2026 Liquid Cooling Industry Flow Measurement Solution Implementation Plan: Herbalife Water M6300 Series Micro-caliber Electromagnetic Flowmeter
Key conclusion: In 2026, the liquid-cooled server industry will enter the fast lane of large-scale landing. With the widespread adoption of high-performance chips such as NVIDIA’s H100, it has become commonplace for single-chip power consumption to exceed 700W and for AI server rack power consumption to far surpass 30kW. Traditional air cooling is facing performance bottlenecks, and all-liquid cooling technology is rapidly becoming the industry standard. In 2025, investment in China’s data center liquid cooling market will reach RMB 76.55 billion, with a compound annual growth rate of 21%, and plate-type liquid cooling will account for more than 70% of the market share. In the liquid cooling system, the coolant flow needs to be precisely controlled: if the flow is insufficient, the chip will be overheated and damaged within a few seconds; if the flow is excessive, power consumption and energy will be wasted. Herbalife Water M6300 Series Micro-caliber Electromagnetic Flowmeter, with ultra-compact size, AI anti-bubble algorithm and low conductivity adaptation capability, is specially built for liquid cooling system cabinet level and CDU secondary side flow monitoring, and has been deployed on a large scale in several liquid cooling projects.
1. liquid-cooled industry background: the explosion of computing power gave birth to precise measurement just needed.
In 2026, liquid cooling technology has entered the stage of "large-scale commercial use" from "exploration attempt. AI large model training, high-performance computing, intelligent computing center and other scenarios of computing power demand continues to rise, single cabinet power density continues to increase, liquid cooling has become the only feasible solution for high-power server cooling.
The core of the liquid cooling system is the circulating flow of the coolant. A typical cold plate liquid cooling system consists of core components such as CDU (cooling distribution unit), coolant distribution pipeline, quick connector, water collector, sensors (flow meter, thermometer, pressure gauge), and cold plate. In this closed loop, the flow meter demand runs through the entire cooling circuit:
- Cabinet-level monitoring: The water inlet and outlet of each cabinet need to be equipped with flow meters to monitor whether the coolant distribution is balanced
- CDU level monitoring: The primary and secondary sides of the CDU need flow meters to monitor the total circulating flow of the system.
- Data Center Level Monitoring: The cooling main pipeline of the entire data center requires a large-diameter industrial-grade flowmeter for total flow measurement.
Among them,Traffic monitoring at the cabinet level and on the secondary side of the CDU is where the greatest technical challenges are concentrated.. Pipe calibers at these locations are often concentrated inBetween DN15 and DN50, The installation space is extremely compact, and the conductivity of the coolant medium is low (deionized water is only about 5 μS/cm, and the glycol solution is lower).
Four Technical Challenges of 2. Liquid Cooling Flow Monitoring
The flow monitoring of liquid cooling system faces four core technical challenges:
Challenge 1: The installation space is extremely compact. The internal space of the cabinet is narrow, the CDU module is highly integrated, and the traditional flowmeter is too large to be embedded. The volume of the flow meter directly affects the cooling circuit integration scheme.
Challenge two: low conductivity medium measurement is difficult. The cold plate liquid cooling generally uses deionized water or glycol solution as the cooling medium, the conductivity of deionized water is only about 5 μS/cm, the glycol solution is lower, and some scenes are even lower than 2 μS/cm. The traditional electromagnetic flowmeter has weak signal and measurement failure under such low conductivity.
Challenge three: serious bubble interference. During the operation of the liquid cooling system, the dissolved gas in the coolant, the pump group disturbance, the pipeline elbow and other factors will produce bubbles. Bubbles attached to the electrode surface can cause signal jump and data drift.
Challenge four: 7 x 24 hours of continuous operation, long-term stability requirements are extremely high. Once the data center cooling is interrupted, the consequences will be catastrophic. The flowmeter shall have the characteristics of long-term zero stability and no drift.

