Product Features 1, 0.5% Linearity, 0.2% Repeatability; 2. Non-conductive/special medium measurement; 3. Low voltage multi-pulse balanced transmission and reception; 4. Positive/negative/net accumulator; 5. Isolated RS-485 interface, supporting MODBUSRTU;
Consult Now
Four channel ultrasonic flowmeter product introduction
 

image.png

 
Technical parameters of four channel ultrasonic flowmeter

Product Features

1.0.5% linearity, 0.2% repeatability;

2. Non-conductive/special medium measurement;

3. Low voltage multi-pulse balanced transmitting and receiving;

4. Positive/negative/net accumulator;

5. Isolated RS-485 interface, support MODBUS RTU;

6. Anti-interference design, electrically isolated DC power supply;

7. Built-in heat measurement/calorimeter;

8.2-way two-wire PT1000 platinum resistance input circuit;

9.1 analog 4-20mA output, OCT frequency signal output;

10. Optional DC/AC/220 AC power supply;

11, the number of sampling times per cycle increased to 128, 22 picosecond time difference measurement resolution;

How to use

(1) Introduction to the window

The main groups of the window are: flow display, sensor settings, communication settings, output settings, clear flow, 4 ~ 20mA calibration, etc. The subgroups are described below:

1. Flow display: used to display the window, showing instantaneous flow, positive cumulative flow, negative cumulative flow, net cumulative flow, instantaneous flow rate, date and time, current output, etc.

2. Sensor settings: set the sensor type, pipe diameter, pipe wall thickness, fluid type, probe type, probe installation method and other parameters, display the installation distance.

3. Communication settings: Set RS485 communication baud rate, modbus RTU communication address, etc.

4. Output settings: used to set the instantaneous flow corresponding to 4 ~ 20mA, OCT pulse output correlation

5. Clear flow: used to clear cumulative flow, historical flow records, etc. Clear cumulative flow meter requires a password. Please contact the manufacturer for the password.

6.4 ~ 20mA Calibration: Used to calibrate 4 ~ 20mA output calibration. 

(2) Quickly input pipeline parameters and steps:

1. M50, sensor type (the host supports a variety of probes), sensors mainly include plug-in type, surface-mounted type or specific sensors whose parameters have been written into the equipment; If the sensor is an integrated pipe section of pipe section and the parameters are not written into the equipment, such as DN100 and DN200, the sensor type is plug-in type; Except for the integrated pipe section with special parameters written.

2. M56管道内径

3. M57 pipe wall thickness: M50 is selected as surface-mounted type with this item

4. M58 pipe material: M50 is selected as surface-mounted type with this item

5. M64 fluid type: water by default

6. Installation method of M51 probe: Z, V, N, W,M50 is selected as surface mount type

7. M137固化参数(此操作非常重要)

8. M9501设置为传感器设置

9.M518显示Q(信号质量),T(时间传输比);一般情况下要求Q(信号质量)大于50%,时间传输比T在100±3%以内;M543查看信号质量,要求信号质量大于40%

10. M514显示第一声道的瞬时流量。

11. M9501设置为流量显示界面

如果设备为双声道流量计,则还需要查看第二声道传感器数据,查询与设置方法与第10、11步相同,但是窗口则变为M618、M614、M543。 

(3)、判断流量计工作是否正常

> M518: 如果Q>80 97%50,则仪表第一声道正常工作

> M618: 如果Q>80 97%50,则仪表第二声道正常工作

注意事项

1、观察安装现场管道是否满足直管段前10D后5D以及离泵30D的距离。(D为管道内直径)

2、确认管道内流体介质以及是否满管。

3、确认管道材质以及壁厚(充分考虑到管道内壁结垢厚度)

4、确认管道使用年限,在使用10左右的管道,即使是碳钢材质,建议也采用插入式安装。

5、前四步骤完成后可确认使用何种传感器安装

6、开始向表体输入参数以确定安装距离。

7、非常重要:精确测量出安装距离。

Technical Specifications

 

