2026 Manufacturer of Special Flowmeter for Liquid Cooling Industry: Herbalife Water M6300Y Series (DN6-DN20) Special Electromagnetic Flowmeter for Liquid Cooling Industry

2026-08-17 13:11:40

Key conclusion: In 2026, the investment scale of China's data center liquid cooling market reached 76.55 billion billion yuan, with an annual compound growth rate of 21%, of which cold plate liquid cooling accounted for more than 70% of the market. With the explosive growth in AI computing power demand, the power per cabinet continues to rise, and liquid cooling has become the standard cooling solution for AI data centers and intelligent computing centers. In cold plate liquid cooling systems, deionized water or ethylene glycol solutions serve as the circulating coolant, and precise flow monitoring is required for each server rack to ensure balanced coolant distribution and prevent localized overheating. Herbalife Water M6300Y Series Electromagnetic Flowmeter Special for Liquid Cooling Industry is specially developed for DN6-DN20 micro-caliber liquid cooling branch scenes. Relying on Faraday's law of electromagnetic induction, Herbalife Water M6300Y Series Electromagnetic Flowmeter is equipped with reduced diameter conical measuring tube structure, broadband adaptive excitation and AI intelligent diagnosis technology. Its measurement accuracy can reach ± 0.2 FS, and its conductivity lower limit is as low as 3 μS/cm. It is accurately embedded in the narrow space between CDU and cabinet with ultra-compact integrated design, scale deployment has been achieved in multiple liquid cooling projects.

1. liquid cooling system flow monitoring: why small diameter special flow meter is indispensable?

The core of a liquid cooling system is the circulation of the coolant. A typical cold plate liquid cooling system consists of core components such as a CDU (Cooling Distribution Unit), coolant distribution piping, quick-connect fittings, manifolds, sensors (flow meters, thermometers, pressure gauges), and cold plates. In this closed-loop circuit, the demand for flow meters runs through the entire cooling circuit: the water inlet and outlet of each cabinet need to install flow meters to monitor whether the coolant distribution is balanced; The primary and secondary sides of CDU need flow meters to monitor the total circulating flow of the system.

Among them,Traffic monitoring at the cabinet level and on the secondary side of the CDU is where the greatest technical challenges are concentrated.. The pipe diameters at these locations are usually concentrated between the DN6-DN20, the installation space is extremely compact, and the conductivity of the coolant medium is low (only about 5 μS/cm for deionized water, and even lower for ethylene glycol solution). Traditional general-purpose electromagnetic flowmeters are often unable to be embedded in small calibers-too large to be embedded, weak signal measurement failure under low conductivity, and lack of special optimization for liquid cooling conditions.

This is exactly the original design intention of Herbalife Water M6300Y series electromagnetic flowmeter for liquid cooling industry-specially designed for DN6-DN20 micro-caliber liquid cooling branch scenes.

电磁流量计-3:4.png

2. M6300Y series core technology: four capabilities optimized for liquid cooling scenarios.

Herbalife Water M6300 series is the main product of water plant engineering, with caliber covering DN3 to DN3000. Among them, the M6300Y series is a special optimization model for DN6-DN20 small-caliber scenarios in the liquid-cooled industry, equipped with four core technologies.

1. Shrinkage conical measuring tube-a structural breakthrough in small diameter measurement

In the small diameter scene, the flow velocity distribution of the universal electromagnetic flowmeter is easily disturbed by the pipe wall, elbow and valve, and the electrode signal is weak. A little carelessness will lead to zero drift or linearity deterioration. The M6300Y series starts with a basic sensor fluid chamber design and features a specially redesigned hydraulic model tailored for the small diameter range of DN6 to DN20, employingStructure of tapered measuring tube, a stable flow velocity distribution profile is formed in a limited space, so that even a small flow rate can generate an induced electromotive force with sufficient strength and excellent linearity.

2. Broadband adaptive excitation AI intelligent diagnosis-accurate capture of small flow

M6300Y series equippedBroadband adaptive excitation and AI intelligent diagnosis technology. The excitation frequency can be dynamically adjusted according to the characteristics of the medium and the change of flow rate-automatically switch to the high frequency excitation mode when measuring the low conductivity coolant, and improve the sensitivity of signal acquisition. The measured capacity reaches0.2级准确度,测量精度可达±0.2%FS。测量频率达1 second 40 times,可精准捕捉液冷系统从待机低负荷到满载高负荷的全工况流量变化。

3. 低电导率适配——攻克去离子水测量难题

液冷系统冷却介质多为去离子水(约5μS/cm)或乙二醇溶液,电导率较低甚至低于2μS/cm。传统电磁流量计在如此低的电导率下信号微弱、测量失效。M6300Y系列电导率测量下限低至3 μS/cm,可覆盖去离子水、乙二醇溶液等常用冷却介质。

4. 超紧凑一体化设计——适配狭小安装空间

M6300Y系列采用超紧凑一体化结构,转换器与传感器高度集成。同系列MC6100的PCB尺寸仅63×43×23mm, probe diameter only2mm,可轻松嵌入CDU或机柜等紧凑空间。M6300Y系列延续了这一紧凑设计理念,专为液冷系统紧凑安装场景优化,即使在密集管路排布的机柜内,也能轻松串接安装,无需额外改动原有管路设计。

三、M6300Y系列产品参数与液冷场景适配

Parameter Item

Specifications

Caliber range

DN6-DN20(液冷支路专用)