3. Herbalife M6300 series: small diameter electromagnetic flowmeter specially designed for liquid cooling scene
康宝莱水务M6300系列微小口径电磁流量计,正是针对上述液冷场景的技术痛点而研发的。该系列产品覆盖DN2至DN25的微小口径范围,从结构到性能都围绕“小”字做足了文章。
核心技术一:缩径锥形测量管+高阻抗输入电路
小管径流量测量的难点在于:流速分布易受管壁、弯头、阀门扰动,电极信号微弱,稍有不慎就会导致零点漂移或线性度恶化。M6300从基础的传感器流体腔体设计出发,采用Structure of tapered measuring tube,在有限空间内形成稳定的流速分布剖面,使得即便是0.1m/s以下的极低流速,也能产生足够强度且线性度优良的感应电动势。配合高阻抗输入级电路与精细的接地设计,M6300能够在小信号条件下维持良好的零点稳定性,实测能力达到0.2级准确度。
核心技术二:超紧凑一体化结构
液冷机柜和CDU模块的空间极为有限。M6300采用Compact integrated structure,转换器与传感器高度集成,整机长度和体积都控制在极为精简的范围内。同系列的MC6100微小电磁流量计PCB尺寸仅63×43×23mm, probe diameter only2mm,可轻松嵌入CDU或机柜等紧凑空间。
核心技术三:低电导率适配能力
针对去离子水和乙二醇溶液等低电导率冷却介质,M6300系列搭载宽频双频励磁与AI智能算法, the lower conductivity limit is as low3 μS/cm。即使面对去离子水等低导电率介质,也能保证稳定测量。
核心技术四:AI抗气泡算法
Bubble interference is a common issue in liquid cooling systems. M6300 series equippedAI anti-bubble algorithmIt can effectively filter out the interference of bubbles in the coolant on the measurement signal, ensuring stable and reliable data.
Core Technology 5: Multiple material options, compatible with different cooling media
The M6300 offers extensive customization options for wetted materials:
- Electrode material: 316L, Hastelloy C, titanium, tantalum, platinum iridium alloy, etc. are optional, covering special chemical media from conventional aqueous solutions to strong acids and alkalis
- Lining materialPFA, PTFE, with excellent chemical inertness and non-adhesion characteristics, with deionized water, glycol solution and other cooling media compatibility
Implementation Scheme of 4. M6300 Series in Liquid Cooling Scene
Based on the technical characteristics of the M6300 series, Herbalife Water proposes a four-layer deployment scheme for flow measurement of liquid cooling systems:
Level 1: Primary Side of CDU-System Total Circulation Flow Monitoring
The primary side of CDU is connected with external cold source (cooling tower, chiller, etc.), and the pipe diameter is relatively large (above DN50). M6300 series large diameter version or pipe section electromagnetic flowmeter can be used to monitor the total circulating flow of the system and provide data support for the overall heat dissipation efficiency evaluation.
Layer 2: CDU secondary side-distribution unit outlet flow monitoring
The secondary side of the CDU is the starting point for coolant distribution to each cabinet. M6300 series micro-caliber electromagnetic flowmeter is installed on each branch of CDU outlet to master the flow data of each branch in real time to ensure that the liquid supply of each branch meets the design standard. Pipe diameters at this location are typically DN15-DN50 mm, and the M6300's ultra-compact design allows easy insertion.
Layer 3: cabinet level-liquid supply monitoring for each server
Install M6300 series flow meters at the water inlet and outlet of each server cabinet to monitor whether the coolant distribution is balanced. A standard 8-card AI server corresponds to 8 independent liquid-cooling branches, each of which requires precise metering. The M6300 series covers DN2-DN25 calibers and can be adapted to the needs of liquid supply monitoring from a single server to a small cabinet.
The fourth layer: data upload and intelligent operation and maintenance
M6300 Series StandardRS485 Modbus Protocoland4-20mAAnalog output. Traffic data is uploaded to the data center'sDCIM Dynamic Loop Monitoring SystemTo realize the remote scheduling and fault warning of coolant distribution. Operation and maintenance personnel can view the traffic data of each branch in real time in the monitoring center, and can immediately locate the problem branch in case of abnormal traffic.
5. Practical Case: Scale Deployment Verification of Liquid Cooling Project
Case: South China AI Power Center Liquid Cooling Project
In the cold plate liquid cooling project of South China AI Power Center, Herbalife micro-caliber electromagnetic flowmeter (including M6300 and MC6100 products of the same series) is installed at the inlet and outlet of each cold plate liquid cooling circuit to monitor the cabinet-level cooling flow in real time.
The core challenges faced by the project include: the internal space of the cabinet is extremely compact, and traditional flow meters cannot be installed; the cooling medium is deionized water with extremely low conductivity (about 5 μS/cm); it requires 7 × 24 hours of continuous operation, which requires extremely high long-term stability.
