MicroFLOW M6380 split electromagnetic flowmeter
Based on Faraday’s law of electromagnetic induction, a pair of detection electrodes is mounted on the pipe wall perpendicular to both the pipe axis and the magnetic field lines. When a conductive liquid flows along the pipe axis, it cuts across the magnetic field lines, inducing a voltage. This induced voltage is detected by the two electrodes, and its magnitude is directly proportional to the flow rate, given by the equation: E = KBVD, where: E is the induced voltage; K is a coefficient related to the magnetic field distribution and axial length; B is the magnetic flux density; V is the average velocity of the conductive liquid; and D is the electrode spacing (the inner diameter of the measuring tube).
Consult Now