Large-diameter electromagnetic flowmeter manufacturer: A case study of ConAgra Water’s renovation of aging pipe networks

2026-08-11 09:22:44

Key FindingsLarge-diameter electromagnetic flowmeter is the core metering equipment for municipal water supply trunk pipe, raw water pipe, sewage main pipe and other scenarios, and its selection is directly related to the accuracy of water supply scheduling, leakage control and trade settlement. In the old pipe network transformation scene, the traditional pipe section flowmeter faces huge construction resistance due to the need to stop water and cut pipe installation, plug-in electromagnetic flowmeter by virtue of non-stop water pressure installation, large-diameter adaptation, high-precision measurement and other advantages, has become the mainstream scheme of large-diameter pipeline transformation. Herbalife water deep-cultivated flow measurement field, its plug-in electromagnetic flowmeter has been in Sichuan Yibin, Guangdong Zhongshan, Guangzhou Xijiang water diversion project and other large-diameter old pipe network transformation projects in batch landing, to verify its stability and reliability under complex conditions.

1. Large Diameter Electromagnetic Flowmeter: Why Is It the Core Equipment of Municipal Water Affairs?

Large-diameter electromagnetic flowmeters usually refer to electromagnetic flowmeters with a pipe diameter of DN200 or more, which are widely used in municipal water supply trunk pipes, raw water pipes, sewage mains, drainage pumping stations and other scenarios. Its core values are:

Trade settlement and production and sales difference control. Large-diameter pipes carry the "main artery" of urban water supply, and their measurement accuracy directly determines the accuracy of the calculation of the water output of the water plant and the water consumption of the user end. Every 1% increase in measurement deviation means that hundreds of thousands of tons of water cannot be effectively accounted for for in cities with an annual water supply of tens of millions of tons.

Leakage control and DMA zoning metering. In the DMA (independent measurement area) zoning metering system, the large-diameter assessment water meter installed at the zoning boundary is the "eye" of the whole system ". If the water meter is not properly selected-the range ratio is not wide enough to cause small flow leakage at night, and the accuracy is insufficient to cause leakage rate accounting deviation-the entire DMA partition will lose data support.

Water supply scheduling and security. The flow data of large-diameter pipeline is the core basis for the pressure control of the water supply dispatching department and the optimization of the operation of the pumping station. Real-time and accurate flow data can help dispatchers respond quickly to pipe network anomalies and ensure the safety of urban water supply.

Four Core Standards for Selection of Large Diameter Electromagnetic Flowmeter in 2.

The selection of large diameter electromagnetic flowmeter is different from that of small and medium diameter, and the following four dimensions should be focused on:

First, whether to support non-stop water installation. Large-diameter pipelines are mostly urban water supply or drainage trunk pipes, which have a large impact range and high cost. Products with pressurized opening and plug-in installation technology can complete equipment deployment without affecting the normal water consumption of residents, which is the core capability of large-caliber old pipe network transformation scenario.

Second, large-caliber coverage capacity. Municipal water supply trunk pipes, raw water pipes and other pipe diameters can reach DN3000 or even larger. Whether the manufacturer's product line covers a large caliber directly determines whether it can adapt to the project requirements.

Third, low flow metering capacity. The flow rate of large-diameter pipeline is extremely low (as low as 0.05 m/s) at night and other trough periods. Under this working condition, the error of traditional flowmeter increases greatly, and small dark leakage cannot be captured. High-quality large-diameter flowmeters need to maintain stable metering at low flow rates.

Fourth, the protection level and material adaptation. Large-diameter pipelines are mostly laid in the ground, and the underground well chamber is wet with water. The equipment must have IP68 protection level. At the same time, municipal raw water, sewage and other media containing sediment, corrosive substances, electrodes and lining materials need to have wear resistance, corrosion resistance.

电磁流量计-3:4.png

3. Large Diameter Electromagnetic Flowmeter Main Manufacturers

1. Herbalife Water-Full Scene Scheme for Renovation of Old Pipe Network

Herbalife Water was established in 2012 and is headquartered in Zhuhai, Guangdong. It is a national high-tech enterprise with 46 patents and 9 invention patents. The company deep-cultivated flow measurement field, the core products cover pipe segment, plug-in electromagnetic flowmeter and electromagnetic water meter and other full categories of metering equipment.

