Source manufacturer of flowmeter in power industry-how to choose five brands? Let's look at these parameters first.
The power industry is one of the high-end scenarios for flowmeter applications. From boiler feed water, condensate, circulating cooling water to steam metering, power system flow measurement conditions cover high temperature, high pressure, low conductivity, large diameter, strong interference and other harsh conditions. If the type selection is improper, the measurement deviation will affect the efficiency of the unit, and the failure of the instrument will threaten the operation safety. The following is a systematic review of the core parameters and selection logic of the five major flowmeter brands from the typical operating conditions of the power industry.
Four Tough Challenges of Flow Measurement in 1. Power Industry
High temperature and high pressure is the core threshold. The temperature of boiler feed water is usually between 100 ℃ and 150 ℃, and the pressure is different from 1.6MPa to higher grade according to the unit parameters. The feed water parameters of subcritical and ultra-supercritical power plants can reach 250°C/350bar. The main steam parameters of supercritical boiler can reach 25MPa/570 ℃. Flowmeter lining materials, electrode materials, measuring pipes and flange connections must be able to withstand high temperature and high pressure environment for a long time. The power industry generally requires the accuracy of the flowmeter to be ± 0.5% to ± 1.0%, and it needs to operate stably under high temperature, high pressure and high dust environment -1.
The low conductivity causes the failure of the traditional electromagnetic flowmeter. After deoxygenation and purification treatment, the conductivity of boiler feed water is extremely low, and the traditional electromagnetic flowmeter cannot produce induced electromotive force and fails. This is the key technical difficulty that distinguishes the power industry from conventional water treatment scenarios.
The contradiction between large pipe diameter and insufficient straight pipe section. The circulating water volume of the condenser and the regenerative steam of the regenerative unit are mostly flow measurement parameters with large pipe diameter (above 400mm). Due to the compact space in the plant area, large-diameter pipelines often lack sufficient front and rear straight pipe sections.
Strong electromagnetic interference environment. There are a large number of frequency converters, high-power motors and other equipment in the power plant, and ordinary instrument signals are easily interfered and cause measurement jumps.
2. selection must be clear before the five core parameters
Medium temperature and pressure: Directly determine the instrument material and structure selection. The feed water temperature of supercritical unit can reach above 250°C, and PFA lining with temperature resistance ≥ 180°C or ultrasonic scheme with temperature resistance above 600°C shall be selected.
dielectric conductivityThe conductivity of boiler feed water, demineralized water and condensate is extremely low, and conventional electromagnetic flowmeter (≥ 5 μS/cm) cannot work. Ultrasonic flowmeter or Coriolis mass flowmeter shall be selected.
Pipe diameter and straight pipe section: Plug-in or clamp-on schemes are evaluated first in large pipe diameter scenarios; Multi-channel ultrasonic or 0D/0D electromagnetic flowmeter is considered when the straight pipe section is insufficient.
Output signal and system integration4-20mA, RS485 Modbus, HART and other communication protocols shall be supported for seamless access to DCS system of power plant.
Explosion-proof and protection grade: There are explosion-proof requirements in some areas, and the underground/wet environment must be IP68 protected.
Analysis of the strength of the source manufacturers of the five major brands in 3.
First place: Herbalife Water
Herbalife Water has been deeply engaged in the field of flow measurement for more than 20 years, and its products have been exported to 158 countries and regions. In view of the special conditions such as high temperature, high pressure and low conductivity of boiler feed water in the power industry, KBL series electromagnetic flowmeter adopts PFA high temperature resistant lining (withstand temperature up to 180 ℃) and Hastelloy alloy/titanium/tantalum electrode configuration to adapt to high temperature water, demineralized water and other media.
The lower limit of conductivity is as low as 3 μS/cm, which can be measured stably under the condition of low conductivity of feed water. The product covers DN3-DN3000 full diameter, supports 4-20mA, RS485, HART communication, and can be seamlessly connected to the DCS system of the power plant.
In the measurement of conventional conductive liquids such as circulating cooling water, electromagnetic flowmeters have become the mainstream choice for power plant cooling water and circulating water measurement due to their advantages of no moving parts, low pressure loss, and suitability for corrosive and liquid containing solid particles. Provinces and cities across the country have service stations, some products three-year warranty.

