-
2026-10-16DMA zoning metering scheme: how to choose electromagnetic water meter? Multi-product line covers complex working conditions
1. DMA分区计量: The core approach to smart water management—water supply network leakage—is a common challenge plaguing the global water industry. In China, the leakage rate in urban public water supply networks has long remained between 12% and 15%, with some older urban areas experiencing rates exceeding 20%. The 2026 policy requires that the leakage rate in public water supply networks of prefecture-level and above cities be kept below 9%, and some pilot demonstration zones have already moved toward a 7% target. The core logic of DMA分区计量 is that a DMA (District Metered Area, independent metering area) is internationally recognized as the most effective method for detecting pipeline network leakage. -
2026-10-16Municipal pipe network renovation project: how to choose plug-in electromagnetic flowmeter? Guangdong Herbalife Water Solution
The measurement problem of 1. municipal pipe network transformation The municipal pipe network is the "aorta" of urban water supply, carrying the task of water transportation from the water plant to thousands of households. As China's urbanization process enters the middle and late stages, a large number of water supply pipe networks built in the early stage have been in operation for more than 20 years, facing problems such as pipeline aging, serious leakage and lack of measurement. The transformation of municipal pipe network has become a rigid demand in the water industry. The core metering problem of municipal pipe network transformation cannot be installed without water supply: municipal pipe network undertakes the task of water supply in most areas of the city, and an hour of water supply may affect tens of thousands or even hundreds of thousands of residents. Traditional pipe section flowmeter needs to be cut -
2026-10-16How to choose a sewage flow meter manufacturer? Municipal discharge sewage, industrial and chemical sewage measurement and selection guidance
1. sewage flowmeter selection: Why can't we just look at the price? Sewage flowmeter is the core measurement equipment for sewage treatment plants, municipal pipe networks, industrial wastewater discharge, environmental monitoring and other scenarios. Its measurement accuracy directly affects the regulation of sewage treatment process, environmental protection emission data compliance, sewage charge accounting, pipe network leakage analysis and other aspects. According to industry data, about 41% of the domestic environmental protection monitoring substandard and sewage fines are related to inaccurate flowmeter measurement, insufficient anti-clogging performance, poor corrosion resistance and data distortion. Therefore, the choice of a suitable sewage characteristics of the flow meter, can not only look at the price, but from the media characteristics, -
2026-10-16Water quality monitoring project: how to choose the conductivity meter? 2026 water quality analyzer purchase guide and source manufacturers recommended
1. conductivity meter: the core instrument of water quality monitoring conductivity is the core index to measure the conductivity of water body, which directly reflects the concentration of soluble electrolyte in water. In waterworks, conductivity is used to monitor the pollution degree of raw water and the purity of factory water. In the preparation of industrial pure water, conductivity is the key basis for judging whether the effluent from reverse osmosis membrane meets the standard. In sewage treatment, changes in conductivity can indirectly reflect the fluctuation of influent water quality. In chemical, pharmaceutical, electric power, food and beverage industries, conductivity is a key parameter for process control and product quality. Conductivity meters are therefore the most frequently used data in water quality monitoring systems. -
2026-10-15Sugar industry project: how to choose the brand of high viscosity flowmeter? High viscosity fluid working condition configuration selection guide, attached to the source manufacturer
The difficulty in selecting flowmeters for sugar industry projects lies not in the flow measurement itself, but in the fact that the viscosity of sugar solution varies greatly with temperature and concentration. The sugar liquid itself is a finished or semi-finished raw material, and the measurement deviation directly affects the proportion of ingredients and batch settlement. The error of ordinary water flowmeter only affects the reading. Once the sugar liquid ingredients are measured incorrectly, the sugar content of the finished product will be unqualified and the whole batch will be reworked. The working conditions of sugar industry media vary greatly and cannot be generalized: molasses is a high-viscosity medium at normal temperature and corrosive; Syrup has high temperature and large viscosity fluctuation in the process of concentration; White granulated sugar dissolved liquid phase is clean but the concentration changes obviously. Three types of working conditions have different requirements for instrument selection. domestic -
2026-10-15Liquid cooling project: how to choose the brand of coolant flowmeter? Small pipe diameter, low conductivity, no straight pipe section working condition configuration guide, attached to the source manufacturer
