Product Overview: The thermal mass flow meter is a flow instrument designed based on the principle of thermal diffusion. That is, when a fluid flows past a heated object, the amount of heat lost by the object is proportionally related to the fluid flow rate. The sensor of this series of flow meters includes two standard-grade RTDs, one of which is used for
Consult Now
Flange thermal gas mass flowmeter product introduction
 

image.png

 
Technical Parameters of Flange Thermal Gas Mass Flow Meter

Product Overview

Thermal mass flow meters are flow instruments designed based on the principle of thermal diffusion. That is to say, the heat loss of the heating object when the fluid flows through the heating object is proportional to the flow rate of the fluid. The sensors of this series of flow meters have two standard RTD's, one is used as the heat source and the other is used to measure the fluid temperature. When the fluid flows, the temperature difference between the two is linearly related to the flow rate, and then this relationship is converted into linear output of the measured flow rate signal through microelectronic control technology.

Product Advantages

1. Easy installation, simple maintenance, two-way detection, anti-vibration;

2. Flow measurement up to 24 points;

3, the correction of the output analog multi-point nonlinear curve correction;

4. Wide range ratio 100:1;

5. Simultaneous detection of flow and temperature, switching display;

6, large diameter small flow measurement, can do leak detection;

7, the use of proprietary technology "double balance structure" package sensor;

8. Proprietary high humidity and high temperature algorithm, the medium temperature can reach 500 ℃;

9. Direct mass flow measurement, without the need for temperature and pressure compensation;

Technical Specifications

Application areas

★Oxygen, nitrogen, hydrogen, chlorine, aeration, gas and other multi-component gas measurement

★Measurement of blast furnace gas and coke oven gas

★Biogas, aeration and chlorine measurement in water treatment

★Compressed air measurement

★Measurement of gas flow rates for natural gas, liquefied petroleum gas, flare gas, and other gases

★Measurement of Primary and Secondary Air Flow of Blast Furnace in Power Plant

★Flow measurement of underground ventilation or exhaust system

★Air flow measurement in gas process

★Measurement of Piping Gas Flow in a Calcination Furnace

★Measurement of gas flow in the production process of cement and glass plant

★Gas Flow Measurement in Solvent Recovery Systems

★Gas flow measurement in semiconductor chip fabrication process

★Measurement of carbon dioxide gas flow in beer production process

★Gas flow (velocity) measurement in heating ventilation and air conditioning systems

 

Installation matters
 
1、Flange-mounted thermal gas mass flow meterInstallation should be away from elbows, obstacles, variable diameter, valves, in order to ensure a stable flow field, while requiring a longer upper limit of straight pipe, straight pipe length greater than 10D, straight pipe section longer than 5D.

2. Site environment installationFlange-mounted thermal gas mass flow meterWhen the requirements of straight pipe section cannot be met, rectifiers can be connected in series to greatly reduce the requirements for straight pipe section.

3, ifFlange-mounted thermal gas mass flow meterWhen installed outdoors, the instrument sunshade shall be added to avoid sun and rain.

4、Flange-mounted thermal gas mass flow meterIt is prohibited to install in strong vibration occasions and environments containing a large amount of corrosive gases.

5、Flange-mounted thermal gas mass flow meterDuring installation, do not share the power supply with equipment that pollutes the power supply, such as frequency converter and electric welding machine. If necessary, install purified power supply for the instrument.

6、Flange-mounted thermal gas mass flow meterBefore pre-installation, please reconfirm the connection mode of the pipe section and prepare related items such as gaskets and bolts for flange connection. Production must be stopped before installation and the relevant regulations of the factory must be strictly observed.
Recommended Products
电磁水表6500E

Electromagnetic water meter 6500E

Intelligent metering is based on the permanent magnet to generate a stable working magnetic field, with 0.3 seconds of high-frequency sampling, accurate metering, intelligent learning of water rules, automatic...
Consult Now
Learn more
MicroFLOW M6300微小口径电磁流量计

MicroFLOW M6300 micro-small diameter electromagnetic flowmeter

Wide measuring range: 0.001~10 m/s minimum measurable flow rate: 3 L/H accuracy: 0.3 or 0.5 medium...
Consult Now
Learn more
MicroFLOW M6300电磁流量计

MicroFLOW M6300 electromagnetic flowmeter

The electromagnetic flowmeter uses the principle of Faraday's law of phenol water induction, that is, when a conductive object moves in a magnetic field to cut a magnetic wire, a sense is generated in the conductor...
Consult Now
Learn more
MicroFLOW MS6830 不停水插入式污水电磁流量计

MicroFLOW MS6830 non-stop plug-in sewage electromagnetic flowmeter

This product is a highly reliable, integrated insertion electromagnetic flowmeter designed for the flow measurement of conductive liquids such as municipal sewage and industrial wastewater....
Consult Now
Learn more
Submit your requirements to receive a quote.
Welcome to fill in the following form, improve your product requirements, contact phone number, demand equipment, we will contact you within 24 hours for further communication and confirmation.
After-sales service
Support "Three Guarantees Service", can phone door-to-door quickly for you to solve problems!
Customized design
Customized according to drawings and customized to meet customer requirements
Quality inspection
The quality inspection department performs quality inspection at various levels, and leaves the factory after one-to-one calibration.
24/7 support
24 hours online service, 72 hours technical engineers to arrive on-site service
Consultation Hotline
Contact via WeChat
Get Quote
Back to top