NB-IoT系列物联网水表是我公司采用最新物联网通信技术研发的高科技机电一体智能化远传水表。以先进的微电脑控制为核心,采用窄带射频收发技术与新型低功耗设计、内置了高性能电机阀,配合使用高灵敏磁感应部件构成的智能化物联管理水表。NB-IoT系列物联网水表集预付费、自动计量、状态报警及平台灵活设置相关参数及功能于一体的高智能产品。
Consult Now
NB-IoT远传物联网阀控水表MicroFLOW产品简介
 

企业资质.png

 
NB-IoT远传物联网阀控水表MicroFLOW技术参数

Product Features

Precise measurement: Equipped with a high-quality movement, it delivers accurate measurements with minimal error. The magnetosensitive sensor, which employs an electromechanical separation scheme, is unaffected by water quality and exhibits strong anti-interference capability.

Dual-digit display: The digital display on the meter body and the mechanical dial wheels show readings simultaneously, ensuring data accuracy, reliability, and intuitiveness. It features forward/reverse counting correction: forward counts are added, reverse counts are subtracted, ensuring electromechanical synchronization.

超低功耗:本产品待机电流17uA,配3.6V  8500mAh锂电池,每天上传一次数据可使用6年以上。

Superior waterproofing: The circuitry features multi-layered waterproofing to ensure excellent water resistance.

LCD Display: Features a large-size LCD screen that displays valve status, signal strength, cumulative flow, and other information across eight screens.

NB-IoT: The water meter features a built-in NB module and SIM card, utilizing NB‑IoT wireless communication with CoAP peer-to-peer messaging. Data transmission is handled via interactions with telecom operators’ base stations, eliminating the need for additional intermediate data collection devices. Water consumption and water meter status are reported regularly or in real time, with an automatic meter reading success rate of over 99%.

Touch buttons: Equipped with low-power touch buttons that display different content upon touch and facilitate inspection and maintenance; users can operate them at any time without needing any tools.

Periodic Self-Reporting: The meter periodically reports data; by default, it proactively sends a data record to the smart water management system every 24 hours (with an adjustable interval ranging from 1 to 120 hours).

Battery level alert: Sends a warning to the platform when the battery capacity drops below a specified threshold; can also send an alarm to the platform if a lithium battery loses power.

Strong magnetic attack alarm: When subjected to a strong magnetic attack, the device can send an alert to the platform, indicating that the water meter’s battery should be replaced promptly with one of the specified model and specifications.

Remote control function (valve‑controlled meter): Based on reported data such as strong magnetic attack events, abnormal meter status, and user arrears, the smart water management system makes a comprehensive assessment and can remotely shut off the valve.

Flexible configuration: Configure the power-off valve‑closing function (by default, it only reports events without closing the valve); the smart water‑management system flexibly configures control functions at the meter end. Both can be configured with a power-failure valve-shutoff function, realizing the true smart-meter attribute.

Technical Specifications

(1) Water meter temperature class: T50;

(2) Operating water pressure: 0.03MPa ~ 1.6 MPa; Maximum allowable pressure: 1.6 MPa;

(3) Pressure loss: ∆p≤ 0.063MPa;

(4) Protection rating: IP68;

(5) Electromagnetic environment class: E1/E2;

(6) Climatic and mechanical environmental conditions: Class B/Class O;

(7) Electromechanical conversion error: ≤±0.01 m³;

(8) Battery service life: Under normal conditions, it can exceed 6 years.

(9) Maximum permissible error for Class 2 meter:

When the flow in the low area is Q1 ≤ Q

When the high-range flow Q2 ≤ Q

(Where Q1 is the minimum flow rate and Q2 is the transition flow rate.)

Maximum permissible error for Class 1 meter:

When the low-range flow rate Q1 ≤ Q

When the high-range flow Q2 ≤ Q

(Where Q1 is the minimum flow rate and Q2 is the transition flow rate.)

(10) Ambient temperature: -20℃ to 50℃.

Installation Requirements

(1) Before the installation of the water meter, the pipeline should be washed to remove the stones, sediment and other debris in the pipeline to prevent the water meter from being blocked or damaged (Note: If the water contains impurities, a filter should be installed).

(2) The installation position of the water meter should be able to avoid exposure to the sun, and heat preservation measures should be taken in the cold winter season. The installation environment of water meter shall be anti-freezing, anti-pollution, anti-flooding, anti-magnetic and anti-mechanical damage, and easy to observe the display screen, reading, disassembly and maintenance.

(3) Pay attention to the installation reservation size must conform to the installation requirements of the external dimension of the water meter (see Table 3). It is recommended to select the expansion joint with the corresponding caliber downstream of the water meter. The tensile force of the water meter shell is damaged due to insufficient reservation size, and the responsibility is borne by you.

(4) When the water meter is installed, the direction of the arrow on the case must be consistent with the direction of water flow, and the installation must be horizontal. The pipes connected to both ends of the water meter shall be installed on the same axis to prevent the water meter from being subjected to excessive stress caused by the pipes and fittings. If necessary, the water meter shall be mounted on a base or bracket. The upstream and downstream water pipes shall be properly fixed so that no part will be displaced by the thrust of the water when the water meter is removed or one side connection is disconnected.

(5) Pay attention to the connection length of the water meter. When the pipeline spacing at both ends exceeds the connection length of the water meter, the pipeline spacing should be corrected to meet the connection length of the water meter. Otherwise, forced installation with too large spacing will cause the threaded end of the water meter connection to break or the pipe joint to break and the connection nut to damage. In addition, the upstream and downstream pipes of the water pipe must be fastened to ensure that when the water meter is disassembled or removed on one side, the parts will not move.