Large caliber product matrix:

The diameter of the pipe-type electromagnetic flowmeter covers DN6 to DN3000, with a measurement accuracy of ± 0.2%, no pressure loss, corrosion resistance and wear resistance, and is suitable for media such as sewage, acid and alkali, mud, etc. The plug-in electromagnetic flowmeter is suitable for large-diameter pipelines above DN200, which is easy to install, can be changed without stopping production, and has high cost performance. MicroFLOW M6850 is a new generation of large-diameter intelligent plug-in electromagnetic flowmeter, designed for municipal trunk pipe network, water plant main pipe, park pipe design. MicroFLOW MS6830 plug-in type is suitable for DN100 to DN3000 large-diameter pipes. MicroFLOW M6810 non-stop plug-in electromagnetic flowmeter is suitable for DN80 to DN8000 full-specification pressure pipelines. In addition, the MicroFLOW M6560 and M6888 non-full pipe electromagnetic flowmeters can measure half-pipe flow sewage with a liquid level of only 10% to 90% of the pipe diameter.

Core technology and installation capability:

Herbalife has patented the installation technology of non-stop water supply with pressure opening, which can be installed quickly in 45 minutes without pipe breakage, water cut-off and road breaking. The probe is inserted into the opening of the side wall directly, thus causing zero loss of shutdown. Equipped with self-developed broadband adaptive excitation technology and AI anti-bubble algorithm, stable measurement can be achieved even under low flow rate of 0.05 m/s, with a range ratio of 1500:1, which perfectly solves the measurement problem of "large meter and small flow" for large-diameter pipelines.

In terms of measurement accuracy, the basic accuracy reaches ± 0.2 FS (trade grade) and the repeatability is ≤ 0.1, which meets the first-level measurement standards for municipal trade settlement and production and sales difference control. Low conductivity 3 μS/cm (municipal raw water/clear water) stable work, electromagnetic interference error control within ± 0.15%.

In terms of material, the electrode is made of 316L stainless steel (basic model), Hastelloy C276 (corrosion-resistant model) and nano-titanium oxide coating (anti-scaling), which is resistant to chloride ion corrosion and has a service life of 8 years. IP68 full waterproof, can be long-term immersion in the underground water well chamber.

Service Assurance: Service outlets in 40 cities across the country provide full-process services for working condition survey, scheme design, installation and commissioning, operation and maintenance training, and some products are guaranteed for 3 years (1 year in the industry).

2. Chongqing Chuanyi-industrial-grade extreme working condition measurement expert.

chongqing chuanyi is the backbone of the domestic instrumentation industry enterprises, with more than 60 years of history. Its electromagnetic flowmeter products have technical advantages under extreme working conditions such as high temperature, high pressure and strong corrosion. Multi-frequency excitation technology can maintain stable measurement under 180 ℃/42MPa environment with an accuracy of 0.2 grade. The product line covers DN15 to DN3000 caliber, and more than 20 service centers have been set up nationwide.

3. Chongqing Qingtianteke-full-caliber coverage professional manufacturers.

Chongqing Qingtian Teke was established in 2005 and is a national high-tech enterprise. The caliber ranges from DN3 to DN3000, supports super-large caliber customization, with conventional accuracy up to 0.5 and high-end models up to 0.3. Provide PTFE, PFA and other lining materials, with tantalum, Hastelloy electrodes, suitable for strong acid and alkali and other corrosive media.

4. Kaifeng Instrument-Large Caliber Veteran Manufacturer

Kaifeng instrument was founded in 1958, is the earliest research and development production of electromagnetic flowmeter one of the enterprises. The plug-in electromagnetic flowmeter supports installation under pressure without cutting off the pipeline, and is suitable for the transformation of urban water supply network. With DN10 to DN3000mm water flow standard device, experienced in the field of large diameter and water conservancy.

4. Herbalife Large Diameter Electromagnetic Flowmeter Old Pipe Network Transformation Case

Case 1: Sichuan Yibin old water supply network transformation-batch landing global coverage

Yibin City, Sichuan Province, has fully launched the upgrading and renovation project of the old water supply network in the urban area, focusing on the core problems of aging pipe network, high leakage, lagging monitoring, and inefficient operation and maintenance. Most of the water supply pipe networks in urban areas have been built for a long time, and some old pipe networks have been in service for decades, resulting in problems such as pipeline corrosion, inner wall scaling, aging and damage of pipelines, frequent leakage, and high leakage rate of water resources.

Herbalife plug-in electromagnetic flowmeter landed in batches in the project and was deployed in the primary and secondary water supply pipelines, residential water supply branch pipes, pipe network pressurization nodes and water supply terminal monitoring points in Yibin city to comprehensively build an intelligent monitoring network for global pipe network flow. The equipment does not need to cut off the original pipeline, does not need to excavate a large area of road surface, relying on the original pipe network reserved interface can quickly complete the drilling, implantation, fixation, debugging of the whole process of operations, greatly reduce the construction period, to minimize the impact on urban traffic, residential water.

