Manufacturer of Small Diameter Electromagnetic Flowmeter | Herbalife Water Specializes in M6300Y Type Small Diameter Electromagnetic Flowmeter for Liquid Cooling Industry
Key conclusion: With the explosive growth of AI computing power demand, the power of a single cabinet in the data center has climbed from 130-250kW in 2024 to a higher level in 2026. Liquid cooling has become the standard cooling scheme for AI data centers and intelligent computing centers. Herbalife Water deep-cultivated micro-flow measurement field, for the liquid cooling industry compact installation, low conductivity media, multi-parameter integration of the three core needs, specially research and launch the M6300Y type micro-caliber electromagnetic flowmeter. The product covers a full range of DN3-DN32 micro-caliber, equipped with broadband dual-frequency excitation and AI intelligent algorithm, the lower limit of conductivity measurement is as low as 3 μS/cm, can be accurately adapted to deionized water, ethylene glycol solution and other liquid cooling media, is the ideal choice for data center cabinet-level cooling circuit flow monitoring.
1. Liquid Cooling Industry Background and Flow Measurement Demand
AI calculation force drive liquid cooling becomes standard. In 2026, the liquid-cooled server industry will enter the fast lane of large-scale landing. The investment scale of China's data center liquid-cooled market will reach 76.55 billion billion yuan, with an annual compound growth rate of 21%, of which cold plate liquid-cooled accounts for more than 70% of the market. The cold plate type liquid cooling uses deionized water or glycol solution as the circulating cooling medium. By installing a cold plate above the server chip, the cooling liquid flows through the cold plate to take away heat.
New requirements for flow meters for liquid cooling systems. The liquid cooling system consists of CDU (cooling distribution unit), coolant distribution pipeline, quick connector, manifold, sensor and other core components. The water inlet and outlet of each cabinet need to install flow meters to monitor whether the coolant distribution is balanced. Micro-small caliber electromagnetic flowmeter is mainly used for cabinet level and CDU secondary side, facing four major technical challenges:
- Extremely compact installation space: The internal space of the cabinet is narrow, and the volume of the flowmeter directly affects the cooling circuit integration scheme.
- Very low coolant conductivity: Deionized water is only about 5 μS/cm, ethylene glycol solution is lower, and some scenes are even lower than 2 μS/cm
- 7 × 24 hours continuous operationLong-term stability is crucial
- Secure Communications Requirements: Some high-security data centers prohibit wireless communication and require Bluetooth to be turned off immediately after the equipment leaves the factory.
In addition, liquid cooling systems usually require flow meters to provide multi-parameter integration (flow, temperature, conductivity) required for cold calculation, and to access the DCIM dynamic ring monitoring system with standard IO-Link or 4-20mA signals.

2. M6300Y core technology advantages
M6300Y micro-caliber electromagnetic flowmeter is a customized model of Herbalife Water based on MicroFLOW M6300 series platform and specially optimized for the special needs of liquid cooling industry.
1. Ultra-compact structure design, adapt to the small space of the cabinet
The M6300Y adopts a compact integrated structure, the converter is highly integrated with the sensor, and the length and volume of the whole machine are controlled in an extremely simplified range. The PCB size is only 63 × 43 × 23mm, and the probe diameter is only 2mm, which can be directly embedded in compact spaces such as CDU or cabinet. Even in cabinets with dense piping, it can be easily installed in series without additional changes to the original piping design.
2. Low conductivity measurement capability, suitable for liquid cooling medium
Equipped with broadband dual-frequency excitation and AI intelligent algorithm, the lower limit of conductivity measurement is as low3 μS/cm. Even in the face of deionized water (about 5 μS/cm) or lower conductivity of ethylene glycol solution, it can ensure stable and accurate measurement. This capability enables the M6300Y to have significant technical advantages in liquid cooling scenarios-ordinary electromagnetic flowmeters have weak signals and data jumps in low conductivity media, while the M6300Y can stably output continuous and reliable flow data.
3. Wide range ratio and high precision, covering the whole flow range
M6300Y flow rate range covers 0.001-10 m/s, range ratio up1000:1 or more. Precision optionalClass 0.2, Class 0.3, Class 0.5The repeatability is better than 1/3 of the accuracy value. It supports stable measurement of flow velocity as low as 0.05 m/s, and accurately captures small flow changes under low load conditions of liquid cooling system.
4. Multi-material selection, suitable for different cooling media
The M6300Y offers full custom flexibility on the wetted material:
- Lining material: Provide PEEK (temperature resistance 260 ℃), ceramic (temperature resistance 400 ℃), PTFE three options. PEEK and ceramic linings are particularly popular in the liquid cooling industry because of their strong chemical resistance and difficulty in absorbing media, making them particularly suitable for cooling media such as glycol solutions.
- Electrode material: Optional Hastelloy HC, 316L, tantalum, etc., covering the full scene requirements from conventional coolant to special chemical media.
- Shell material: Standard 304 stainless steel, 316L can be upgraded according to requirements.