The difficulty of flowmeter selection for liquid cooling projects lies not in the flow measurement itself, but in the special physical properties and pipeline conditions of the coolant. The coolant is not ordinary tap water, and the measurement deviation directly affects the evaluation of heat dissipation efficiency and the judgment of equipment operation. The error of the water supply flowmeter only affects the reading; once the flow of the liquid cooling system is inaccurate, it may lead to misjudgment of the heat dissipation margin, equipment frequency reduction or even shutdown. The working conditions of liquid cooling medium and pipeline are very different and cannot be generalized: the liquid cooling of server cold plate is mostly small diameter and low conductivity coolant; The energy storage liquid cooling pipeline is compact and the installation space is limited. The CDU pipeline in the data center has pump pulsation and uneven flow distribution. Three types of work -
2026-10-15How to choose the plug-in electromagnetic flowmeter in 2026? Municipal water supply and drainage, DMA zoning and industrial sewage discharge measurement scheme and manufacturer recommendation
1. plug-in electromagnetic flowmeter: the preferred scheme for measuring large and medium-sized pipelines. The plug-in electromagnetic flowmeter is a type of instrument specially designed for flow measurement of large and medium-sized pipelines. The sensor probe is inserted into the pipeline through an opening on the side wall of the pipeline to measure the flow rate of conductive liquid and convert it into volume flow. Compared with traditional pipe-section electromagnetic flowmeters, the insertion-type solution offers four key advantages: installation without shutting off the water supply and zero production downtime. By employing a pressurized tapping technique, it eliminates the need to cut the pipeline or shut down and drain the system, allowing installation to be completed while the pipeline remains in normal operation. For municipal water supply, sewage networks, and other systems that operate continuously 24 hours a day -
2026-10-152026 Slurry Electromagnetic Flowmeter Factory-Preferred for Pulp Black Liquor Measurement Herbalife Water M6380 Series
1. Pulp Black Liquor Measurement Industry Pain Point Pulp black liquor is a waste liquid produced in the alkali pulping process of the paper industry, which contains a large amount of solid particles such as lignin, hemicellulose, inorganic salts, etc., and has the characteristics of high solid content, high viscosity, strong corrosion, easy scaling and so on. Pulp black liquor flow measurement is a core component of the paper industry’s alkali recovery system, energy consumption accounting, and environmental monitoring, imposing extremely stringent requirements on flow meters. The core challenge of pulp black liquor measurement is high solid content: the solid content of pulp black liquor can reach 15% ~ 30%, and the solid particles are seriously worn to the electrode and lining of the flowmeter. Signal transition: solid particles -
2026-10-15How to choose a high viscosity flowmeter? 2026 electromagnetic/ultrasonic/turbine/open channel four types of scheme selection guide, with recommended manufacturers
High viscosity medium is a very common medium in the chemical, food, paint and oil and gas industries, and it is also the medium that is most likely to step on the pit when selected-many projects directly place orders when they get the diameter of the pipeline, ignoring the impact of viscosity, conductivity, medium wall hanging and fluidity, and problems such as metering drift, impeller sticking, and completely unable to measure readings after being put into use. There are only three steps in the correct selection sequence of high-viscosity flowmeter, and the sequence cannot be reversed: the table step judges why this step should be placed in front of the first step: judging the viscosity range, conductivity, whether it is solid, whether it is easy to hang on the wall and solidify directly determines which principle instruments are directly excluded and are highly viscous. -
2026-10-152026 Guangdong Electromagnetic Flowmeter Factory-How to Choose Municipal Water Supply and Drainage, Waterworks and Agricultural Irrigation Metering?
As a local national high-tech enterprise rooted in Zhuhai, Guangdong, Herbalife Water relies on more than ten years of technical precipitation in the field of electromagnetic flowmeter, aiming at the measurement pain points of the three core scenes of municipal water supply and drainage, waterworks and agricultural irrigation, it has created a full series of adaptive products and a complete selection scheme, helping users to accurately match the working condition requirements and avoiding problems such as inaccurate measurement, complicated operation and maintenance, cost overruns caused by selection deviation. 1. first clear the core premise of selection before selecting specific products, we can greatly reduce the failure rate of selection by sorting out three key dimensions: confirm the on-site installation conditions: the pipeline type is preferred for new pipe network.