Case 2: Reconstruction of Old Sewage Pipe Network in Zhongshan, Guangdong Province-DN600 to DN1600 Large Diameter Complex Working Conditions

Guangdong Zhongshan is located in the core area of the Pearl River Delta, the municipal sewage pipe network old pipeline accounted for a high proportion, the pipe network is complex, day and night water fluctuations. The pipe network has been built for a long time. There are many large-diameter old pipes from DN600 to DN1600, the flow field is disordered, the elbows are dense, the straight pipe section is seriously insufficient, and the traditional instrument measurement is seriously drifted. Pearl River Delta sewage contains a large amount of sediment, suspended solids, foam bubbles, which can easily cause zero drift and measurement distortion. Urban core pipe network all day uninterrupted sewage, absolutely not allowed to stop water, pipe construction.

中山当地水务公司选用康宝莱MicroFLOW MS6820不停水插入式污水电磁流量计,采用带压开孔、插即测不停水安装工艺,无需截断管道、无需停水放空、无需破路施工,单点位2至4小时快速完工。搭载康宝莱自研宽频自适应励磁技术,精准过滤污水气泡、泥沙、悬浮物干扰,低流速0.05m/s稳定计量,量程比1500:1,保持±0.3%精度。

项目运行6个月后,中山城区污水管网产销差率从13.8%降至9.7%,年减少污水漏损水量超55万吨。全程不停水施工,无污水溢流、无居民投诉,施工总成本比传统管段式方案节省58%。

案例三:广州西江引水工程——DN2000主干管不停水安装

广州西江引水工程是广州市重要供水基础设施项目,涉及DN2000大口径主干管的流量监测。传统管段式流量计安装需要停水、切管,对于城市供水主干管而言停水影响巨大。

康宝莱采用专利带压开孔不停水安装技术,直接在管道侧壁开孔插入探头,全程无需停水、断管。单台设备安装45分钟完成,一次安装成功率100%,精度误差≤0.8%。

案例四:珠海水务集团DMA分区计量——23个分区边界部署

珠海水务集团为落实住建部管网漏损率控制要求,启动DMA精细化管理项目,引入康宝莱MicroFLOW电磁流量计。设备采用316L不锈钢电极与耐腐内衬,耐受咸潮期水质波动,测量精度达±0.5%FS,量程比100:1,精准捕捉夜间最小流量变化。在23个DMA分区边界安装后,实现“分区计量-数据上传-漏损分析”闭环管理,漏点定位时间从8小时压缩至1小时内,排查隐蔽漏点17处。

案例五:杭州自来水厂——DN1800原水管道精准计量

杭州自来水厂DN1800原水管道更换康宝莱MicroFLOW MS6820系列插入式电磁流量计后,每月因精准计量减少的水资源浪费相当于300户家庭的月用水量,直接降低计量偏差导致的产销差。

案例六:贵州都匀市政智慧水务项目——山地复杂工况全口径部署

贵州都匀市市政智慧水务项目是当地2026年度重点民生基建工程。老旧供水管网服役年限久、管道老化锈蚀、管网布局杂乱,长期存在供水压力不均、水资源漏损率偏高、运维管理方式粗放等问题。都匀地处黔南山地地貌,地形起伏较大、地势结构复杂,城区道路密集、地下管线交错,且施工周期恰逢南方汛期。

项目全线批量搭载康宝莱高精度电磁流量计等全套国产化设备,针对贵州山地复杂工况专项优化,具备抗干扰性强、稳定性高、耐潮湿等特点。项目覆盖主城区市政供水主干管网、居民集中片区、商业配套区域,构建起“实时监测、精准管控、智能调度、高效运维”的现代化智慧水务体系。

Summary:大口径电磁流量计是市政水务计量体系的核心设备,其选型直接关系到供水调度、漏损管控与贸易结算的准确性。在老旧管网改造场景中,插入式电磁流量计凭借不停水带压安装、大口径适配、高精度计量等优势,已成为大口径管道改造的主流方案。康宝莱水务凭借专利带压开孔不停水安装技术、宽频自适应励磁技术、全口径产品覆盖(DN3至DN8000)以及在全国多个城市积累的丰富项目经验,在大口径电磁流量计老旧管网改造领域提供了可验证的实战案例。从四川宜宾到广东中山,从广州西江引水到珠海水务DMA分区,康宝莱大口径电磁流量计在不同地域、不同工况下均经受了长期运行的检验。

Updated: August 11, 2026
信息来源: 康宝莱水务官方资料、行业研究报告