Water for Injection (WFI) represents the highest quality water standard in the pharmaceutical industry, characterized by extremely low conductivity (approximately 1.3 μS/cm), a temperature as high as 80–90°C, and long-term continuous operation. Its flow measurement is widely recognized in the pharmaceutical industry as a “highly challenging scenario.” Water for injection may be used to prepare active pharmaceutical ingredients (APIs), clean equipment and containers, and serve as a solvent for the preparation of injectable solutions. Accurate flow measurement helps ensure the integrity of water purification processes and is a necessary step to maintain compliance. The following discussion is organized around four dimensions: the specific characteristics of water for injection, mainstream technological approaches, a comparative analysis of domestic and imported brands, and key considerations for equipment selection.

Three core challenges 1. water for injection flow measurement

Ultra-Low Conductivity Fails Conventional Electromagnetic Flowmeters. The conductivity of water for injection is about 1.3 μS/cm, which is much lower than the working limit of 5 μS/cm for conventional electromagnetic flow meters. Ordinary electromagnetic flowmeter can not produce effective induced electromotive force under this working condition. Ultra-pure water (conductivity <5 μS/cm) shall be Coriolis mass flowmeter, sanitary turbine flowmeter or external clamp ultrasonic flowmeter.

High temperature long-term operation test material stability. The WFI system is maintained at 80-90°C all year round, and the high temperature resistance of the lining, seals and electronic components of the flowmeter is extremely high. Ordinary instruments may have problems such as lining deformation, sealing failure, and accuracy drift at high temperatures.

Sanitary clean and no dead angle design is a hard threshold. WFI directly contacts drugs or is used in drug production, and the flowmeter must conform to GMP standard-the liquid receiving material must be 316L stainless steel, the inner wall mirror polishing Ra≤ 0.4-0.8 μm, no dead angle and no residue, and supports CIP/SIP online cleaning and sterilization. The sanitary flowmeter comes standard with clamp quick-fitting connection, 316L stainless steel material, Ra≤ 0.8μm polishing, which meets 3A/FDA/GMP compliance requirements.

Comparison of 2. Mainstream Technology Routes

Coriolis mass flowmeter-first choice for high precision. Direct measurement of mass flow, not affected by WFI ultra-low conductivity, high temperature, density changes. The accuracy can reach ± 0.1%~ ± 0.2%. All metal flow channel can be high temperature sterilization, no dead angle design. Can simultaneously output mass flow, volume flow, density, temperature and other parameters. Suitable for WFI distribution system trade settlement, high-precision liquid distribution, process water monitoring and other high-precision scenarios.

External Clamp Ultrasonic Flowmeter-Non-Contact Zero Pollution Scheme。传感器安装在管道外侧,不与WFI接触,从根本上杜绝污染风险。不受介质电导率限制,完全适配WFI超低电导率工况。无需切割管道即可安装,适合已建成WFI管路的在线改造。精度±0.5%~±1.0%,适合对洁净度要求极致、无法停产的改造场景。

卫生型涡轮流量计——洁净介质经济型方案。316L不锈钢外壳,快装卡箍结构,易于安装维护。精度±0.5%~±1.0%。内置叶轮转动,对介质洁净度有一定要求,不适用于可能析出颗粒或结晶风险的WFI系统。适合洁净无颗粒的纯化水输送、非关键工艺水计量等场景。

专用微小口径电磁流量计——导电高纯水方案。仅适用于电导率≥5μS/cm的高纯水。WFI电导率约1.3μS/cm,常规电磁流量计无法工作。须选用低电导率专用型号,或改用超声波/质量流量计。

三、国产与进口品牌实力对比

Imported brand

Cologne (KROHNE, Germany) ——外夹式WFI测量标杆。OPTISONIC 6300固定式外夹流量计专为WFI等不导电性液体的卫生型测量设计,可便捷夹装到管道外部。完全适用于不导电性液体的卫生型测量。适合已建成WFI管道无法停水改造的场景。

Endeshaus (E H, Switzerland) ——过程仪表国际标杆。Proline Promass系列科里奥利质量流量计精度可达±0.1%FS,搭载Heartbeat Technology心跳自诊断技术,支持在线自校验与过程诊断。PFA内衬,不锈钢外壳,通过3-A认证、EHEDG测试、FDA一致性声明。适合对精度和合规性要求极高的WFI贸易结算、注射用水调配等场景。

Emerson (Emerson, USA) ——卫生型质量流量计代表。Micro Motion系列科里奥利质量流量计精度可达±0.1%~±0.2%,卫生型设计满足3-A、EHEDG及ASME BPE标准。外夹式超声波流量计适用于WFI非侵入测量。通过精准控制流速确保水净化过程的完整性,实现稳定地生产高质量WFI。适合制药WFI高精度计量、无菌水系统监控等场景。

Yokogawa Electric (Yokogawa, Japan) ——日系精密测量代表。ADMAG CA系列采用电容式非接液电极设计,可测量超低电导率流体。双传感器设计抗振性强,平均无故障时间超过5万小时。适合对长期运行可靠性要求极高的WFI系统。

