Product Features
The portable ultrasonic flowmeter is easy to install, which can reduce installation time and cost. No head loss, no moving parts, maintenance and replacement is very convenient. Support BTU function, can be used as portable BTU (energy) meter. Compared with other types of flow meters, portable ultrasonic flow meters are easy to move and easy to carry in different places.
Working principle
Ultrasonic flowmeter is a device that measures the information of fluid flow velocity by detecting the effect of fluid flow on ultrasonic beam. According to the detection method of signal, it can be divided into propagation velocity difference method, Doppler method, beam shift method, noise method and related method. The Doppler method utilizes the acoustic Doppler principle, determining fluid flow rate by measuring the Doppler frequency shift of ultrasonic waves scattered by particles in a non-uniform fluid. It is suitable for measuring the flow rate of fluids containing suspended particles, bubbles, and similar constituents. The beam‑shift method measures fluid velocity by detecting the change in the propagation direction of an ultrasonic beam as it travels through the fluid, which varies with the flow speed. However, at low flow rates, its sensitivity is very low, limiting its practical applicability. At present, the most widely used measurement principle is the “time-difference method.” By integrating multi-pulse technology, digital signal processing, and signal-processing circuitry, measurement data are displayed in real time.
The “time-difference method” works by having a transmitting sensor generate an ultrasonic signal that propagates through the airflow; the signal travels via the pipe wall and the fluid to the receiving sensor. Simultaneously, the receiving sensor emits an identical ultrasonic signal, which travels back through the pipe wall and the fluid to the transmitting sensor. At this point, the flow velocity causes a time difference; the flow velocity can be calculated from this time difference, and the flow rate can then be determined.
Technical Specifications


Product Installation
Try to install the flow indoor meter; if you must install it outdoors, you should take measures to avoid direct sunlight or rain.
The flow meter should be installed away from the high temperature, heat radiation or corrosive gas of the equipment.
Ultrasonic flow cannot be installed near motors, transformers or other power sources. Instruments are likely to cause electromagnetic interference. Do not install ultrasonic flow meters near the inverter or do not connect with the inverter distribution cabinet to avoid interference.
To facilitate installation and maintenance, leave sufficient space around the flow meter.
Flow support instrument
Avoid installing flow measurements on pipes with mechanical vibrations. If you have to install it there, D ○ take shock absorption measures. You can install a hose for the transition, or set a support point on the 2DN pipeline with an absorption pad meter upstream and downstream of the fluid. Try not to install flow metering on longer overhead pipes, because the sagging of the pipe will cause leakage between flow meters and flanges. If you must do this, you must set up point meters at 2DN on the pipeline upstream and downstream of the support fluid.
Requirements for liquid receiving materials
Ultrasonic flow meter can measure the liquid flow of a single medium; the same medium can be divided into three specifications: low temperature, high temperature, and ultra-high temperature), and different flow meters are applied to different temperatures.
Hazardous Conditions
You can choose process instrumentation with explosion-proof enclosure and intrinsically safe
The explosion-proof flow meter has an intrinsically safe design circuit to ensure its safety and
Flame retardant operation. Each first-class instrument shall have a nameplate clearly identifying its
Authentication. Be sure to install and use process instruments according to the explosion-proof level and the protection level shown on the nameplate.
In order to ensure the measurement accuracy of the flowmeter, try to meet the following conditions
Requirements for length of straight pipe installed near the flow meter:
Upstream> 20D, downstream> 10D.