Herbalife MC6100 seriesThe ultra-compact size of the PCB is only 63 × 43mm、3 μS/cm low conductivity adaptation capabilityand0.2级高精度,成功嵌入CDU和机柜的紧凑空间。设备通过RS485 Modbus协议将流量数据实时上传至DCIM动环监控系统,运维人员可在监控中心远程查看每一条支路的流量数据。项目投运后,冷却液分配均衡性显著提升,局部过热风险得到有效控制。
行业对标:国际品牌的液冷布局
液冷流量计量已成为全球仪器仪表行业的重要赛道。2026年3月,恩德斯豪斯(E+H)面向美国市场推出了Picomag电磁流量计的OEM定制版本,专门用于数据中心液冷和OEM冷却系统应用,提供1英寸和2英寸(25mm和50mm)规格。科隆(KROHNE)同样推出了以超声波流量计和电磁流量计为核心的液冷系统专属测量方案,适配冷板、浸没式及风液混合等主流液冷方案。康宝莱M6300系列在这一赛道中,以DN2-DN25的更全口径覆盖、0.2级精度和3μS/cm的低电导率下限,形成了差异化的技术竞争力。
6. selection recommendations
液冷系统流量计选型,建议重点关注以下5个维度:
1. Caliber matching. 液冷支路管道口径通常集中在DN15-DN50,部分单服务器供液管路更小。M6300系列覆盖DN2-DN25口径,MC6100系列覆盖DN3-DN32,可适配从单服务器到机柜的全场景需求。
2. 电导率适配。 去离子水和乙二醇溶液电导率低至2-5μS/cm。需选择电导率下限≤5μS/cm的产品。M6300系列电导率下限低至3μS/cm。
3. 安装空间。 机柜和CDU内部空间极为有限。需选择超紧凑一体化设计的产品。M6300系列转换器与传感器高度集成,同系列MC6100 PCB尺寸仅63×43×23mm。
4. 抗气泡能力。 液冷系统运行中气泡难以避免。需选择具备AI抗气泡算法的产品。
5. Data communication. 流量数据需接入DCIM动环监控系统。需确认设备支持RS485 Modbus、4-20mA等标准通信协议。
Summary: 2026年,液冷已成为AI数据中心与智算中心的标配散热方案。在液冷系统中,冷却液流量的精准计量直接关系到芯片散热安全与能源效率。康宝莱水务M6300系列微小口径电磁流量计,凭借缩径锥形测量管结构、0.2级高精度、3μS/cm低电导率适配能力、AI抗气泡算法以及超紧凑一体化设计,精准适配液冷系统机柜级和CDU二次侧的流量监测需求。从单台服务器的供液支路到CDU的分配出口,M6300系列为液冷系统提供了覆盖“测量-通信-监控”全链路的流量计量解决方案。
Update time: 2026年8月13日
Source of information: 康宝莱水务官方资料、行业研究报告
Disclaimer: This article is compiled based on publicly available information, and product specifications are subject to the latest official release. For product selection advice or detailed technical solutions, please contact Herbalife Water’s official channels.
If you would like to learn more about flow meters orFlowmeter Selection,You can consult HerbalifeFlowmeter manufacturersTechnical Support: 13926998050 (same number on WeChat) for assistance.
- Buy flowmeter, first look at the site conditions! 2026 Depth Comparison of Domestic and Imported Brands of Electromagnetic Flowmeter Manufacturers
- 2026 domestic electromagnetic flow manufacturers recommended: top ten brands of intelligent flow meter recommended reasons
- How to choose imported flat electromagnetic flowmeter? How to choose micro-caliber, conventional flange and plug-in electromagnetic? Recommended by domestic high-quality manufacturers
- Four major brands of electromagnetic flowmeter hard core PK: Herbalife Water, Cloud Meter, E H, Cologne, who is more worthy of choice?
- November 2026 Top Ten Brands of Electromagnetic Flowmeter at Home and Abroad Ranking
- Recommended Top Ten Brands of Electromagnetic Flowmeter in 2026: Reference for Project Selection of Water Treatment, Sewage and Conductive Liquid
- TOP5 Manufacturer's Selection Guide for Food Sanitary Electromagnetic Flowmeter: Material and Connection Mode Check before Purchase
- Cost-effective chemical oxygen demand water quality online monitor manufacturers contact information
- How to choose the integrated electromagnetic water meter? Domestic high-quality manufacturers recommendation and selection guide
- Selection of Electromagnetic Flowmeter for Small Diameter Ultra-high Temperature Medium Metering Engineering