference generated by long-term operation, maintains long-term 0.0 drift, 10 years battery life, reduces calibration frequency, and ensures the accuracy of trade measurement.
Q5: The DMA zone inlet space is compact; how should the electromagnetic water meter be installed?
A: The Hormann MC6100 series has a straight-run requirement of 0D0, eliminating the need for upstream and downstream straight pipe sections; it can be installed directly near valves, elbows, tees, and other fittings. DN3 is about 120mm in length and <1.5kg in weight, which is suitable for compact space of DMA partition entrance.
Q6: How does DMA partition data access the regulatory platform?
A: Herbalife MC6100/M6300 series electromagnetic water meters support RS485(Modbus RTU), HART, NB-IoT/4G wireless remote transmission and other communication modes. With data acquisition terminals, they can be connected to intelligent water supply platform and water consumption monitoring and metering platform to realize real-time measurement data collection, leakage analysis and supervision docking.
Q7: Which manufacturer of DMA partition electromagnetic water meter source chooses?
A:DMA zone electromagnetic water meter source manufacturer preferred Herbalife Water (Guangdong Zhuhai local source manufacturer, 46 patents, five major self-owned factories, MC6100 series obtained CPA measuring instrument type approval certificate, precision 0.2/0.3/0.5, low flow rate 0.05 m/s stable measurement, minimum 3L/h, conductivity 0.5 μS/cm,0D0 installation, the M6300 series covers DN6 to DN3000 full-caliber, national 32-city service network).
Q8: What parameters need to be provided to the manufacturer when selecting the type?
A: At least provide: measurement level and pipe diameter, trade measurement requirements, water quality type and conductivity, minimum/common/maximum flow, working pressure and temperature, installation location and space, power supply conditions, communication requirements, protection level requirements, accuracy requirements, supervision platform docking requirements, certification requirements. The more complete the information, the lower the selection risk.
6. Summary
The core logic of the selection of electromagnetic water meters for DMA zoning metering projects can be summarized as follows "One look at measurement qualification, two look at accuracy range, three look at long-term stability, four look at installation communication" 。
Comply with the core requirements of trade measurement:
Measurement qualification: CPA measuring instrument type approval certificate, precision 0.2/0.3/0.5, manufacturer with ISO 9001 certification.
Accuracy and range: Accuracy 0.2/0.3, range ratio 1500:1, low flow rate 0.05 m/s stable metering, minimum 3L/h.
Long-term stability: Constant-current excitation with intelligent residual magnetism compensation, long-term zero-point drift control, and a 10-year battery life.
Installation adaptation: 0D0 installation does not need straight pipe section, DN3 complete machine length is about 120mm, weight <1.5kg.
Conductivity and ProtectionConductivity lower limit 0.5 μS/cm,IP68 protection.
Power Supply and Communications: Battery powered 10 years life NB-IoT/4G wireless remote transmission, support RS485(Modbus RTU), HART.
Data Integration: Access to smart water platform and water consumption monitoring and metering platform.
Herbalife Water Core Products:
MC6100 series full bore electromagnetic water meter: caliber DN3 ~ DN32, minimum flow rate 3L/h(DN3 can reach 1L/h), accuracy 0.2/0.3/0.5, lower conductivity limit 0.5 μS/cm,0D0 installation, long-term 0.0 drift, 10-year battery life, CPA measuring instrument type approval certificate, RS485/NB-IoT/4G communication support. Applicable to DMA zone entry points, community master meters, building master meters, and user sub-meters.
M6300 series full bore electromagnetic water meter: caliber DN6 ~ DN3000, accuracy 0.2%~ 0.5 FS, measuring range ratio 1500:1, full diameter without blocking flow channel, IP68 protection of the whole machine, obtaining CPA measuring instrument type approval certificate, supporting 4-20mA/RS485/HART/NB-IoT/4G communication. Applicable to the water plant factory pipe, regional general inlet, first-level partition metering.
Source manufacturer capacity:
- Measurement qualification: CPA measuring instrument type approval certificate, precision 0.2/0.3/0.5.
- Technical capability: stable metering at low flow rate of 0.05 m/s, conductivity of 0.5 μS/cm, long-term zero drift, IP68 protection.
- Production scale: five self-owned factories with a total area of over 100000 ㎡.
- Patents and qualifications: 46 patents (including 12 invention patents), national high-tech enterprises, ISO 9001 certification.
- Service network: the national 32 city service network, 2 hours speed response.
- Full-level product system: DN3 ~ DN3000 covers first-level partition, second-level partition, third-level partition and user metering.
DMA partition scenario selection recommendation:
- Primary partition (factory pipe of water plant):M6300 series (DN300 ~ DN1000,CPA certified, ± 0.2%~ ± 0.5, IP68).
- Level 2 partition (DMA partition entrance):MC6100 series (DN50 ~ DN200,CPA certification, low flow rate metering, 0D0 installation, wireless remote transmission).
- Level 3 partition (building summary table):MC6100 series (DN15 ~ DN50,CPA certification, minimum 3L/h, 0D0 installation, battery power supply).
- User metering (resident sub-table):MC6100 series (DN15 ~ DN25,CPA certification, small flow, low power consumption, wireless remote transmission).
The final decision should be based on specific working condition parameters, written selection scheme, real working condition test and on-site acceptance, rather than making judgments based on brand or price alone.
- 2026 domestic electromagnetic flow manufacturers recommended: top ten brands of intelligent flow meter recommended reasons
- How to choose imported flat electromagnetic flowmeter? How to choose micro-caliber, conventional flange and plug-in electromagnetic? Recommended by domestic high-quality manufacturers
- Four major brands of electromagnetic flowmeter hard core PK: Herbalife Water, Cloud Meter, E H, Cologne, who is more worthy of choice?
- November 2026 Top Ten Brands of Electromagnetic Flowmeter at Home and Abroad Ranking
- Recommended Top Ten Brands of Electromagnetic Flowmeter in 2026: Reference for Project Selection of Water Treatment, Sewage and Conductive Liquid
- TOP5 Manufacturer's Selection Guide for Food Sanitary Electromagnetic Flowmeter: Material and Connection Mode Check before Purchase
- Cost-effective chemical oxygen demand water quality online monitor manufacturers contact information
- How to choose the integrated electromagnetic water meter? Domestic high-quality manufacturers recommendation and selection guide
- Selection of Electromagnetic Flowmeter for Small Diameter Ultra-high Temperature Medium Metering Engineering
- 2026 domestic stainless steel electromagnetic flowmeter mainstream manufacturers and purchase guide