项目性能,参数
测 量 主 机精 度1.0 %
重 复 性0.2%
流速范围0.1 ~ ±7 m/s。
Measurement principle of ultrasonic propagation time difference principle, 32-bit CPU work, 8-byte double floating-point operation.
测量周期50mS. (每秒20次,每个周期采集64组数据)。
显    示2×10或者4*8背光型汉字液晶显示器,低功耗为段码液晶显示。
操   作4×4轻触键盘/4按键输入。
输   入2路二线制PT1000铂电阻输入回路,可实现热量计量功能
输    出电流信号:4~20mA, 阻抗0~500W,浮空,精度0.1%FS。脉冲信号:正、负、净流量及热量累计脉冲OCT输出。数据接口:标准隔离RS-485接口。
Other functions Memory day, month, year cumulative flow. Fault self-diagnosis function; network working mode, etc.
Medium-sized sensor standard M1 type, suitable for pipe diameter DN50 ~ DN700mm
Plug-in type: the material of the measuring pipe is not limited (weldable or non-weldable) and is suitable for pipe diameter above DN80.
Standard pipe section type: suitable for pipe diameter DN10-DN400, the measurement accuracy of the whole machine is 0.5%.
The length of the cable can be extended to 100m (please contact the manufacturer if it exceeds this length).
Pipe lining steel, stainless steel, cast iron, hard plastic, cement pipe and all other dense pipe, allowed to have lining.
Inner diameter 50mm -300mm.
The length of straight pipe section shall be ≥ 10D upstream, ≥ 5D downstream and ≥ 30D away from the pump outlet.
Fluid types: water, sea water, acid and alkali, food oil, steam, coal, diesel, crude oil, alcohol, beer and other uniform liquids that can spread ultrasonic waves.
The turbidity is ≤ 10000 ppm, and the bubble content is small.
Temperature -10~150 ℃.
The flow direction can be measured separately for the forward and reverse flow, and the net flow can be measured.
工作环境温   度主机:-10-70℃ (大于此温度范围要求请与厂家联系)探头:-30℃ ~ +150℃
Humidity host: 85% RH probe: can be immersed in water, water depth ≤ 3 meters.
Power JHA type ordinary version: DC24V ,AC220V power supply mode. JHA low-power version: 3.6v lithium battery/5~9V (or 9~36V).

Installation matters
 
1、four-channel ultrasonic flowmeterInstallation should be away from elbows, obstacles, variable diameter, valves, in order to ensure a stable flow field, while requiring a longer upper limit of straight pipe, straight pipe length greater than 10D, straight pipe section longer than 5D.

2. Site environment installationfour-channel ultrasonic flowmeterWhen the requirements of straight pipe section cannot be met, rectifiers can be connected in series to greatly reduce the requirements for straight pipe section.

3, iffour-channel ultrasonic flowmeterWhen installed outdoors, the instrument sunshade shall be added to avoid sun and rain.

4、four-channel ultrasonic flowmeterIt is prohibited to install in strong vibration occasions and environments containing a large amount of corrosive gases.

5、four-channel ultrasonic flowmeterDuring installation, do not share the power supply with equipment that pollutes the power supply, such as frequency converter and electric welding machine. If necessary, install purified power supply for the instrument.

6、four-channel ultrasonic flowmeterBefore pre-installation, please reconfirm the connection mode of the pipe section and prepare related items such as gaskets and bolts for flange connection. Production must be stopped before installation and the relevant regulations of the factory must be strictly observed.
Recommended Products
电磁水表6500E

Electromagnetic water meter 6500E

Intelligent metering is based on the permanent magnet to generate a stable working magnetic field, with 0.3 seconds of high-frequency sampling, accurate metering, intelligent learning of water rules, automatic...
Consult Now
Learn more
MicroFLOW M6300微小口径电磁流量计

MicroFLOW M6300 micro-small diameter electromagnetic flowmeter

Wide measuring range: 0.001~10 m/s minimum measurable flow rate: 3 L/H accuracy: 0.3 or 0.5 medium...
Consult Now
Learn more
MicroFLOW M6300电磁流量计

MicroFLOW M6300 electromagnetic flowmeter

The electromagnetic flowmeter uses the principle of Faraday's law of phenol water induction, that is, when a conductive object moves in a magnetic field to cut a magnetic wire, a sense is generated in the conductor...
Consult Now
Learn more
MicroFLOW MS6830 不停水插入式污水电磁流量计

MicroFLOW MS6830 non-stop plug-in sewage electromagnetic flowmeter

This product is a highly reliable, integrated insertion electromagnetic flowmeter designed for the flow measurement of conductive liquids such as municipal sewage and industrial wastewater....
Consult Now
Learn more
Submit your requirements to receive a quote.
Welcome to fill in the following form, improve your product requirements, contact phone number, demand equipment, we will contact you within 24 hours for further communication and confirmation.
After-sales service
Support "Three Guarantees Service", can phone door-to-door quickly for you to solve problems!
Customized design
Customized according to drawings and customized to meet customer requirements
Quality inspection
The quality inspection department performs quality inspection at various levels, and leaves the factory after one-to-one calibration.
24/7 support
24 hours online service, 72 hours technical engineers to arrive on-site service
Consultation Hotline
Contact via WeChat
Get Quote
Back to top