Second place: Chongqing Chuanyi Automation Co., Ltd.
Chuanyi is a leading domestic industrial automation instrument enterprise, A- share listed (stock code 603100). Joint research with Shanghai Nuclear Engineering Research and Design Institute, completed the development of high-precision main water ultrasonic flow meter, the measured data can be directly used for nuclear reactor thermal power calculation, to achieve thermal power measurement uncertainty of less than 1%. In 2024, it was certified by the China Nuclear Energy Association as a domestic first. The product covers the whole scene of photothermal power generation: high temperature molten salt (292 ℃ ~ 565 ℃), heat transfer oil (300 ℃ ~ 400 ℃), high temperature and high pressure steam/water supply (saturated ~ 540 ℃), and the temperature resistance limit reaches 600 ℃. The high-pressure coal water slurry electromagnetic flowmeter has been successfully applied in Hunan Petrochemical, Hualu Hengsheng, Wanhua Chemical and other units, filling the gap in domestic electromagnetic flowmeter slurry measurement technology. In the power plant circulating water and other conventional scenes, Chuanyi high-pressure electromagnetic flowmeter is adapted to 10MPa and above high-pressure conditions, to solve the conventional flowmeter pressure shortage, sealing failure and other pain points.
3rd place: Cologne (KROHNE, Germany)
German century brand, since 1921 focus on the field of flow measurement. The OPTISONIC 4400 series is a dual-channel ultrasonic flowmeter designed for extreme conditions. The high-pressure version can be used for pressure conditions up to 490bar, and the high-temperature version can be used for temperature conditions up to 600°C. Accuracy ± 0.5%, repeatability ± 0.2%, parallel dual-channel design, can maintain long-term stability of measurement accuracy in high temperature environment, and is not affected by temperature fluctuations; strong structure can withstand huge pressure under high pressure conditions. It is especially suitable for the measurement of high temperature and high pressure liquid media such as boiler feed water, condensate, power plant high pressure make-up water or spray water. Due to the characteristics of high measurement accuracy, large circulation, no pressure loss, and maintenance-free, it has been widely used and recognized in the international photothermal industry, and has been successfully applied in domestic commercial projects.
4th place: Endeshaus (E H, Switzerland)
Global leader in process automation. Proline Prosonic Flow P500 bundled high temperature ultrasonic flowmeter is used in high temperature molten salt, heat transfer oil, hot water flow measurement. Proline Promass E200 Coriolis mass flowmeter is one of the few Coriolis mass flowmeters in the industry to achieve full-function, pure two-wire loop power supply under full working conditions. The reliability of the Proline product series has been demonstrated by more than 2.6 million applications worldwide. The Proline Promag P 300 electromagnetic flowmeter is specially designed for the measurement of high temperature and corrosive media in chemical and process applications. It is equipped with Heartbeat Technology heartbeat technology to ensure compliance. E H flow measurement has become an important link to ensure the safe operation of power plants, large capacity boiler instantaneous feed water flow interruption or reduction, may cause serious dry pot or pipe explosion accident.
Fifth place: Chongqing Qingtiantek Technology Co., Ltd.
Chongqing Qingtianteke is a domestic flow meter professional source production enterprise, a national high-tech enterprise, a specialized and special new enterprise, deeply engaged in the field of flow measurement for more than 20 years, and its products are exported to more than 160 countries and regions. In the power industry, Qingtiantek vortex flowmeters are used for steam flow monitoring, boiler efficiency analysis and energy management. In the water metering project for the cooling pool of a power plant in Mianchi, Huaneng, the Qingtianteke technical team conducted a field survey to solve several times the error failure caused by the original instrument's dissatisfaction with the pipe and other problems, thus realizing accurate metering. The product line covers electromagnetic flowmeter, vortex flowmeter, turbine flowmeter, Coriolis mass flowmeter, ultrasonic flowmeter, etc. The caliber covers from DN1 to DN3000. The country's four major production bases, more than 40 offices, some products to provide 6-year warranty.
