MicroFLOW M6300 electromagnetic flowmeter
An electromagnetic flowmeter operates on the principle of Faraday’s law of electromagnetic induction, which states that when a conductive object moves through a magnetic field in such a way as to cut magnetic field lines, an electromotive force is induced in the conductor. The induced electromotive force E is: E = KBdV. The flow rate Q is: Q = 3600 × V × S, where: K – meter coefficient; B – magnetic flux density (T); d – electrode spacing (m); V – average fluid velocity (m/s); S – cross-sectional area of the conduit (m²). When measuring flow, a conductive liquid flows at velocity V through a magnetic field perpendicular to the direction of flow.