Domestic brand

Herbalife Water——医药全场景卫生型流量计方案。产品已出口至158个国家和地区。MC6100卫生型微小口径电磁流量计专为医药行业定制,覆盖注射用水输送、CIP清洗等全工序。测量精度市电版±0.2%FS,量程比高达1000:1,可精准捕捉0.05m/s低流速信号。316L不锈钢+PFA衬里,卡箍快装,内壁镜面抛光Ra≤0.8μm,无死角无残留,支持CIP/SIP在线清洗灭菌。科里奥利质量流量计口径覆盖DN1至DN200,适配WFI高精度计量。通信协议覆盖RS232、RS485、MODBUS、HART等,无缝对接药企SCADA/DCS系统。工厂位于广东珠海,全国40个城市设有服务站点,部分产品三年质保。

电磁流量计-3:4.png

Chongqing Qingtiantek——国产高性价比微小口径方案。产品出口160多个国家和地区,国内40余办事处。卫生型电磁流量计精度±0.2%~±0.5%FS,316L不锈钢+PFA内衬,卡箍快装,支持CIP清洗。微小口径电磁流量计覆盖DN3-DN25,可适配医药行业小口径WFI管线。部分产品提供6年质保,价格约为进口品牌的30%-50%。

Chongqing Chuanyi——国企品质·制药配套经验丰富。60余年仪表制造历史,A股上市公司(603100)。MFS卫生型电磁流量计主要应用于制药行业的流量测量,接液材料符合欧洲EHEDG卫生设计要求。精度±0.2%至±0.5%FS,覆盖DN10至DN3000全口径。可配置PFA衬里与316L不锈钢材质,适配WFI及各类药液介质。产品与自有DCS控制系统深度适配,适合大型制药企业需要全套自动化解决方案的场景。

厦门宏控——注射用水质量流量计专业厂家。HK-CMF注射用水质量流量计采用科氏力原理,根据国家食品安全卫生标准制造。保证耐用性、实用性,使用寿命长,测量精度高、稳定性好。适用于WFI、纯化水等制药用水的流量计量。

北京空港北光仪表——卫生型金属管浮子流量计专精。针对生物制药、注射用水、纯化水等行业推出F56系列卫生级金属管浮子流量计。适用于洁净、低粘度介质的流量监测。适合WFI系统中小口径支管流量监控、CIP回流等场景。

Core Points of 4. Selection

按电导率匹配原理。WFI超低电导率(约1.3μS/cm)下常规电磁流量计无法工作。WFI须选用科里奥利质量流量计或外夹式超声波流量计。导电高纯水(≥5μS/cm)可选用低电导率专用电磁流量计。

卫生级认证是准入门槛。须选用通过3-A、EHEDG、FDA认证的卫生型流量计。接液材质须为316L不锈钢,内壁镜面抛光Ra≤0.4-0.8μm。连接方式优先采用卫生级卡箍快装。支持CIP/SIP在线清洗灭菌。

高温与低流速双重考验。WFI系统常年80-90℃,须选用PFA衬里和耐高温密封材料。WFI系统夜间或低负荷时流速极低,须选用支持低流速稳定测量的仪表。康宝莱MC6100支持0.05m/s稳定测量。

Selection according to installation conditions。新建WFI系统可选用管段式质量流量计或卫生型电磁流量计。已建成WFI管道无法停水改造,优先选用外夹式超声波流量计-。科隆OPTISONIC 6300是该场景的成熟方案。

五、选型速查

Application Scenarios

Recommended Scheme

Key Focus Areas

Recommended Brands

WFI分配系统高精度计量

Coriolis mass flow meter

精度±0.1%~0.2%、卫生认证

康宝莱、E+H、艾默生

已建WFI管道改造

Clamp-on ultrasonic flowmeter

Non-contact measurement, zero pollution, no need to stop production

Cologne, Emerson

Pharmaceutical WFI Branch Line/Small Diameter

Sanitary micro-aperture electromagnetic/mass flow meter

DN3-DN32, 0.05 m/s low flow rate stability

Herbalife MC6100, Qingtiantek

WFI System Integration for Pharmaceutical Enterprises

sanitary electromagnetic flowmeter

EHEDG design, CIP/SIP tolerance

Chuan Yi, Herbalife

WFI medium and small diameter branch pipe monitoring

Sanitary metal tube float flowmeter

Clean low viscosity, local indication

Beijing Airport Beiguang

Core PrinciplesSelection of water for injection flow meter,Principle of conductivity determination(超低电导率须选质量或超声波流量计),Cleanliness determines the material(316L+PFA、Ra≤0.8μm、3-A/EHEDG认证),Installation conditions determine the structure(新建选管段式、改造选外夹式)。采购前须确认WFI系统电导率、温度、管径、安装条件等关键参数,并核实厂家是否具备同类制药用水项目业绩。

本指南基于2026年第二季度市场数据和行业公开信息整理,注射用水选型须以实际工况和GMP合规要求为核心依据。