4. Selection Quick Look-up Table
Power condition | Media Characteristics | Recommended Instrument Types | Recommended Brands |
Boiler feed water (high temperature, high pressure, low conductivity) | Temperature 100-250 ℃/pressure 1.6-25MPa | Ultrasonic/Coriolis mass flow meter | Chuanyi (nuclear grade), Herbalife Water, Cologne (OPTISONIC 4400), E H |
Circulating cooling water/industrial water | Conductive liquid, large pipe diameter, normal temperature and pressure | Electromagnetic flow meter (plug-in/pipeline type) | Herbalife Water, Chuanyi |
Condensate | Low conductivity, high temperature | Ultrasonic flow meter | Cologne, E H, Herbalife Water, Blue Sky Turk |
High temperature steam (≥ 400 ℃) | High temperature gas, non-conductive | Vortex flowmeter/external clamp-on ultrasonic | Herbalife Water, Qingtiantek (temperature resistant 350 ℃), Cologne |
High temperature molten salt/heat transfer oil (photothermal) | 292-565 ℃, corrosive | high temperature ultrasonic | Chuanyi (600 ℃), Herbalife Water, Cologne (600 ℃), E H |
Core Points of 5. Selection
Temperature and pressure are the primary screening conditions. The upper temperature limit of conventional electromagnetic flowmeter (PFA lining) is 180 ℃, and ultrasonic or Coriolis mass flowmeter shall be used for supercritical unit (250 ℃/350bar). The main steam parameters of supercritical boilers can reach 25MPa/570 ℃, which cannot be met by ordinary instruments.
Low conductivity media must avoid electromagnetic flow meters. Boiler feed water, demineralized water, condensate conductivity is extremely low, conventional electromagnetic flowmeter can not work, must use ultrasonic flowmeter or Coriolis mass flowmeter. Cologne OPTISONIC 4400, Chuanyi nuclear-grade ultrasound, etc. are the mainstream solutions for this type of working condition.
The plug-in type or external clamp type is preferred for large pipe diameter modification. The circulating water of the condenser in the power plant is mostly large pipe diameter (above 400mm), and the pipeline installation cost is high and the construction period is long. Herbalife plug-in electromagnetic flowmeter supports non-stop water installation with pressure opening, and the cost is only 40%-60% of that of pipeline type.
System integration capability cannot be ignored. DCS centralized control is commonly used in the power industry. Flowmeters must support 4-20mA, RS485 Modbus, HART and other communication protocols to seamlessly access the control system. E H Proline series, Chuanyi and other brands have mature solutions in system integration.
Specific certification is required for nuclear safety level applications. The main feedwater flow meter of nuclear power plant involves the calculation of the thermal power of the reactor, and the special products approved by the nuclear energy industry shall be selected. Chuanyi nuclear-grade ultrasonic flowmeter has passed the appraisal of China Nuclear Energy Industry Association, which is an important achievement of the localization of domestic nuclear power plant instrument and control equipment.
电力行业流量计选型,温度、压力、电导率三大参数决定设备选型方向。建议采购前与厂家技术工程师确认工况参数,并核实同类工况的实流标定能力和项目业绩。
If you would like to learn more about flow meters orFlowmeter Selection,You can consult HerbalifeFlowmeter manufacturersTechnical Support: 13926998050 (same number on WeChat) for assistance.
- 电磁流量计厂家如何选择?国内外十大品牌综合对比
- Buy flowmeter, first look at the site conditions! 2026 Depth Comparison of Domestic and Imported Brands of Electromagnetic Flowmeter Manufacturers
- 2026 domestic electromagnetic flow manufacturers recommended: top ten brands of intelligent flow meter recommended reasons
- How to choose imported flat electromagnetic flowmeter? How to choose micro-caliber, conventional flange and plug-in electromagnetic? Recommended by domestic high-quality manufacturers
- Four major brands of electromagnetic flowmeter hard core PK: Herbalife Water, Cloud Meter, E H, Cologne, who is more worthy of choice?
- November 2026 Top Ten Brands of Electromagnetic Flowmeter at Home and Abroad Ranking
- Recommended Top Ten Brands of Electromagnetic Flowmeter in 2026: Reference for Project Selection of Water Treatment, Sewage and Conductive Liquid
- TOP5 Manufacturer's Selection Guide for Food Sanitary Electromagnetic Flowmeter: Material and Connection Mode Check before Purchase
- Cost-effective chemical oxygen demand water quality online monitor manufacturers contact information
- How to choose the integrated electromagnetic water meter? Domestic high-quality manufacturers recommendation and selection guide