(6) The water meter should not be directly connected with the pipeline. The water meter and the pipeline should be connected through the connecting pipe, sealing washer and connecting nut. When disassembling, do not pull hard to avoid twisting the case.

(7) In order to ensure accurate measurement, direct connection between the water inlet valve and the water meter should be avoided during installation. A filter and a rectifying straight pipe section with a diameter greater than 10 times of the water meter must be installed between the water meter and the valve. A rectifying straight pipe section with a diameter greater than 5 times the diameter of the water meter shall be installed downstream of the water meter, and a check valve shall be installed if necessary. It is recommended that the water outlet is more than 0.5m above the water meter.

(8) When installing a water meter at the water inlet end of the boiler, a check valve must be installed to prevent hot water and steam from returning to damage the water meter.

(9) It is forbidden to put any articles above the control part of the water meter. Pay attention to moisture-proof and moisture-proof, and it is strictly forbidden for water droplets to penetrate into the water meter controller to damage the control system and affect the normal use of users.

(10) Due to the influence of water pressure fluctuation and water hammer in the pipeline, it can be observed that the water meter pointer jumps up and down when water is not used, and the water meter pointer rotates slightly, which is not a water meter failure.

(11) In all cases, especially when installing a meter in a meter well, the meter should be installed at a sufficient height from the ground (the bottom surface of the meter well), and the meter well should be protected from flooding to avoid pollution.

(12) Due to the failure to strictly follow the installation precautions, the water meter or its accessories are damaged, and all losses shall be borne by the installer.

使用要求

(1)初次使用时,水应缓慢进入主管道,并打开放气口,勿使残存空气促使水表超速运转导致损坏。

(2)水表使用过程中,必须保证进、出水阀门完全打开;禁止因用水量较小而将阀门处于半开状;并采取措施防止不利的水利条件(空化、浪涌、水锤)损坏水表。

(3)无必需时,不要轻易触摸按键或长时间按压,以延长电池使用寿命。不要将强磁、高热等物品靠近表具,以免影响计量精度或控制盒受热损坏。

(4)长期使用后,基表和阀门由于杂物堵塞或者零件磨损等原因引起的误差或者开关阀门不灵活,需检修后使用,发现不正常现象应通知自来水公司或物业检修。

Installation matters
 
1、NB-IoT远传物联网阀控水表MicroFLOWInstallation should be away from elbows, obstacles, variable diameter, valves, in order to ensure a stable flow field, while requiring a longer upper limit of straight pipe, straight pipe length greater than 10D, straight pipe section longer than 5D.

2. Site environment installationNB-IoT远传物联网阀控水表MicroFLOWWhen the requirements of straight pipe section cannot be met, rectifiers can be connected in series to greatly reduce the requirements for straight pipe section.

3, ifNB-IoT远传物联网阀控水表MicroFLOWWhen installed outdoors, the instrument sunshade shall be added to avoid sun and rain.

4、NB-IoT远传物联网阀控水表MicroFLOWIt is prohibited to install in strong vibration occasions and environments containing a large amount of corrosive gases.

5、NB-IoT远传物联网阀控水表MicroFLOWDuring installation, do not share the power supply with equipment that pollutes the power supply, such as frequency converter and electric welding machine. If necessary, install purified power supply for the instrument.

6、NB-IoT远传物联网阀控水表MicroFLOWBefore pre-installation, please reconfirm the connection mode of the pipe section and prepare related items such as gaskets and bolts for flange connection. Production must be stopped before installation and the relevant regulations of the factory must be strictly observed.
Recommended Products
电磁水表6500E

Electromagnetic water meter 6500E

Intelligent metering is based on the permanent magnet to generate a stable working magnetic field, with 0.3 seconds of high-frequency sampling, accurate metering, intelligent learning of water rules, automatic...
Consult Now
Learn more
MicroFLOW M6300微小口径电磁流量计

MicroFLOW M6300 micro-small diameter electromagnetic flowmeter

Wide measuring range: 0.001~10 m/s minimum measurable flow rate: 3 L/H accuracy: 0.3 or 0.5 medium...
Consult Now
Learn more
MicroFLOW M6300电磁流量计

MicroFLOW M6300 electromagnetic flowmeter

The electromagnetic flowmeter uses the principle of Faraday's law of phenol water induction, that is, when a conductive object moves in a magnetic field to cut a magnetic wire, a sense is generated in the conductor...
Consult Now
Learn more
MicroFLOW MS6830 不停水插入式污水电磁流量计

MicroFLOW MS6830 non-stop plug-in sewage electromagnetic flowmeter

This product is a highly reliable, integrated insertion electromagnetic flowmeter designed for the flow measurement of conductive liquids such as municipal sewage and industrial wastewater....
Consult Now
Learn more
Submit your requirements to receive a quote.
Welcome to fill in the following form, improve your product requirements, contact phone number, demand equipment, we will contact you within 24 hours for further communication and confirmation.
After-sales service
Support "Three Guarantees Service", can phone door-to-door quickly for you to solve problems!
Customized design
Customized according to drawings and customized to meet customer requirements
Quality inspection
The quality inspection department performs quality inspection at various levels, and leaves the factory after one-to-one calibration.
24/7 support
24 hours online service, 72 hours technical engineers to arrive on-site service