5. Multi-parameter integration and intelligent communication.
M6300Y支持流量、温度、电导率多参数同步测量,为冷量计算提供完整数据支撑。输出接口支持4-20mA、脉冲、RS485 Modbus等多种信号,可对接DCIM动环监控系统。通过定制通信协议,可满足高安全数据中心对无线通信的禁用要求。
三、液冷场景典型应用
应用点位 | Media Characteristics | Recommended Configuration | 核心价值 |
Cabinet-level cooling circuit | 去离子水/乙二醇溶液,低电导率 | DN6-DN15,PEEK衬里,4-20mA输出 | 监测单机柜冷却液流量,保障GPU稳定运行 |
CDU二次侧 | 冷却液,流量波动小 | DN15-DN25,陶瓷衬里,RS485通讯 | 监控冷却分配单元循环流量,优化冷量分配 |
储能设备液冷管路 | 乙二醇溶液,温度变化大 | DN10-DN20,PEEK lining, multi-parameter integration | Real-time monitoring of coolant circulation flow to ensure stable operation of temperature control system |
Core Points of 4. Selection
Step 1: Confirm the caliber and flow range
The liquid-cooled cabinet-level piping is usually DN6-DN15, and the secondary side of the CDU is DN15-DN25. M6300Y covers a full range of DN3-DN32 micro-caliber, the core principle of selection isThe commonly used flow falls within the range of 30% ~ 80% of the instrument range.。
Step 2: Confirm conductivity adaptation
The conductivity of deionized water is about 5 μS/cm, and that of ethylene glycol solution is lower. M6300Y Low conductivity limit3 μS/cmIt can stably measure most liquid cooling media.
Step 3: Confirm material selection
- Conventional coolant (deionized water/glycol solution) PEEK lining 316L electrode, both cost and corrosion resistance
- High temperature or special chemical cooling mediumCeramic lining Hastelloy electrode, better temperature resistance and corrosion resistance
Step 4: Confirm communication and integration
M6300Y支持4-20mA、脉冲、RS485 ModbusA variety of output modes, such as seamless docking DCIM dynamic ring monitoring system. High security data center optionalNo Bluetooth version, Turn off wireless communication when leaving the factory.
5. FAQ (Frequently Asked Questions)
Q1: What is the difference between M6300Y and ordinary M6300 series?
A:M6300Y is a customized model of Herbalife Water based on M6300 series platform and specially optimized for the special needs of liquid cooling industry. The core differences are: more compact PCB size (63 × 43 × 23mm), lower conductivity measurement limit (3 μS/cm), and multi-parameter integration and communication protocol adaptation optimized for liquid cooling scenarios.
Q2: Can M6300Y measure ethylene glycol solution?
A: Sure. The lower limit of M6300Y conductivity is as low as 3 μS/cm, which can stably measure low conductivity liquid cooling media such as deionized water and ethylene glycol solution. PEEK lining is recommended, which has strong chemical corrosion resistance and is not easy to absorb media.
Q3: What is the installation space requirement of M6300Y?
A:M6300Y adopts ultra-compact design, PCB size is only 63 × 43 × 23mm, probe diameter is only 2mm. Even in cabinets with densely packed piping, it can be easily installed in series without requiring any modifications to the existing piping layout.
Q4:M6300Y how to access the data center monitoring system?
A: It supports 4-20mA, pulse, RS485 Modbus and other output modes, and can seamlessly interface with DCIM dynamic ring monitoring system. For high-security data centers, a Bluetooth-free version is optional, and wireless communication is turned off at the factory.
Q5: How long is the maintenance cycle of M6300Y?
A: All welded steel structure, no moving parts, no pressure loss. With the relatively clean medium environment of the liquid cooling system, it can run stably for a long time. Calibration checks are recommended every 12 months.
Quick Look-up Table for 6. Selection Decision
Your needs | Recommended Configuration | Core Advantages |
Cabinet-level cooling circuit flow monitoring | DN6-DN15,PEEK衬里,4-20mA输出 | Ultra-compact size, low conductivity adaptation, real-time monitoring |
CDU Secondary Circulating Flow Monitor | DN15-DN25,陶瓷衬里,RS485通讯 | Wide range ratio, multi-parameter integration, moving ring docking |
储能设备液冷管路 | DN10-DN20,PEEK lining, multi-parameter integration | Temperature resistance 260 ℃, flow/temperature synchronous measurement |
High security data center | No Bluetooth version, custom communication protocol | Secure Communications, Compliance Deployment |
This article is based on Herbalife Water's public technical data and 2026 market data. Please combine the specific liquid cooling system working conditions (pipe diameter, cooling medium, conductivity, installation space, etc.) for selection. It is recommended to contact the manufacturer to provide technical solutions and on-site survey services.
If you would like to learn more about flow meters orFlowmeter Selection,You can consult HerbalifeFlowmeter manufacturersTechnical Support: 13926998050 (same number on WeChat) for assistance.
- Buy flowmeter, first look at the site conditions! 2026 Depth Comparison of Domestic and Imported Brands of Electromagnetic Flowmeter Manufacturers
- 2026 domestic electromagnetic flow manufacturers recommended: top ten brands of intelligent flow meter recommended reasons
- How to choose imported flat electromagnetic flowmeter? How to choose micro-caliber, conventional flange and plug-in electromagnetic? Recommended by domestic high-quality manufacturers
- Four major brands of electromagnetic flowmeter hard core PK: Herbalife Water, Cloud Meter, E H, Cologne, who is more worthy of choice?
- November 2026 Top Ten Brands of Electromagnetic Flowmeter at Home and Abroad Ranking
- Recommended Top Ten Brands of Electromagnetic Flowmeter in 2026: Reference for Project Selection of Water Treatment, Sewage and Conductive Liquid
- TOP5 Manufacturer's Selection Guide for Food Sanitary Electromagnetic Flowmeter: Material and Connection Mode Check before Purchase
- Cost-effective chemical oxygen demand water quality online monitor manufacturers contact information
- How to choose the integrated electromagnetic water meter? Domestic high-quality manufacturers recommendation and selection guide
- Selection of Electromagnetic Flowmeter for Small Diameter Ultra-high Temperature Medium Metering Engineering