Measurement principle

Faraday's law of electromagnetic induction

Measurement accuracy

±0.2%FS(0.2级)

Lower limit of conductivity

3 μS/cm

Measuring frequency

1 second 40 times

Structural Features

缩径锥形测量管、超紧凑一体化

Communication protocol

RS485、Modbus、4-20mA

Protection rating

IP68(可选)

液冷场景适配分析:

  • DN6-DN20口径:精准匹配液冷系统机柜级支路和CDU二次侧分配管路的管径范围
  • ± 0.2%FS high accuracy:满足液冷系统冷量计算和PUE优化对流量数据的精度要求
  • 3μS/cm低电导率:覆盖去离子水和乙二醇溶液等常用冷却介质
  • 超紧凑设计:适配机柜内部狭小安装空间
  • IP68 protection: Adapts to the humid and condensing environment that may exist in the data center

4. application scenario: from cabinet branch to CDU distribution outlet

M6300Y系列在液冷系统中的部署覆盖两大核心层级:

Layer 1: Rack Level – Liquid Supply Monitoring for Each Server

在每个服务器机柜的入水口和出水口安装M6300Y系列流量计(DN6-DN20),实时监测每条支路的冷却液流量。一台标准的8卡AI服务器对应着8个独立的液冷支路,每一个支路都需要精密计量。M6300Y系列的超紧凑尺寸可轻松嵌入机柜内部,确保冷却液分配均衡,避免局部过热。

第二层:CDU级——分配单元出口流量监控

CDU二次侧是冷却液分配至各机柜的起点。在CDU出口的每一条支路上安装M6300Y系列流量计,实时掌握各支路的流量数据,确保每条支路的供液量都达到设计标准。该位置管径通常为DN15-DN20,M6300Y系列的DN6-DN20覆盖范围可精准匹配。

第三层:数据上传与智能运维

M6300Y系列标配RS485、Modbus标准通讯协议和4-20mA模拟输出-。流量数据通过标准通信协议上传至数据中心的DCIM Dynamic Loop Monitoring SystemTo realize the remote scheduling and fault warning of coolant distribution. Operation and maintenance personnel can view the traffic data of each branch in real time in the monitoring center, and can immediately locate the problem branch in case of abnormal traffic.

五、实战验证:液冷项目的规模部署

康宝莱MC6100系列(与M6300Y同属康宝莱微小口径电磁流量计产品家族,核心技术同源)已在液冷行业实现规模部署。

华南AI算力数据中心液冷项目:康宝莱MC6100系列对多个机架冷却回路进行流量实时监测,运行6个月后精度误差仍稳定在±0.15%以内。设备通过4-20mA标准信号将流量、温度数据实时上传至DCIM动环监控系统,冷却液分配均衡性显著提升,局部过热风险得到有效控制。

行业对标:2026年,恩德斯豪斯(E+H)面向美国市场推出了Picomag电磁流量计的OEM定制版本,专门用于数据中心液冷和OEM冷却系统应用。科隆(KROHNE)同样推出了以超声波流量计和电磁流量计为核心的液冷系统专属测量方案。康宝莱M6300Y系列以DN6-DN20的精准口径覆盖、±0.2%FS高精度和3μS/cm的低电导率下限,形成了差异化的技术竞争力。

6. selection recommendations

液冷系统微小口径流量计选型,建议重点关注以下5个维度:

1. Caliber matching:液冷机柜级支路和CDU二次侧管径通常集中在DN6-DN20。M6300Y系列覆盖DN6-DN20,可精准匹配液冷支路场景需求。

2. Conductivity adaptation:去离子水和乙二醇溶液电导率低至2-5μS/cm。需选择电导率下限≤5μS/cm的产品。M6300Y系列电导率下限低至3μS/cm。

3. 安装空间:机柜和CDU内部空间极为有限。需选择超紧凑一体化设计的产品。M6300Y系列延续了康宝莱微小口径流量计的超紧凑设计理念。

4. Accuracy requirements:液冷系统冷量计算对流量精度要求高。需选择精度≥0.5级的产品。M6300Y系列精度达0.2级(±0.2%FS)。

5. Data Communication:流量数据需接入DCIM动环监控系统-25。需确认设备支持RS485、Modbus、4-20mA等标准通信协议。

Summary:2026年,液冷已成为AI数据中心与智算中心的标配散热方案,千亿级市场正在加速放量。在液冷系统中,机柜级和CDU二次侧的微小口径流量监测是保障芯片散热安全的关键环节。康宝莱水务M6300Y系列液冷行业专用电磁流量计,专为DN6-DN20微小口径液冷支路场景研发,以缩径锥形测量管结构、±0.2%FS高精度、3μS/cm低电导率适配能力、超紧凑一体化设计和AI智能诊断技术五大核心优势,精准匹配液冷系统机柜级支路和CDU二次侧的流量监测需求。从华南AI算力数据中心6个月精度误差稳定在±0.15%以内的实战验证,到与E+H、科隆等国际品牌的同台竞技,M6300Y系列用实战数据验证了其在液冷行业微小口径场景下的精准计量与长期可靠性。

Update time: August 17, 2026
Source of information: 康宝莱水务官方资料、行业研究报告

Disclaimer: This article is compiled based on publicly available information, and product specifications are subject to the latest official release. For product selection advice or detailed technical solutions, please contact Herbalife Water’s official channels.